-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
R 98D10103501000 1 COVER - ICE DETECTION PROBE
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
10-11-00-991-001 Fig. 202
R **ON A/C 401-499,
R 10-11-00-991-001-A Fig. 202A
R **ON A/C ALL
10-11-00-991-004 10-11-00-991-005 10-11-00-991-006 Fig. 203Fig. 204Fig. 205
3. Job Set-up__________
Subtask 10-11-00-941-056
A. Safety Precautions
(1) Put an ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position near the aircraft.
(2) Put a WARNING NOTICE in position in the cockpit to tell persons not to operate the systems while you install the protective devices on the aircraft.
4. Procedure_________
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
Subtask 10-11-00-555-069
A. Installation of the Protection Devices on the Fuselage (Ref. Fig. 202/TASK 10-11-00-991-001)
(1) Protection of the 2 total temperature sensors - Put the COVER - SLIP-ON, TOTAL TEMPERATURE SENSOR (98A10001013000) in position.
(2) Protection of the 3 pitot probes - Put the COVER - SLIP-ON PITOT PROBE (98A10001005000) in position.
(3) Protection of the 3 angle-of-attack sensors - Put the COVER - SLIP-ON, ANGLE OF ATTACK SENSOR (98A10001500000) or COVER - SLIP-ON, AOA (98D10003003000) in position.
(4) Protection of the 6 static probes - Put the COVER-STATIC PROBE (98D10103500001) in position.
R **ON A/C 401-499,
R Subtask 10-11-00-555-069-A
R R A. Installation of the Protection Devices on the Fuselage (Ref. Fig. 202A/TASK 10-11-00-991-001-A)
R R R (1) Protection of the 2 total temperature sensors - Put the COVER - SLIP-ON, TOTAL TEMPERATURE SENSOR (98A10001013000) in position.
R R (2) Protection of the 3 pitot probes - Put the COVER - SLIP-ON PITOT PROBE (98A10001005000) in position.
R R R (3) Protection of the 3 angle-of-attack sensors - Put the COVER - SLIP-ON, ANGLE OF ATTACK SENSOR (98A10001500000) or COVER - SLIP-ON, AOA (98D10003003000) in position.
R R (4) Protection of the 6 static probes - Put the COVER-STATIC PROBE (98D10103500001) in position.
Protective Equipment
Figure 202/TASK 10-11-00-991-001
R EFF : 001-049, 051-099, 101-149, 151-199, 10-11-00Page 243 201-299, 301-399, Aug 01/05 CES
R Protective Equipment
R Figure 202A/TASK 10-11-00-991-001-A
R EFF : 401-499, 10-11-00 Page 244
Aug 01/05
CES
R (5) Protection of the 2 ice detection probes
R - Put the COVER - ICE DETECTION PROBE (98D10103501000) in position.
R **ON A/C ALL
Subtask 10-11-00-555-070
B. Installation of the Protection Devices on the Engines (Ref. Fig. 203/TASK 10-11-00-991-004, 204/TASK 10-11-00-991-005)
(1)
Protection of the engine air intakes
-Put the COVER - INLET COWL ENGINE (RSE1244) or COVER - INLET COWL ENGINE (98D10003002000) in position.
(2)
Protection of the engine exhaust nozzles
-Put the COVER - COMMON NOZZLE (RSE1132) in position.
(3)
Protection of the thrust reverser opening
-Put the HALF PLUG, RIGHT-THRUST REVERSER (HIX6002) and HALF PLUG, LEFT-THRUST REVERSER (HIX6003) in position.
Subtask 10-11-00-555-071
C. Installation of the Protection Devices on the APU Area
(Ref. Fig. 205/TASK 10-11-00-991-006)
(1)
Protection of the APU exhaust duct
-Put the COVER - EXHAUST DUCT, APU (98D10007512000) in position.
(2)
Protection of the outlet duct of the APU oil cooler
-Put the COVER - OILCOOLER OUTLET, APU (98D10007513000) in position.
5. Close-up
________
Subtask 10-11-00-942-058
A. Close-up
(1) Remove all the fixtures, tools, test and support equipment used during this procedure.
Protective Equipment Figure 203/TASK 10-11-00-991-004
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM PARKING, MOORING, STORAGE & RETURN TO S(16)