‐ Push the C/Bs in the following order: M05 C/B,
G02 C/B.
‐ After CIDS reset, wait approximately 4 min,
before recovering normal operation.
Frozen RMP RMP Refer to PRO-SUP-23 FROZEN RMP
23
FAP freezing FAP or Tape
reproducer/PRAM On ground, or in flight:
‐ Pull C/B M14 C/B (or Q14 ) of the FAP in the
121VU.
‐ Wait 10 s before pushing the C/B.
IF UNSUCCESSFUL:
‐ Pull the tape reproducer/PRAM C/B F07 C/B on
2000VU (cabin)
‐ Wait 10 s before pushing the C/B.
23
COM CIDS 1+2 FAULT CIDS On ground, or in flight:
‐ Pull the C/Bs in the following order:
G01 C/B on 49VU, M05 C/B on 121VU.
G02 C/B on 49VU, M06 C/B on 121VU.
‐ Wait 10 s, then
‐ Push the C/B in the following order: M05 C/B,
M06 C/B, G01 C/B, G02 C/B.
‐ After CIDS reset, wait approximately 4 min,
before recovering normal operation.
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
SUPPLEMENTARY PROCEDURES
ELECTRICAL
A318/A319/A320/A321 FLEET PRO-SUP-24 P 8/14
FCOM 19 AUG 10
Continued from previous page
ATA System malfunction or
ECAM Warning/Caution Affected System Reset
Uncommanded EVAC horn
actuation
CIDS On ground, or in flight:
Press the EVAC HORN SHUT OFF pb. Set the
EVAC CAPT & PURS/CAPT sw to the CAPT only
position. Wait for 3 s. IF UNSUCCESSFUL:
Pull the C/Bs for DIR2 in ‐ the following order: G02
C/B on 49VU, M06 C/B on 121VU.
IF UNSCCESSFUL:
‐ Pull the C/Bs for DIR1 in the following order: G01
C/B on 49VU, M05 C/B on 121VU.
‐ Wait for 1 min, then:
‐ Push the C/Bs for DIR2 in the following order:
M06 C/B, G02 C/B.
‐ After CIDS reset, wait approximately 4 min,
before recovering normal operation.
Frozen RMP RMP Refer to PRO-SUP-23 FROZEN RMP
FAP freezing FAP or Tape
reproducer/PRAM On ground, or in flight:
‐ Pull C/B M14 C/B (or Q14 ) of the FAP in the
121VU.
‐ Wait 10 s before pushing the C/B.
IF UNSUCCESSFUL:
‐ Pull the tape reproducer/PRAM C/B F07 C/B on
2000VU (cabin)
‐ Wait 10 s before pushing the C/B.
23
COM CIDS 1+2 FAULT CIDS On ground, or in flight:
‐ Pull the C/Bs in the following order:
P13 and P14 on 121VU.
M06 C/B and M07 C/B on 121VU.
G01 C/B and G02 C/B on 49 VU.
‐ Wait 10 s, then
‐ Push the C/Bs in the following order: G01 C/B,
G02 C/B, M06 C/B, M07 C/B, P13 , P14
.
After CIDS reset, wait ‐ approximately 4 min,
before recovering normal operation.
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
SUPPLEMENTARY PROCEDURES
ELECTRICAL
A318/A319/A320/A321 FLEET PRO-SUP-24 P 9/14
FCOM 19 AUG 10
Continued from previous page
ATA System malfunction or
ECAM Warning/Caution Affected System Reset
Uncommanded EVAC horn
actuation
CIDS On ground, or in flight:
Press the EVAC HORN SHUT OFF pb. Set the
EVAC CAPT & PURS/CAPT sw to the CAPT only
position. Wait for 3 s. IF UNSUCCESSFUL:
‐ Pull the C/Bs for DIR2 in the following order: G02
C/B on 49VU, M07 C/B on 121VU.
IF UNSCCESSFUL:
‐ Pull the C/Bs for DIR1 in the following order: G01
C/B on 49VU, M06 C/B on 121VU.
‐ Wait for 1 min, then:
‐ Push the C/Bs for DIR2 in the following order:
M07 C/B, G02 C/B.
‐ After CIDS reset, wait approximately 4 min,
before recovering normal operation.
Frozen RMP RMP Refer to PRO-SUP-23 FROZEN RMP
FAP freezing FAP or Tape
reproducer/PRAM On ground, or in flight:
‐ Pull FAP C/Bs in the following order: H01 C/B on
49VU, Q14 C/B on 121VU.
‐ Wait 10 s, then
‐ Push the C/Bs in the following order: Q14 C/B,
H01.
23
COM CIDS 1+2 FAULT CIDS On ground, or in flight:
‐ Pull the C/Bs in the following order:
P13 and P14 on 121VU.
M05 C/B and M06 C/B on 121VU.
G01 C/B and G02 C/B on 49VU C/B.
‐ Wait 10 s, then:
‐ Push the C/Bs in the following order: G01 C/B,
G02 C/B, M05 C/B, M06 C/B, P13 , P14
.
‐ After CIDS reset, wait approximately 4 min,
before recovering normal operation.
A318/A319/A320/A321 FLIGHT CREW
OPERATING MANUAL
PROCEDURES
SUPPLEMENTARY PROCEDURES
ELECTRICAL
A318/A319/A320/A321 FLEET PRO-SUP-24 P 10/14
FCOM 19 AUG 10
Continued from previous page
ATA System malfunction or
ECAM Warning/Caution Affected System Reset
Uncommanded EVAC horn
actuation
CIDS On ground, or in flight:
Press the EVAC HORN SHUT OFF pb. Set the
EVAC CAPT & PURS/CAPT sw to the CAPT only
position. Wait for 3 s. IF UNSUCCESSFUL: