F 『 EEFF : ALL E Page B41671-51-43
E E May 01/04 ERE
ECES E 5. Close-up
F 『
E C F M E
E E
E 56-5B E
E E
________ Subtask 71-51-43-862-059
A. De-energize the aircraft circuits (Ref. TASK 24-41-00-862-002) Subtask 71-51-43-410-062
B. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the fan cowls: (Ref. TASK 71-13-00-410-040)
FOR 1000EM1
437AL, 438AR
FOR 1000EM2
447AL, 448AR
(3) Remove the access platform(s).
(4) Remove the warning notice(s).
F 『 EEFF : ALL E Page B41771-51-43
E E May 01/04 ERE
ECES E
F 『
E C F M E
E E
E 56-5B E
E E
ELECTRICAL HARNESS - CORE ZONE - REMOVAL/INSTALLATION
_____________________________________________________
TASK 71-52-43-000-042
Removal of the Core Fire Detector Channel A Wire Harness (4204KS)
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific blanking caps
No specific circuit breaker(s) safety clip(s)
No specific warning notice
No specific access platform 1.5 m (4 ft. 11 in.)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
71-13-00-010-040 Opening of the Fan Cowl Doors
78-30-00-481-041 Make the Thrust Reverser Unserviceable for
Maintenance
78-36-00-010-040 Opening of the Thrust Reverser Doors
R **ON A/C 001-049, 051-099, 101-149, 151-155, 157-199, 201-299, 301-399, R 401-499,
71-52-43-991-303 Fig. 401
**ON A/C 156-156,
71-52-43-991-303-A Fig. 401A
F 『 EEFF : ALL E Page 40171-52-43
E E Aug 01/05 E E ECES E **ON A/C ALL
F 『
E C F M E
E E
E 56-5B E
E E
3. Job Set-up
__________
Subtask 71-52-43-860-054
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a warning notice to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a warning notice to tell persons not to energize the FADEC 1(2).
Subtask 71-52-43-865-056
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU ENGINE/2/FIRE DET/LOOP B 8WD2 A07 49VU ENGINE/1/FIRE DET/LOOP A 7WD1 A06 49VU ENGINE/2/FADEC A/AND EIU 2 2KS2 A05 49VU ENGINE/1/FADEC A/AND EIU 1 2KS1 A04 49VU ENGINE/1 AND 2/IGN/SYS A 1JH A03 49VU ANTI ICE/PROBES/AOA/1 4DA1 D04 49VU ANTI ICE/PROBES/PHC/1 2DA1 D03 49VU ANTI ICE/PROBES/PITOT/1 3DA1 D02 49VU COM/CVR/SPLY 2RK E14 49VU COM/CVR/CTL 4RK E13 49VU NAV PROBES/ADIRU 1/AND AOA 1/26VAC 5FP1 F07 49VU NAV PROBES/ADIRU1/115VAC 4FP1 F06
F 『 EEFF : ALL E Page 40271-52-43
E E May 01/05 ERE
ECES E -------------------------------------------------------------------------------
F 『
E C F M E
E E
E 56-5B E
E E
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R **ON A/C 001-049, 051-052, 054-056, 058-059, 061-099, 101-101, 103-149,
R 151-199, 201-299, 301-399, 401-499, Post SB 30-1037 For A/C 001-049,051-052,054-056,
49VU ANTI ICE/RAIN/RPLNT/CAPT 1DB1 D01
**ON A/C ALL
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 动力装置 POWER PLANT 2(72)