 TASK 10-12-00-200-008

 

 Periodic ground-check at 1-month interval
 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________

 A. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 05-043 VARNISH P.T.F.E SPRAY (Ref. 20-31-00) Material No. 15-002 USA MIL-B-131 TYPE I BARRIER MATERIAL WATER VAPOR PROOF (Ref. 20-31-00)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R
R R R
12-32-28-281-001 12-32-28-281-003 12-32-28-281-004 21-26-00-710-001 21-28-00-710-006 21-28-00-720-003 24-41-00-861-002 24-41-00-862-002 28-11-00-600-004 28-11-00-600-004 28-11-00-600-004
Drain Water ContentSample Fuel for Microbiological Contamination AnalysisFuel Sampling for a Microbiological Contamination Test with a Microb Monitor Test Kit (OBSOLETE)Operational Check of System via MCDUOperational Test of the AFT Cargo-Compartment Ventilation-SystemFunctional Test of the FWD Cargo-Compartment Ventilation-SystemEnergize the Aircraft Electrical Circuits from the External PowerDe-energize the Aircraft Electrical Circuits Supplied from the External PowerBiobor Biocidal Shock Treatment - With Fuel Mixed with Biocide Additive (OBSOLETE)Kathon Biocidal Shock Treatment - With Fuel Mixed with Biocide Additive (OBSOLETE)Biobor Biocidal Shock Treatment - When Fuel Mixed with Biocide Additive is not Available (OBSOLETE) -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------

 


28-11-00-600-004 R 28-11-00-600-007 R 28-11-00-600-007 R 28-11-00-600-007 R 28-11-00-600-007 R 28-24-00-710-002
30-11-00-710-001 30-21-00-710-001 52-10-00-010-001 52-10-00-410-001 52-22-00-010-001
52-22-00-410-001
52-30-00-860-001
52-30-00-860-002
52-30-00-860-006 52-30-00-860-008
3. Job Set-up
__________
Kathon Biocidal Shock Treatment - When Fuel Mixed with Biocide Additive is not Available (OBSOLETE)Introduce Biobor Biocide into Fuel - With Fuel Mixed with Biocide Additive (OBSOLETE)Introduce Kathon Biocide into Fuel - With Fuel Mixed with Biocide Additive (OBSOLETE)Introduce Biobor Biocide into Fuel - When Fuel Mixed with Biocide Additive is not Available (OBSOLETE)Introduce Kathon Biocide into Fuel - When Fuel Mixed with Biocide Additive is not Available (OBSOLETE)Operational Test of the ENG 1(2) LP Fuel Valve 12QM (13QM)Operational Test of the Wing Ice-Protection SystemOperational Test of the Anti Ice System Fault WarningOpening of the Passenger/Crew DoorClosing of the Passenger/Crew DoorOpening of the Emergency Exit Doors from the Passenger CompartmentClosing of the Emergency Exit Doors from the Passenger CompartmentOpen the FWD or AFT Cargo-Compartment Door with the Yellow Electric PumpClose the FWD or AFT Cargo-Compartment Door with the Yellow Electric PumpOpen the Bulk Cargo-Compartment DoorClose the Bulk Cargo-Compartment Door


R **ON A/C 001-003, 051-054,
 Subtask 10-12-00-010-060-A
 A. Get Access
 (1)
 Open the passenger/crew doors (Ref. TASK 52-10-00-010-001).

 (2)
 Open the FWD and AFT cargo-compartment doors (Ref. TASK 52-30-00-860-001).

 (3)
 Open the emergency exit doors (Ref. TASK 52-22-00-010-001).

 


 (4) Open the bulk cargo-compartment door (Ref. TASK 52-30-00-860-006). R **ON A/C 004-049, 055-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 Subtask 10-12-00-010-060
 A. Get Access
 (1)
 Open the passenger/crew doors (Ref. TASK 52-10-00-010-001).

 (2)
 Open the FWD and AFT cargo-compartment doors (Ref. TASK 52-30-00-860-001).


 (3) Open the emergency exit doors (Ref. TASK 52-22-00-010-001).
 **ON A/C ALL

 Subtask 10-12-00-860-063
 B. Aircraft Configuration
 (1)
 Remove the STORAGE PRESERVATION (Material No. 15-002) and adhesive tape from :

 -
the avionics ventilation system inlets and outlets (15HQ and 22HQ)

 -
the outflow valve (10HL).

 

 (2)
 Energize the aircraft electrical circuits from the external power (Ref. TASK 24-41-00-861-002).

 (3)
 On the overhead panel 25VU, on the CABIN PRESS section:


 -Release the DITCHING pushbutton switch to open the avionics ventilation skin valves.
 