 Figure 010


20-44-31 Page 16
 Oct 01/04
R


 BNC Type Coaxial Connectors - Wire Stripping and Crimping Tools
 NSA938603
 Figure 011


20-44-31 Page 17
 Oct 01/04
R


 BNC Type Coaxial Connector - Crimping Procedure
 NSA938603, NSA938604 and NSA938608
 Figure 012

 

20-44-31 Page 18

 _______________________________________________________
COAXIAL CONNECTORS - C TYPE - DESCRIPTION AND OPERATION
 _______
1. General C type coaxial connectors installed on aircraft have the codes that follow:
 -E0463
 -NSA938661
 _______________________2. E0463 Coaxial connector
 A. P/N identification
 (Ref. Fig. 001)
 E0463 F 02

 | | |
R | | ---------- Wire type code | 01 : E0293XF
R | | | 02 : E0406WD or E0692WN
 | | | ---------------- Type code | F : Right receptacle | | FC : Right angle plug | ----------------------- Standard P/N
 B. P/N Characteristics
 (1) Temperature Minimum operating temperature is -65 deg.C (-85.00 deg.F). Maximum operating temperature is 165 deg.C (329.00 deg.F)
 C. Connection procedure
 (1)
 Wire stripping
 (Ref. Fig. 002)


 -Put the heat shrinkable sleeve then the ferrule on the wire before you strip it to prevent the deformation of the shield braid.
 -Strip the wire to the length A and B. Make sure that you do not cut the shield braid strands or cause damage to the center conductor.

 (2)
 Crimping procedure
 (Ref. Fig. 003)

 

 -Make sure that the heat shrinkable sleeve and the ferrule are in position on the wire.
 -
Crimping of ferrule. Install the cap on the braid support. Move the braid support below the braid. Install the ferrule on the braid and crimp with the applicable tool. Cut the braid on the flange level cap.

 -
Crimping of contact and assembly.

 


20-44-32 Page 1

R C Type Coaxial Connectors - Layout E0463 Figure 001


20-44-32 Page 2

R C Type Coaxial Connectors - Wire Stripping and Crimping Tools E0463 Figure 002


20-44-32 Page 3

R C Type Coaxial Connectors - Crimping Procedure R E0463
 Figure 003


20-44-32 Page 420-44-32 Page 5

 Strip the wire to length "C". Install the insulating washer then engage the wire core in the contact, until the core insulation touches the contact. Crimp with the applicable tool. - Install the assembly in the connector body. - Tighten the cap to the applicable torque. - Make a red line on the connector body and the cap to show that it is tight. - Install the heat shrinkable sleeve.
 - Shrink the sleeve to let the red line stay apparent.
 D. Associated items : 
R R  Coaxial adapter : ABS0910 and ABS1333 (these items are used to transform E0463 with a threaded locking system).
R  (1) P/N identification (Ref. Fig. 004) ABS0910 - 01 
R  ABS1333 - 01 
R R R  | | | ----------- Item code No ------------------- Standard P/N
R  (2) P/N characteristics 
R  (a) Temperature : Minimum operating temperature is -55 deg.C (-67.00 deg.F). For ABS0910: 
R R  Maximum operating temperature is 165 deg.C (329.00 deg.F) For ABS1333: 
R  Maximum operating temperature is 155 deg.C (311.00 deg.F)
R R  ____NOTE : These types of adapters are used to connect a N type connector (E0462) with a C type connector (E0463).
 _________3. NSA938661
 A. P/N identification (Ref. Fig. 005) NSA938661 F 04
 | | | | | --------- Wire type code | | | --------------- Type code | F : Right receptacle | | P : Right plug | | FC : Right angle plug | | TC : Square flange bulkhead connector | | TR : round flange bulkhead connector | ------------------------ Standard P/N

 


R C Type Coaxial Connectors - Associated Items for E0463 R ABS0910 and ABS1333
 Figure 004


20-44-32 Page 6

R C Type Coaxial Connectors - Layout R NSA938661 R Figure 005


20-44-32 Page 720-44-32 Page 8

R  B. P/N Characteristics 
R  (1) Temperature 
R  Minimum operating temperature is -54 deg.C (-65.20 deg.F). 
R  Maximum operating temperature is 200 deg.C (392.00 deg.F) 
R  C. Connection procedure 
R  (1) Wire stripping 
R  (Ref. Fig. 006) 
R  - Put the ferrule on the wire before you strip it to prevent the 
R  deformation of the shield braid. 
R  - Strip the wire. Make sure that you do not cut the shield braid 
 