X : Delivery only with ground contacts
(2)
Polarization system
(Ref. Fig. 003, 004)
20-44-22 Page 4
R ARINC 600 Connectors - P/N Identification and Connector Configuration ABS0831 Figure 003
20-44-22 Page 520-44-22 Page 620-44-22 Page 7
R (3) Polarization setting - Remove the two screws that attach the key retention plate. - Put the polarization keys in the correct position for connector coding (refer to the polarization table). - Put the key retention plate in position. - Install the two screws that attach the key retention plate. - TORQUE the two screws to between 0.02 m.daN (1.7699 lbf.in) and 0.04 m.daN (3.5398 lbf.in) with a torque screwdriver.
R R C. Contact configurations
R (Ref. Fig. 005, 006, 007)
R R D. Contact arrangements Refer to para: contact arrangements
R ARINC 600 Connectors - Contact Configuration & Contact Arrangement Codes ABS0831, E0161 and E0165 Figure 005
20-44-22 Page 8
R ARINC 600 Connectors - Contact Configuration & Contact Arrangement Codes ABS0831 and E0163 Figure 006
20-44-22 Page 9
R ARINC 600 Connectors - Contact Configuration & Contact Arrangement Codes R ABS0831 and E0163 R Figure 007
20-44-22 Page 1020-44-22 Page 11
__________________________________________________________4. E0161, E0163 and E0165 plugs - E0162 and E0164 receptacles
R A. P/N identification (Ref. Fig. 008) E0161 D 01 A 01 X E0162 | | | | E0163 | | | |__________ Variant code E0164 | | | E0165 | | ------------------ Polarization code | | --------------------------- Contact configuration code | ------------------------------------ Class code -------------------------------------------- Standard P/N
B. P/N characteristics
(1) Temperature Minimum operating temperature is -65 deg.C (-85.00 deg.F) Maximum operating temperature is +125 deg.C (+257.00 deg.F)
(2) Variant code X = without contacts No code = with contacts
R (3) Polarization system (Ref. Fig. 008, 009)
R (4) Polarization setting - Remove the two screws that attach the key retention plate. - Put the keys in the correct position for connector coding (refer to the polarization table). - Put the polarization key retention plate in position. - Install the two screws that attach the key retention plate. - TORQUE the two screws to between 0.02 m.daN (1.7699 lbf.in) and 0.04 m.daN (3.5398 lbf.in) with a torque screwdriver.
R R R C. Contact configurations (Ref. Fig. 005, 006, 007)
R R D. Contact arrangements Refer to para: contact arrangements
R ARINC 600 Connectors - P/N Identification and Connector Configuration E0161, E0163 and E0165
R Figure 008
20-44-22 Page 12
R ARINC 600 Connectors - Polarization System E0161, E0163 and E0165
R Figure 009
20-44-22 Page 13
R ____________________
5.
Contact arrangements R (Ref. Fig. 010, 011, 012, 013)
________________
6.
Connection Table R (Ref. Fig. 014)
20-44-22 Page 14
R ARINC 600 Connectors - Contact Arrangements ABS0084, ABS0831, E0161, E0163 and E0165 R Figure 010
20-44-22 Page 15
R ARINC 600 Connectors - Contact Arrangements R ABS0831, E0163 and E0165 R Figure 011
20-44-22 Page 16
R ARINC 600 Connectors - Contact Arrangements ABS0831, E0163 and E0165
R Figure 012
20-44-22 Page 17
R ARINC 600 Connectors - Contact Arrangements R ABS0831, E0163 and E0165 R Figure 013
20-44-22 Page 18
R ARINC 600 Connectors - Connection Table R Figure 014
20-44-22 Page 19
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 ESPM Electrical Standard Practices Manual 3(41)