 (2) Put the access platform in position.

 F 『 EEFF : ALL E Page A41471-51-43
 E E May 01/05 ERE
ECES E

 F 『
 E C F M E
 E E
 E 56-5B E
 E E


 4. Procedure
_________
 (Ref. Fig. 411/TASK 71-51-43-991-306)
 Subtask 71-51-43-020-059
 A. Removal of the ECU (Channel A) to Thrust Reverser Junction Box Harness (4213KS).
 NOTE : To open the flip-lock clamps and line blocks, turn the captive
____ screws or captive bolts 1/4 turn counterclockwise to disengage the cam nuts.
R NOTE : Loosely attach the clamp(s), anti-rotation lug(s) if applicable,
____ R and bolt(s) to the brackets from which they were removed to make R it easier for installation.
 (1) Disconnect the electrical connector 4007VC-A from the harness
 junction box. R R BEFORE SPIB NO. CFM02255MW1 R
 (2) Open the line blocks (10), (15) and (20) that attach the harness (5)
 to the brackets. R R AFTER SPIB NO. CFM02255MW1 R (Ref. Fig. 411/TASK 71-51-43-991-306) R
R (3) Open the line blocks (10), (15) and (20) that attach the harness (5) R to the brackets.
R (4) Remove the clamps and bolts (12) that attach the harness to the R bracket.
R (5) Remove the clamps and bolts (17) that attach the harness to the R bracket.
R (6) Remove the clamps, bolt and anti-rotation lug (18) that attach the R harness (5) to the bracket. R R END SPIB NO. CFM02255MW1 R
R (7) If necessary, remove the rubber supports from the line blocks.
 F 『 EEFF : ALL E Page A41571-51-43
 E E Feb 01/04 E E ECES E F 『 E C F M E E E E 56-5B E F 『 E C F M E E E E 56-5B E F 『 EEFF : ALL E Page A41871-51-43

 

R R  Lower Right Fan Zone Electrical Harness Figure 411/TASK 71-51-43-991-306- 12 (SHEET 1)
 F EEFF : E E ECES  ALL  『E 71-51-43EEE Page A416 Feb 01/04

 


R R  Lower Right Fan Zone Electrical Harness Figure 411/TASK 71-51-43-991-306- 22 (SHEET 2)
 F EEFF : E E ECES  ALL  『E 71-51-43EEE Page A417 Feb 01/04


 F  『
 E  C F M  E
 E  E
 E  56-5B  E
 E  E 


R  (8) Remove the harness (5) from the rubber supports. 
R  (9) Disconnect the electrical connector 4000KS-J5 from the ECU. 
R  (10) Put protective covers on the electrical connectors. 
R  (11) Remove the electrical harness (5) from the engine.

 E E Feb 01/04 E E ECES E

 F 『
 E C F M E
 E E
 E 56-5B E
 E E


 TASK 71-51-43-400-049
 Installation of the ECU (Channel A) to Thrust Reverser Junction Box Harnesses (4213KS)
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific warning notice
 No specific access platform 1 m (3 ft. 3 in.)
R No specific Torque Wrench : range 5.00 to 35.00 lbf.in
R (0.05 to 0.40 m.daN)
 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
 from the External Power
 31-60-00-860-001 EIS Start Procedure
 31-60-00-860-002 EIS Stop Procedure
 70-60-00-910-041 Nacelle Maintenance Practices
 71-13-00-010-040 Opening of the Fan Cowl Doors
 71-13-00-410-040 Closing of the Fan Cowl Doors
 78-31-00-710-042 Operational Test of the Thrust Reverser System
 71-51-43-991-306 Fig. 411

 F 『 EEFF : ALL E Page A41971-51-43
 E E May 01/05 E E ECES E

 F 『
 E C F M E
 E E
 E 56-5B E
 E E


 3. Job Set-up
__________
 Subtask 71-51-43-860-071
 A. Aircraft Maintenance Configuration
 (1) On the center pedestal, on the ENG panel 115VU, make sure that a warning notice is in position to tell persons not to start the engine.

 (2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a warning notice is in position to tell persons not to energize the FADEC 1(2).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 动力装置 POWER PLANT 2(46)