|-------------------------- Standard P/N
(2) P/N characteristics
(a)
Temperature Minimum operating temperature is : -65 deg.C (-85.00 deg.F). Maximum operating temperature is : 125 deg.C (257.00 deg.F).
(b)
Contact arrangement code and contact arrangement Refer to para : Contact Arrangement Code
-Refer to the contact arrangement code table which gives equivalence between standard contact arrangement code and manufacturer contact arrangement code.
-This contact arrangement code is used to select the applicable contact arrangement.
(c)
Polarization keys To determine the polarization code, refer to Para : Polarization Device.
(d)
Contact allocation For normal contact and coaxial contact allocation, refer to Para : Contact Allocation.
20-44-21 Page 13
Apr 01/04
R
D. E0122, NSA938331 and NSA938332 Connectors (Two Gang Shell - ARINC 404)
(1) P/N identification
E0122 G S G S 3 01 -
NSA938331 | | | | | | |
NSA938332 | | | | | | |- Variant code | E = Sealed version
| | | | | | | | (-) Dash = Unsealed version
| | | | | | |
| | | | | | |--- Polarization code
| | | | | |
| | | | | |------ Shell code | 0 = Standard holes
| | | | | | 3 = Adjusting holes 100.CSK
| | | | |
| | | | |
| | | | |--------- Type of contact | P = Pin
| | | | | S = Socket
| | | |
| | | |------------- Contact arrangement code = Side B
| | |
| | |----------------- Type of contact | P = Pin
| | | S = Socket
| |
| |--------------------- Contact arrangement code = Side A
|
|------------------------------ Standard P/N
(2) P/N characteristics
(a)
Temperature Minimum operating temperature is : -55 deg.C (-67.00 deg.F). Maximum operating temperature is : 125 deg.C (257.00 deg.F).
(b)
Contact arrangement code and contact arrangement Refer to para : Contact Arrangement Code
-Refer to the contact arrangement code table which gives equivalence between standard contact arrangement code and manufacturer contact arrangement code.
-This contact arrangement code is used to select the applicable contact arrangement.
(c)
Polarization keys To determine the polarization code, refer to Para : Polarization Device.
(d)
Contact allocation For normal contact and coaxial contact allocation, refer to Para : Contact Allocation.
20-44-21 Page 14
Apr 01/04
R
E. E0086 and E0147 Connectors (Two gang shell - MIL-C-81659)
E0086 H S H S 0 A 01
E0147 | | | | | | |
| | | | | | | |- Polarization code