 A. P/N Identification R (Ref. Fig. 003)
 (1) For complete connector:
 ABS0831  D  G  01A  91 XX | | | | | | | | | | | ------ Variant code | | | | ------------ Polarization code | | | ----------------- Contact configuration code | | --------------------- Connector type code | G = Unsealed with | | | ground contacts | | | H = Sealed with | | | ground contacts | | | | | A = E0161 | ------------------------ Basic connector code | C = E0163 | | D = E0165 ------------------------------ Standard P/N
 (2) For components:
 ABS0831  MK 01 | | | | | ---------- Version code | --------------- Component type code | MK = Polarization key, male | | RP = Retention plate | | FK = Polarization key, female | | BB = Fixing screws for signal | | retention plate | | WW = Spring washers for fixing | | screws --------------------- Standard P/N
 B. P/N characteristics
 (1)
 Variant code No code : Delivery with signal contacts and ground contacts

 X : Delivery only with ground contacts

 (2)
 Polarization system
 (Ref. Fig. 003, 004)

 

 

20-44-22 Page 4

R ARINC 600 Connectors - P/N Identification and Connector Configuration ABS0831 Figure 003


20-44-22 Page 520-44-22 Page 620-44-22 Page 7

 


R  (3) Polarization setting - Remove the two screws that attach the key retention plate. - Put the polarization keys in the correct position for connector coding (refer to the polarization table). - Put the key retention plate in position. - Install the two screws that attach the key retention plate. - TORQUE the two screws to between 0.02 m.daN (1.7699 lbf.in) and 0.04 m.daN (3.5398 lbf.in) with a torque screwdriver. 
R R  C. Contact configurations 
R  (Ref. Fig. 005, 006, 007) 
R R  D. Contact arrangements Refer to para: contact arrangements

 


R ARINC 600 Connectors - Contact Configuration & Contact Arrangement Codes ABS0831, E0161 and E0165 Figure 005


20-44-22 Page 8

R ARINC 600 Connectors - Contact Configuration & Contact Arrangement Codes ABS0831 and E0163 Figure 006


20-44-22 Page 9

R ARINC 600 Connectors - Contact Configuration & Contact Arrangement Codes R ABS0831 and E0163 R Figure 007


20-44-22 Page 1020-44-22 Page 11

 __________________________________________________________4. E0161, E0163 and E0165 plugs - E0162 and E0164 receptacles
R  A. P/N identification (Ref. Fig. 008) E0161 D 01 A 01 X E0162 | | | | E0163 | | | |__________ Variant code E0164 | | | E0165 | | ------------------ Polarization code | | --------------------------- Contact configuration code | ------------------------------------ Class code -------------------------------------------- Standard P/N
 B. P/N characteristics
 (1) Temperature Minimum operating temperature is -65 deg.C (-85.00 deg.F) Maximum operating temperature is +125 deg.C (+257.00 deg.F)
 (2) Variant code X = without contacts No code = with contacts
R  (3) Polarization system (Ref. Fig. 008, 009)
R  (4) Polarization setting - Remove the two screws that attach the key retention plate. - Put the keys in the correct position for connector coding (refer to the polarization table). - Put the polarization key retention plate in position. - Install the two screws that attach the key retention plate. - TORQUE the two screws to between 0.02 m.daN (1.7699 lbf.in) and 0.04 m.daN (3.5398 lbf.in) with a torque screwdriver. 
R R R  C. Contact configurations (Ref. Fig. 005, 006, 007) 
R R  D. Contact arrangements Refer to para: contact arrangements

 


R ARINC 600 Connectors - P/N Identification and Connector Configuration E0161, E0163 and E0165
R Figure 008


20-44-22 Page 12

R ARINC 600 Connectors - Polarization System E0161, E0163 and E0165
R Figure 009


20-44-22 Page 13

R ____________________
5.
 Contact arrangements R (Ref. Fig. 010, 011, 012, 013)

 ________________

6.
 Connection Table R (Ref. Fig. 014)

 


20-44-22 Page 14

R ARINC 600 Connectors - Contact Arrangements ABS0084, ABS0831, E0161, E0163 and E0165 R Figure 010


20-44-22 Page 15

R ARINC 600 Connectors - Contact Arrangements R ABS0831, E0163 and E0165 R Figure 011


20-44-22 Page 16

R ARINC 600 Connectors - Contact Arrangements ABS0831, E0163 and E0165
R Figure 012


20-44-22 Page 17

R ARINC 600 Connectors - Contact Arrangements R ABS0831, E0163 and E0165 R Figure 013


20-44-22 Page 18

R ARINC 600 Connectors - Connection Table R Figure 014


20-44-22 Page 19
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn