R Annunciator Light - P/N Characteristics, Connection Arrangement, Torque Values R E0070 (ex NSA933610) R Figure 001
20-45-12 Page 3
R Annunciator Light - P/N Characteristics, Connection Arrangement, Torque Values R E0071 (ex NSA933613) R Figure 002
20-45-12 Page 420-45-12 Page 5
R (b) Connection arrangement
R (Ref. Fig. 002)
R (3) Connection procedure
R For connection procedure (Ref. Connection Table paragraph).
R C. E0123 (ex NSA931919)
R (Ref. Fig. 003)
(1) P/N identification
E0123 7 2 1 0
NSA931919 | | | |
| | | | ------------- Modification code
| | | ----------------- Assembly code
R | | --------------------- Connection arrangement code
| ------------------------- Coil voltage code
---------------------------------- Standard P/N
(2) P/N characteristics
R (a) Connection arrangement
R (Ref. Fig. 003)
R (3) Connection procedure
R For connection procedure (Ref. Connection Table paragraph).
R D. E0216 (ex NSA931920)
R (Ref. Fig. 004)
(1) P/N identification
R E0216 - 1 - 0
R NSA931920 - 2 - 0
R | | |
R | | --------------------- Sealing code
R | ------------------------- Size code
R ---------------------------------- Standard P/N
(2) P/N characteristics
R (a) Connection arrangement
R (Ref. Fig. 004)
R (3) Connection procedure
R For connection procedure (Ref. Connection Table paragraph).
R Annunciator Light - P/N Characteristics, Connection Arrangement, Torque Values R E0123 (ex NSA931919) R Figure 003
20-45-12 Page 6
R Annunciator Light - P/N Characteristics, Connection Arrangement, Torque Values R E0216 (ex NSA931920) R Figure 004
20-45-12 Page 720-45-12 Page 8
E. E0307
R (Ref. Fig. 005)
(1) P/N identification
E0307 B 4 0 B
| | | | |
| | | | ------------- Diagram code
R | | | ----------------- Front face protection code : 0 = Matt black
R | | --------------------- Indicator color code in fault detection :
R | | 4 = Yellow
R | ------------------------- Indicator color code : B = Black
------------------------------ Standard P/N
(2) P/N characteristics
(a) Temperature
Minimum operating temperature is -40 deg.C (-40.00 deg.F)
Maximum operating temperature is 85 deg.C (185.00 deg.F)
R (3) Connection procedure
R For connection procedure (Ref. Connection Table paragraph).
R
R - Red = + 28V
R - Black = Fault input
R - Yellow = Test input
R - White = Test shunt
R - Green = Reset input (28V)
R - Purple = Reset shunt
R - Blue = Bonding input
R F. E0423 and E0457
R (Ref. Fig. 006)
(1) P/N identification
R E0423 - 01 E
R E0457 - 01 E
R | | |
R | | --------------------- Sealing code
R | ------------------------- Body identifier
R ------------------------------- Standard P/N
(2) P/N characteristics
(a) Temperature
Minimum operating temperature is -35 deg.C (-31.00 deg.F)
Maximum operating temperature is 70 deg.C (158.00 deg.F)
R Annunciator Light - P/N Characteristics and Torque Values R E0307 R Figure 005
20-45-12 Page 9
R Annunciator Light - P/N Characteristics, Connection Arrangement, Torque Values R E0423 and E0457 R Figure 006
20-45-12 Page 1020-45-12 Page 11
R (b) Connection arrangement
R (Ref. Fig. 006)
R (3) Connection procedure
R For connection procedure (Ref. Connection Table paragraph).
G. E0595
R (Ref. Fig. 007)
(1) P/N identification
E0595 A 03 A 06
| | | | |
| | | | ---------Wire length code
| | | ---------------- Wire gage code
| | -------------------- Lens color code
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 ESPM Electrical Standard Practices Manual 3(71)