the rudder bearings No. 6 (Ref. TASK 12-22-55-640-001)
-
the trimmable horizontal stabilizer bearings and attachment fittings (Ref. TASK 12-22-53-640-001)
-
the roller bearings of the flap tracks (Ref. TASK 12-22-27-640-004)
-
the roller and the pinion bearings of the slat tracks (Ref. TASK 12-22-27-640-006)
-all the spoiler servo-control bearings (Ref. TASK 12-22-27-640-005).
-
the slat tracks surface with OILS (Material No. 03-001)
-
the flap rotary actuators (Ref. TASK 12-22-27-640-008).
(2)
Clean and protect the flight control cables (Ref. TASK 20-24-11-100-001).
Subtask 10-12-00-620-084
F. Protection of the fuel system
(1)
Do a fuel sampling for microbiological contamination (Ref. TASK 12-32-28-281-003) or (Ref. TASK 12-32-28-281-004).
(2)
If you find contamination:
(a) Do a shock treatment :
-
if fuel premixed with biocide is available (Ref. TASK 28-11-00-600-004) or (Ref. TASK 28-11-00-600-004)
-
if fuel premixed with biocide is not available (Ref. TASK 28-11-00-600-004) or (Ref. TASK 28-11-00-600-004).
EFF : ALL 10-12-00Page 240 May 01/05R CES
(b) Do a preventive treatment:
1_ If fuel premixed is available:
- Refuel the wing tanks to 90% of the total capacity with fuel
premixed with biocide (Ref. TASK 28-11-00-600-007) or
(Ref. TASK 28-11-00-600-007)
- Refuel the center tank to 30% of the total capacity with
fuel premixed with biocide (Ref. TASK 28-11-00-600-007) or
(Ref. TASK 28-11-00-600-007)
2_ If fuel premixed is not available:
- Refuel the wing tanks to 90% of the total capacity with fuel
not premixed with biocide (Ref. TASK 28-11-00-600-007) or
(Ref. TASK 28-11-00-600-007)
- Rrefuel the center tank to 30% of the total capacity with
fuel not premixed with biocide (Ref. TASK 28-11-00-600-007)
or (Ref. TASK 28-11-00-600-007)
(3)
If you do not find contamination:
(a)
If fuel premixed with biocide is available:
-
Refuel the wing tanks to 30% of the total capacity with fuel premixed with biocide (Ref. TASK 28-11-00-600-007) or (Ref. TASK 28-11-00-600-007)
-
Refuel the center tank to 30% of the total capacity with fuel premixed with biocide (Ref. TASK 28-11-00-600-007) or (Ref. TASK 28-11-00-600-007).
(b)
If fuel premixed with biocide is not available:
-
Refuel the wing tanks to 30% of the total capacity with fuel not premixed (Ref. TASK 28-11-00-600-007) or (Ref. TASK 28-11-00-600-007)
-
Refuel the center tank to 30% of the total capacity with fuel not premixed with biocide (Ref. TASK 28-11-00-600-007) or (Ref. TASK 28-11-00-600-007).
(4)
Drain water from all the fuel tanks (Ref. TASK 12-32-28-281-001)
NOTE : Do the water drain procedure one hour after refueling is
____ completed.
(5) Close all the fuel system valves.
R EFF : ALL 10-12-00Page 241 May 01/05 CES
Subtask 10-12-00-620-085
G. Protection of the Engines
(1) For a period up to 30 days, do the preservation of the engines (Ref. TASK 72-00-00-600-006).
(2) For a period up to 90 days, do the preservation of the engines (Ref. TASK 72-00-00-600-025).
(3) For a period of 90 days to one year, do the preservation of the engines (Ref. TASK 72-00-00-600-007).
(4) Do the IDG on wing preservation.
R **ON A/C 001-049, 101-105, 151-199, 201-210,
Subtask 10-12-00-620-086-A
H. Protection of the APU
(1) Do the preservation of the APU (Ref. TASK 49-20-00-600-003).
(2) If necessary, apply SPECIAL MATERIALS (Material No. 05-027) on cases, solenoids, brackets, screws and bolt heads in the APU compartment.
R **ON A/C 051-099,
R Subtask 10-12-00-620-086-B
R H. Protection of the APU
R R (1) Do an inspection of the APU for preservation (Ref. TASK 49-20-00-200-001).
R (2) Do the preservation of the APU (Ref. TASK 49-20-00-600-001).
R R (3) If necessary, apply SPECIAL MATERIALS (Material No. 05-027) on cases, solenoids, brackets, screws and bolt heads in the APU compartment.
R EFF : ALL 10-12-00Page 242 May 01/05 CES
R **ON A/C 106-149, 211-299, 301-399, 401-499, 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM PARKING, MOORING, STORAGE & RETURN TO S(34)