(2)
Flush the static pressure line of the Air Data Module (Ref. TASK 34-10-00-170-002).
(3)
Drain and flush the standby static and standby total pressure lines of the Air Data Module (Ref. TASK 34-10-00-170-003).
R EFF : ALL 10-11-00Page 233 May 01/05 CES R **ON A/C 106-149, 213-213, 221-299, 301-399, 401-499,
Subtask 10-11-00-170-054-A
F. Flushing of the Air Data System
NOTE : Flush the Air Data System only if the parking period is more than
____
2 Days
(1)
Flush the total pressure line of the Air Data Module (Ref. TASK 34-10-00-170-001).
(2)
Flush the static pressure line of the Air Data Module (Ref. TASK 34-10-00-170-002).
(3)
Drain and flush the standby static and standby total pressure lines of the Air Data Module (Ref. TASK 34-22-25-170-001).
**ON A/C 001-003, 051-054,
Subtask 10-11-00-010-055-A
G. Get Access
(1) Open and closed all the access doors to the pressurized area and make sure that they operate correctly :
-
the AFT and FWD passenger/crew doors (Ref. TASK 52-10-00-010-001) and (Ref. TASK 52-10-00-410-001)
-
the FWD and AFT cargo compartments (Ref. TASK 52-30-00-860-002) and (Ref. TASK 52-30-00-860-002)
-
the bulk cargo-compartment door (Ref. TASK 52-30-00-860-006) and (Ref. TASK 52-30-00-860-008)
R EFF : 001-003, 051-054, 106-149, 213-213, 10-11-00Page 234 221-299, 301-399, 401-499, Aug 01/05 CES
R **ON A/C 004-049, 055-099, 101-149, 151-199, 201-299, 401-499,
Subtask 10-11-00-010-055
G. Get Access
(1) Open and closed all the access doors to the pressurized area and make sure that they operate correctly :
-
the AFT and FWD passenger/crew doors (Ref. TASK 52-10-00-010-001) and (Ref. TASK 52-10-00-410-001)
-
the FWD and AFT cargo compartments (Ref. TASK 52-30-00-860-002) and (Ref. TASK 52-30-00-860-002)
**ON A/C 301-399,
Subtask 10-11-00-010-055-B
G. Get Access
(1) Open and closed all the access doors to the pressurized area and make sure that they operate correctly :
-
the AFT and FWD passenger/crew doors (Ref. TASK 52-10-00-010-001) and (Ref. TASK 52-10-00-410-001)
-
the emergency exit doors (Ref. TASK 52-10-00-010-001) and (Ref. TASK 52-10-00-410-001)
-
the FWD and AFT cargo compartments (Ref. TASK 52-30-00-860-002) and (Ref. TASK 52-30-00-860-002)
**ON A/C ALL
5. Close-up
________
Subtask 10-11-00-860-067
A. Close-up
(1)
De-energize the aircraft electrical circuits supplied from the external power (Ref. TASK 24-41-00-862-002).
(2)
Remove the tag from the Captain side stick or write in the log book that the protection covers/devices are no longer installed.
(3)
Remove all the fixtures, tools, test and support equipment used during this procedure.
TASK 10-11-00-555-011
R R R R R Renewal of 15-Day Parking Period
CAUTION : MAKE SURE THAT YOU OBEY THE MAINTENANCE PROGRAM FOR STORED/ PARKED
_______ AIRCRAFT. DO NOT CHANGE OR STOP THE MAINTENANCE PROGRAM WITHOUT APPROVAL FROM YOUR LOCAL AUTHORITIES.
CAUTION : DURING THIS PROCEDURE:
_______
-MAKE SURE THAT THE LANDING GEAR GROUND SAFETIES, LOCKING DEVICES AND WHEEL CHOCKS ARE IN POSITION.
-KEEP THE ACCESS PLATFORM AT A SUFFICIENT DISTANCE FROM THE AIRCRAFT (IN WIND, SHOCK ABSORBER REBOUND CAN CAUSE MOVEMENT OF THE AIRCRAFT).
1. Reason for the Job
__________________
This procedure gives the operator the possibility to do the parking
procedure of 15 days again one time.
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
10-11-00-200-003 Periodic Groung Check at 15-day Intervals 12-32-28-281-001 Drain Water Content 12-32-28-281-003 Sample Fuel for Microbiological Contamination
Analysis 12-32-28-281-004 Fuel Sampling for a Microbiological Contamination Test with a Microb Monitor Test Kit (OBSOLETE) 28-11-00-600-004 Biobor Biocidal Shock Treatment - With Fuel Mixed with Biocide Additive (OBSOLETE) 28-11-00-600-004 Kathon Biocidal Shock Treatment - With Fuel Mixed with Biocide Additive (OBSOLETE) 28-11-00-600-004 Biobor Biocidal Shock Treatment - When Fuel Mixed with Biocide Additive is not Available (OBSOLETE) 28-11-00-600-004 Kathon Biocidal Shock Treatment - When Fuel Mixed with Biocide Additive is not Available (OBSOLETE)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM PARKING, MOORING, STORAGE & RETURN TO S(14)