(3)
Move the flexible duct away from the check valve.
S 034-006
S 034-007
S 034-008
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù.
GUN 001-010, 101-104 ú 21-26-02
ú ú 12 Page 401 ú Jan 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
SEE A
CLAMP
(2 LOCATIONS)
NO. 1 CHECK VALVE
FLEX DUCT
DUCT SUPPORT NO. 1 FAN
NO. 2 CHECK
VALVE FLOW
FLOW
NO. 2 FAN
AFT EQUIPMENT VENTILATION CHECK VALVE A
Aft Equipment Ventilation Check Valve Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù.
GUN 001-010, 101-104 ú 21-26-02
ú ú 03 Page 402 ú Dec 20/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
S 024-009
(4)
Remove the check valve.
S 434-010
(5)
Put a cover on the duct opening.
TASK 21-26-02-404-011
3. Install the Ventilation Check Valve (Fig. 401)___________________________________
A. References
(1)
AMM 06-46-00/201, Entry, Service and Cargo Doors Access Doors and Panels
(2)
AMM 24-22-00/201, Electric Power Control
B.
Access
(1)
Location Zones
165 Area aft of bulk cargo compartment (Left)
C.
Install the check valve
S 034-012
(1)
Remove the cover from the duct opening.
S 034-013
(2)
Make sure there is no unwanted material in the duct.
S 424-014
(3)
Put the check valve in position in the duct.
(a)
Make sure the flow arrow points forward.
(b)
Make sure the shaft of the check valve is in a vertical position.
S 434-015
(4)
Move part of the flexible duct on to the aft end of the check valve.
S 434-016
(5)
Install the clamp on the aft end of the check valve.
(a)
Tighten the clamp to 20-25 pound inches.
S 434-017
(6)
Install the clamp that holds the check valve to the support bracket.
D.
Do the installation test for the check valve
(1)
Supply electrical power (AMM 24-22-00/201).
S 864-019
(2)
If the No. 1 check valve was installed:
(a)
Do the steps that follow:
S 864-018
1) Remove the DO-NOT-CLOSE tag and close this circuit breaker, on the right miscellaneous electrical equipment panel, P37: a) 37D5, AFT EQPT COOLING FAN EXH NO. 1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù.
GUN 001-010, 101-104 ú 21-26-02
ú ú 12 Page 403 ú Jan 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
2) Open this circuit breaker, on the miscellaneous electrical equipment panel, P70, and attach a DO-NOT-CLOSE tag: a) 70B2, AFT EQPT COOLING FAN EXH NO. 2
(b) Make sure the No. 1 fan comes on.
S 864-020
(3)
If the No. 2 check valve was installed:
(a)
Do the steps that follow:
1) Remove the DO-NOT-CLOSE tag and close this circuit breaker, on the miscellaneous electrical equipment panel, P70: a) 70B2, AFT EQPT COOLING FAN EXH NO. 2
2) Open this circuit breaker, on the right miscellaneous electrical equipment panel, P37, and attach a DO-NOT-CLOSE tag: a) 37D5, AFT EQPT COOLING FAN EXH NO. 1
(b) Make sure the No. 2 fan comes on.
S 214-021
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 空调 AIR CONDITIONING 1(82)