• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-27 12:57来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

R  **ON A/C 001-049, 051-052, 054-056, 058-059, 061-099, 101-101, 103-149,
R  151-199, 201-299, 301-399, 401-499, Post SB 30-1037 For A/C 001-049,051-052,054-056,
 122VU ANTI ICE/RAIN/RPLNT/F/O  1DB2 W11
 **ON A/C ALL
 123VU Y HYD/ELEC/PUMP  3802GX AB06
 123VU Y HYD/ELEC/ELEC PUMP/NORM  3801GX AB03
 FOR 1000EM1 49VU ENGINE/1/FIRE DET/LOOP A 7WD1 A06 49VU ENGINE/1/FADEC A/AND EIU 1 2KS1 A04
 121VU ENGINE/IGN/ENG1/SYS B 3JH1 P41 121VU ENGINE/IGN/ENG1/SYS A BAT 2JH1 P39 121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B 2WE1 Q44
 F 『 EEFF : ALL E Page 40971-51-43
 E E Aug 01/05 E E ECES E

 F  『
 E  C F M  E
 E  E
 E  56-5B  E
 E  E


 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A 1WE1 Q43 121VU ENGINE/ENG1/FIRE DET/LOOP B 8WD1 Q38 121VU ENGINE/ENG1/FADEC B/AND EIU 1 4KS1 R41 122VU ELEC/GCU/1 2XU1 T26
 FOR 1000EM2 49VU ENGINE/2/FIRE DET/LOOP B 8WD2 A07 49VU ENGINE/2/FADEC A/AND EIU 2 2KS2 A05 121VU ENGINE/IGN/ENG2/SYS B 3JH2 P42 121VU ENGINE/IGN/ENG2/SYS A BAT 2JH2 P40 121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B 2WE2 Q42 121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A 1WE2 Q41 121VU ENGINE/ENG2/FADEC B 4KS2 Q40 121VU ENGINE/ENG2/FIRE DET/LOOP A 7WD2 Q39 122VU ELEC/GCU/2 2XU2 T27
 4. Procedure_________
 (Ref. Fig. 401/TASK 71-51-43-991-300, 402/TASK 71-51-43-991-301)
 Subtask 71-51-43-420-053
 A. Installation of the Generator Power Harness
 NOTE : For the recommended procedure for the installation of the wire
____
 harness (Ref. TASK 70-60-00-910-041)>.

 (1) Remove the protective covers from the electrical connectors on the harness (5) and the pylon junction box.

 (2) Make sure that the electrical connectors are clean and in the correct condition.

 (3) Do not clean the contacts with abrasive material.

 (4) Put the electrical harness (5) in position on the engine.

 (5) Connect the electrical connector 400VC-A to the pylon junction box.


 (a) Tighten the connector by hand until the colored marking is visible in the lock display (window).
 F 『 EEFF : ALL E Page 41071-51-43
 E E May 01/05 ERE
ECES E

 F  『
 E  C F M  E
 E  E
 E  56-5B  E
 E  E


 (6) Put the harness (5) into the clamps (10). Make sure that the harness is correctly installed on the engine.

 (7) Tighten the captive screws 1/4 turn clockwise to engage the cam nuts.

 (8) Clean the mating surfaces:


 WARNING : TRICHLOROETHANE IS A HAZARDOUS MATERIAL THAT CAN CAUSE
_______ INJURY OR ILLNESS IF NOT CORRECTLY USED. BEFORE YOU USE THIS PRODUCT, READ THE APPLICABLE MANUFACTURER'S "MATERIAL DATA SAFETY SHEET" AND OBEY THE SAFETY AND HEALTH PRECAUTIONS.
 (a) Clean the mating surfaces of the ground cable terminals and the bracket with 1,1,1, trichloroethane (Material No. CP11-002) and a lint-free cloth.
 (9) Attach the harness cables (5) tothe bracket with the bolt (30), the lockwasher (15), the washer (25), and the nut (20). Remove the tags.
 (10) TORQUE the nut (20) to between 95 and 110 lbf.in (1.07 and 1.24 m.daN).

 (11) Attach the harness cables (50), (55), (60) and (65) to the IDG terminals with the washers (45), the lockwashers (40) and the nuts (35).

 (12) TORQUE the nuts (35) to between 144 and 168 lbf.in (1.62 and 1.89 m.daN).

 (13) Install the cover (75) on the IDG terminal with the CFMI supplied screws (70).

 (14) TORQUE the screws (70) to between 20 and 22 lbf.in (0.22 and 0.24 m.daN).

 (15) Do an electrical bond resistance check as follows:


 NOTE : The electrical bond resistance procedure that follows is
____ applicable for the electrical harness ground cables.
 (16) Put one lead of the ohmmeter on the ground cable terminal near the bolt (30).

 (17) Put the other lead of the ohmmeter on the top surface of the bracket.


 F 『 EEFF : ALL E Page 41171-51-43
 E E May 01/04 ERE ECES E

 F  『
 E  C F M  E
 E  E
 E  56-5B  E
 E  E


 (18) The resistance measured between the ohmmeter leads must not be more than 0.001 ohm.

 (19) If the resistance is more than 0.001 ohm, remove the applicable hardware and clean the mating surfaces again. Do this procedure until the resistance is less than 0.001 ohm.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 动力装置 POWER PLANT 2(18)