Pressure Seal - Grommet Type - Cavity Arrangements E0073 R Figure 004
20-43-41 Page 11
Pressure Seal - Grommet Type - Cavity Arrangements E0073 R Figure 005
20-43-41 Page 12
Pressure Seal - Grommet Type - Cavity Arrangements E0073 R Figure 006
20-43-41 Page 13
Pressure Seal - Grommet Type - Cavity Arrangements E0073 R Figure 007
20-43-41 Page 14
Pressure Seal - Grommet Type - Cavity Arrangements E0073 R Figure 008
20-43-41 Page 1520-43-41 Page 1620-43-41 Page 17
R (4) Wire addition procedure
R - Remove the sealing plug from unused cavity.
R - Insert the wire to be added in accordance with the wire
R installation procedure.
R (5) Wire replacement procedure
R - Cut the wire to be replaced on each side of the pressure seal.
R - Install a shrinkable sleeve or end cap on each end of the wire.
R - Remove the sealing plug from unused cavity.
R - Add the new wire through the unused cavity in accordance with the
R wire installation procedure.
R - If no cavities are available, cut and remove the wire to be
R replaced and insert the new wire.
_______________________3. Fireproof Pressure Seal
R A. ABS0634
R (1) P/N identification
R (Ref. Fig. 009)
R ABS0634 - A
R | |
R | ------------- Type code
R --------------------- Standard P/N
R (2) P/N characteristics
R (a) Temperature
R Continuous operating temperature is 200 deg.C (392.00 deg.F).
R Resistance to fire is 1100 deg.C (2012.00 deg.F) for 20 mn.
R (b) Cavity arrangements
R (Ref. Fig. 009)
R B. ABS0681
(1) P/N identification
ABS0681 - 01
| |
R | ------------ Type code
R --------------------- Standard P/N
(2) P/N characteristics
(a) Temperature
Minimum operating temperature is -65 deg.C (-85.00 deg.F).
Maximum operating temperature is 260 deg.C (500.00 deg.F).
(b) Cavity arrangements
R (Ref. Fig. 010)
R C. E0739
(1) P/N identification
E0739 -01
| |
R | ------------ Type code
R --------------------- Standard P/N
R Fireproof Pressure Seal - Grommet Type - Cavity Arrangement R ABS0634 R Figure 009
20-43-41 Page 18
Fireproof Pressure Seal - Grommet Type - Cavity Arrangements ABS0681 R Figure 010
20-43-41 Page 19
(2) P/N characteristics
(a) Temperature Continuous operating temperature is -65 deg.C (-85.00 deg.F) to 200 deg.C (392.00 deg.F). Peak operating temperature is 300 deg.C (572.00 deg.F). Resistance to fire 1100 deg.C (2012.00 deg.F) for 20 mn.
(b) Cavity arrangement R (Ref. Fig. 011)
20-43-41 Page 20
Fireproof Pressure Seal - Grommet Type - Cavity Arrangement E0739 R Figure 011
20-43-41 Page 2120-43-41 Page 22
R D. NSA934501 (2 passages)
R R (1) P/N identification NSA934501 - 02 | | | ------------ Type code --------------------- Standard P/N
(2) P/N characteristics
(a) Temperature Continuous operating temperature is 200 deg.C (392.00 deg.F). Peak operating temperature is 300 deg.C (572.00 deg.F). Resistance to fire 1100 deg.C (2012.00 deg.F) for 20 mn.
R (b) Cavity arrangements (Ref. Fig. 012)
R E. NSA934502 (13 passages)
R R (1) P/N identification NSA934502 - 13 | | | ------------ Type code --------------------- Standard P/N
(2) P/N characteristics
(a) Temperature Continuous operating temperature is 200 deg.C (392.00 deg.F). Peak operating temperature is 300 deg.C (572.00 deg.F). Resistance to fire 1100 deg.C (2012.00 deg.F) for 20 mn.
R (b) Cavity arrangements (Ref. Fig. 012)
R F. NSA934504 (4 passages)
R R (1) P/N identification NSA934504 - 01 | | | ------------ Type code --------------------- Standard P/N
Fireproof Pressure Seal - Grommet Type - Cavity Arrangements NSA934501, NSA934502 and NSA934504 R Figure 012
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 ESPM Electrical Standard Practices Manual 3(10)