• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-20 07:49来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

Remove the clamp from the aft end of the check valve.

 (3)  
Move the flexible duct away from the check valve.


 S 034-006
 S 034-007
 S 034-008
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù.
 GUN 001-010, 101-104 ú  21-26-02
 ú ú 12 Page 401 ú Jan 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

SEE  A 
CLAMP 
(2 LOCATIONS) 
NO. 1 CHECK VALVE 
FLEX DUCT 
DUCT SUPPORT  NO. 1 FAN
NO. 2 CHECK 
VALVE  FLOW 
FLOW 

NO. 2 FAN
AFT EQUIPMENT VENTILATION CHECK VALVE A
Aft Equipment Ventilation Check Valve Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù.
 GUN 001-010, 101-104 ú 21-26-02
 ú ú 03 Page 402 ú Dec 20/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
 S 024-009
 (4)  
Remove the check valve.

 S 434-010

 (5)  
Put a cover on the duct opening.


 TASK 21-26-02-404-011
 3.  Install the Ventilation Check Valve (Fig. 401)___________________________________
 A.  References
 (1)  
AMM 06-46-00/201, Entry, Service and Cargo Doors Access Doors and Panels

 (2)  
AMM 24-22-00/201, Electric Power Control

 B.  
Access

 (1)  
Location Zones
 165 Area aft of bulk cargo compartment (Left)


 C.  
Install the check valve


 S 034-012
 (1)  
Remove the cover from the duct opening.

 S 034-013

 (2)  
Make sure there is no unwanted material in the duct.

 S 424-014

 (3)  
Put the check valve in position in the duct.

 (a)  
Make sure the flow arrow points forward.

 (b)  
Make sure the shaft of the check valve is in a vertical position.


 S 434-015
 (4)  
Move part of the flexible duct on to the aft end of the check valve.

 S 434-016

 (5)  
Install the clamp on the aft end of the check valve.

 (a)  
Tighten the clamp to 20-25 pound inches.


 S 434-017
 (6)  
Install the clamp that holds the check valve to the support bracket.

 D.  
Do the installation test for the check valve

 (1)  
Supply electrical power (AMM 24-22-00/201).

 S 864-019

 (2)  
If the No. 1 check valve was installed:

 (a)  
Do the steps that follow:


 S 864-018
 1)  Remove the DO-NOT-CLOSE tag and close this circuit breaker, on the right miscellaneous electrical equipment panel, P37: a) 37D5, AFT EQPT COOLING FAN EXH NO. 1
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù.
 GUN 001-010, 101-104 ú  21-26-02
 ú ú 12 Page 403 ú Jan 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

 2)  Open this circuit breaker, on the miscellaneous electrical equipment panel, P70, and attach a DO-NOT-CLOSE tag: a) 70B2, AFT EQPT COOLING FAN EXH NO. 2
 (b) Make sure the No. 1 fan comes on.
 S 864-020
 (3)
If the No. 2 check valve was installed:

 (a)
Do the steps that follow:


 1)  Remove the DO-NOT-CLOSE tag and close this circuit breaker, on the miscellaneous electrical equipment panel, P70: a) 70B2, AFT EQPT COOLING FAN EXH NO. 2
 2)  Open this circuit breaker, on the right miscellaneous electrical equipment panel, P37, and attach a DO-NOT-CLOSE tag: a) 37D5, AFT EQPT COOLING FAN EXH NO. 1
 (b) Make sure the No. 2 fan comes on.
 S 214-021
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 空调 AIR CONDITIONING 1(82)