• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-25 23:58来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (4)
 Connect an AC voltmeter (minimum range: 0-20V, accuracy: 1 mV, frequency: 50-2000 Hz) to the SECONDARY VOLTAGE connections on the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST (18).

 (5)
 Make sure that the CBs of the BSCU SYS2 (3GG and 4GG) are open.

 (6)
 On panel 402VU, put the A/SKID & N/W STRG switch in ON position.


 1EFF : 001-004, 051-054, 1 32-51-00Page 558 1 1 Aug 01/05R 1 1 1CES 1


 (7)
 Stage 4:

 (a)
 On the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST

 (18) set the selector switch to U1.

 (b)
 Record the voltage (U1)(in AC voltage).

 (c)
 On the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST

 (18) set the selector switch to U2.

 (d)
 Record the voltage (U2)(in AC voltage).

 (e)
 Calculate the algebraic value U:
 U = (U1 - U2)

 


 (8)
 On panel 402VU, put the A/SKID & N/W STRG switch in OFF position.

 (9)
 Remove the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST


 (18) from the sensor 4GC. Subtask 32-51-00-820-051
 D. Set the NWS Zero Position for the sensor 3GC
 (1)
 On panel 402VU, make sure that the A/SKID & N/W STRG switch in OFF position.

 (2)
 Disconnect the connector (19) from the RVDT 3GC (16).

 (3)
 Connect the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST (F26792000-1) (18) between the connector (19) and the RVDT 3GC (16).

 (4)
 Connect an AC voltmeter (minimum range: 0-20V, accuracy: 1 mV, frequency: 50-2000 Hz) to the SECONDARY VOLTAGE connections on the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST (18).

 (5)
 Make sure that the CBs of the BSCU SYS2 (3GG and 4GG) are open.

 (6)
 On panel 402VU, put the A/SKID & N/W STRG switch in ON position.

 (7)
 Stage 5:

 (a)
 On the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST

 (18) set the selector switch to U1.

 (b)
 Record the voltage (U1)(in AC voltage).

 


 1EFF : 001-004, 051-054, 1 32-51-00Page 559 1 1 Aug 01/05R 1 1 1CES 1


 (c)
 On the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST

 (18) set the selector switch to U2.

 (d)
 Record the voltage (U2)(in AC voltage).

 (e)
 Calculate the algebraic value B:
 B = (U1 - U2)

 

 (8)
 On panel 402VU, put the A/SKID & N/W STRG switch in OFF position.

 (9)
 Remove the RVDT 3GC (16) (Ref. TASK 32-51-19-000-001).


 (10)
 On the ADJUSTING TOOL - NWS GEARBOX (F26630200) (13), loosen the two knurled adjusters (14) so that the inner part of the ADJUSTING TOOL -NWS GEARBOX (13) can turn freely.

 (11)
 Install the ADJUSTING TOOL - NWS GEARBOX (13) on the N/WS gearbox


 (10)
 -put the stud (22) of the ADJUSTING TOOL - NWS GEARBOX (13) in the drive slot (23) of the gearbox plate (12),
 -attach the ADJUSTING TOOL - NWS GEARBOX (13) on the gearbox (10) with the screws (15).
 NOTE : Fully tighten the screws (15) on the tool before you attach it
____
 on the gearbox (10).

 (12) Install the RVDT 3GC (16) (Ref. TASK 32-51-19-400-001)
 -engage the spigot (20) in the hole (21) on the ADJUSTING TOOL - NWS GEARBOX (13),
 -make sure that it is flush with the N/WS gearbox (13). NOTE : Lightly lubricate the packing of the sensor 3GC with COMMON
____
 GREASE (Material No. 04-015).

 (13)
 Connect the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST (F26792000-1) (18) to the RVDT 3GC (16).

 (14)
 On panel 402VU, put the A/SKID & N/W STRG switch in ON position.

 (15)
 Stage 6:

 (a)
 On the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST

 (18) set the selector switch to U1.

 (b)
 Record the voltage (U1)(in AC voltage).

 


 1EFF : 001-004, 051-054, 1 32-51-00Page 560 1 1 Aug 01/05R 1 1 1CES 1


 (c)
 On the SENSOR-VOLTAGE TEST (F26792000) or SENSOR - VOLTAGE TEST

 (18) set the selector switch to U2.

 (d)
 Record the voltage (U2)(in AC voltage).

 (e)
 Calculate the algebraic value C:
 C = (U1 - U2)

 

 (16)
 On panel 402VU, put the A/SKID & N/W STRG switch in OFF position.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM LANDING GEAR 起落架8(94)