____ completed.
(6) Close all the fuel system valves.
STORAGE - MAINTENANCE PRACTICES_______________________________
R TASK 10-12-00-553-005
R Storage Procedures
R 1. Reason for the Job__________________
R This task gives the procedures for:
R - storage of the aircraft for a period of not more than 6 months
R - storage of the aircraft for a period of not more than 2 years
R - ground checks during storage
R - return to operation after storage
R - renewal of storage procedure
R 2. Job Set-up Information______________________
R A. Referenced Information
R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------
R 10-12-00-200-006 Periodic Ground Check at 7-day Intervals
R 10-12-00-200-007 Periodic Ground Check at 15-day Intervals
R 10-12-00-200-008 Periodic ground-check at 1-month interval
R 10-12-00-200-009 Periodic ground-check at 3-month interval
R 10-12-00-200-010 Periodic Ground Check at 6-month Intervals
R 10-12-00-553-006 Storage Procedure (Storage Not More than 6 Months)
R 10-12-00-553-007 Storage Procedure (Storage Not More than 2 Years)
R 10-12-00-553-008 Renewal for 6 Months Storage Period
R 10-12-00-553-009 Renewal for 2 Years Storage Period
R 10-30-00-554-005 Return to Operation after Storage Period
R 3. Job Set-up__________
R Subtask 10-12-00-860-058
R A. Not Applicable
R 4. Procedure
_________
R Subtask 10-12-00-553-068
R A. Procedure to store the aircraft with related procedures to do perodic
R ground checks, return to operation and renew the storage procedure
R (1) Storage procedure for a period of not more than 6 months (Ref. TASK
R 10-12-00-553-006)
R (a) During the storage period of not more than 6 months, you must do
R periodic ground checks:
R - at 7-day intervals (Ref. TASK 10-12-00-200-006)
R - at 15-day intervals (Ref. TASK 10-12-00-200-007)
R - at 1-month interval (Ref. TASK 10-12-00-200-008)
R - at 3-month intervals (Ref. TASK 10-12-00-200-009).
R (b) Return to operation after a storage period (Ref. TASK 10-30-00-
R 554-005).
R (c) You can do again the procedure to store the aircraft not more
R than six months one time only (Ref. TASK 10-12-00-553-008).
R (2) Storage procedure for a period not more than 2 years (Ref. TASK 10-
R 12-00-553-007).
R (a) During storage period not more than 2 years, you must do perodic
R ground-checks:
R - at 7-day intervals (Ref. TASK 10-12-00-200-006).
R - at 15-day intervals (Ref. TASK 10-12-00-200-007).
R - at 1-month interval (Ref. TASK 10-12-00-200-008).
R - at 3-month intervals (Ref. TASK 10-12-00-200-009).
R - at 6-month intervals (Ref. TASK 10-12-00-200-010).
R (b) Return to operation after a storage period (Ref. TASK 10-30-00-
R 554-005).
R (c) The procedure to store the aircraft 2 years can be renewed
R (Ref. TASK 10-12-00-553-009).
R TASK 10-12-00-553-006
R Storage Procedure (Storage Not More than 6 Months)
R CAUTION : MAKE SURE THAT YOU OBEY THE MAINTENANCE PROGRAM FOR STORED/ PARKED_______
R AIRCRAFT. DO NOT CHANGE OR STOP THE MAINTENANCE PROGRAM WITHOUT
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM PARKING, MOORING, STORAGE & RETURN TO S(20)