Install the ferrule (1) and the dielectric (2) on the wire.
-
Install the contact (3) on the core and crimp with the applicable tool.
-
Install the dielectric (4) over the contact (3).
-Engage this assembly in the connector body (5). Make sure that the shoulder of the ferrule touches the rear of the connector.
-Crimp the connector body (5) with the applicable tool. Make sure that the crimping is in the crimping area.
20-44-37 Page 4
Miniature Type Coaxial Connectors - Crimping Procedure
E0180-T
Figure 003
20-44-37 Page 5
Miniature Type Coaxial Connectors - Crimping Procedure
E0180-W
Figure 004
20-44-37 Page 6
_____________________________3. NSA938012 and NSA938013 plugs
(Ref. Fig. 005)
A. P/N identification
NSA938012 2B
NSA938013 3B
| |
| ---------------- Type Code
-------------------------- Standard P/N
B. P/N characteristics
(1) Type code (Ref. Fig. 006) 2B = Contact with two bayonets 3B = Contact with three bayonets 3BT = Contact 3B + 2B adaptor (only for NSA938013)
20-44-37 Page 7
Miniature Type Coaxial Connectors - Layout
NSA938012 and NSA938013
Figure 005
20-44-37 Page 8
Miniature Type Coaxial Connectors - Type Codes
NSA938012 and NSA938013
Figure 006
20-44-37 Page 9
C. Connection Procedure
(1) With normal wire (AC or CF type)
(a)
Wire stripping
(Ref. Fig. 007)
(b)
Crimping procedure
(Ref. Fig. 005, 007)
-Slide the ferrule (1) on the wire.
-Strip the wire at the size "A".
-Slide the dielectric (2) on the wire. Slide the contact core (3) on the wire conductor.
-Crimp the contact core (3) with the tool.
-Engage the assembly into the connector body, positioning the rear of the barrel against the ferrule (1).
-Crimp the barrel of the contact body (4).
20-44-37 Page 10
Miniature Type Coaxial Connectors - Stripping, Crimping Tools for Normal Wires
NSA938012 and NSA938013
Figure 007
20-44-37 Page 11
(2) With coaxial wire
(a) Wire stripping (Ref. Fig. 008)
-Strip the wire at the length "A" and "B" with the appropriate tool.
(b) Crimping procedure (Ref. Fig. 008)
-Slide on to the cable the ferrule (1).
Open the braided shield.
-Turn the braiding over the ferrule (1) with the braided shield on both sides.
-Slide the dielectric (2) over the cable and the wire conductor.
-Crimp the contact core (3) with the tool.
-Introduce the assembly into the connector body, positioning the rear of the barrel against the ferrule (1).
-Crimp the barrel of the contact body (4) with the tool.
20-44-37 Page 12
Miniature Type Coaxial Connectors - Stripping, Crimping Tools for Coaxial Wires
NSA938012 and NSA938013
Figure 008
20-44-37 Page 13
______________________________________________________________
COAXIAL CONNECTORS - MISCELLANEOUS - DESCRIPTION AND OPERATION
_______
1. General Miscellaneous coaxial connectors installed on aircraft have the codes that follow:
-E0295
_____
2. E0295
(Ref. Fig. 001)
A. P/N identification
E0295 PL 01 FL | | | | | | | -------------- Bayonet code | None = 3 bayonets | | | | FL = 4 bayonets | | | | | ------------------- Code cable | 01 = E0259 | | | ------------------------ Type code | PL = plug | | BJ = socket | ------------------------------- Standard P/N
B. Connection procedure
(1)
Wire stripping
(Ref. Fig. 002)
-Put the cap, the heat shrinkable sleeve (1) on the wire before you strip it to prevent the deformation of the braided shield.
-Strip the wire to the size A. Make sure that you do not cut the braided shield strands or cause damage to the conductors.
(2)
Crimping procedure
(Ref. Fig. 003)
(a) Open the braided shield.
-Install the braid cone under the braid (2), (3). Put the two wires through the cone (2) and make sure that the braid (3) touches the cone support (2).
(b)
Install the dielectric (4) and make sure that the white wire (6) goes through the center of the dielectric (4) and the brown wire
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 ESPM Electrical Standard Practices Manual 3(55)