(2)
24-22-00/201, Electric Power Control
(3)
36-00-00/201, Pneumatic General
B.
Access
(1)
Location Zones
211/212 Control Cabin - Section 41
C.
Procedure
S 864-002
(1)
Supply electrical power (AMM 24-22-00/201)
S 864-003
(2)
For removal of the captain's shoulder heater, set the captain's shoulder heater selector on the captain's auxiliary instrument forward panel, P13, to OFF.
S 864-004
(3)
For removal of the first officer's shoulder heater, set the first officer's heater selector on the first officer's instrument forward panel, P14, to OFF.
S 864-005
(4)
Put the left and right pack control selector on the pilot's overhead panel, P5, to OFF and attach a DO-NOT-OPERATE tag.
S 864-006
(5)
For the removal of the captain's shoulder heater, open these circuit breakers on relay panel, P70, and attach DO-NOT-CLOSE tags:
(a)
70A5, CAPT AUX HTR LO
(b)
70A6, CAPT AUX HTR HI
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-45-02
ALL ú ú 01 Page 401 ú May 20/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
Shoulder Air Supply Heater - Installation
Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-45-02
ALL ú ú 01 Page 402 ú Jun 20/90
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
S 864-008
(6)
For removal of the first officer's shoulder heater, open these circuit breakers on the right miscellaneous relay panel, P37, and attach DO-NOT-CLOSE tags:
(a)
37F4, HEATERS F/O AUX HI
(b)
37F3, HEATERS F/O AUX LO
S 014-009
(7)
Open the applicable access door (116AR, 115AL or 113AL) and find the shoulder heater (AMM 06-41-00/201).
S 034-010
(8)
Disconnect the electrical connector.
S 034-011
(9)
Loosen the middle support clamp that attaches the shoulder heater to the structure.
S 034-012
(10)
Remove the two clamps that attach the shoulder heater to the duct.
S 034-013
(11)
Move the sleeve and flexible duct away from the shoulder heater.
S 024-014
(12)
Remove the shoulder heater
TASK 21-45-02-404-015
3. Install the Shoulder Air Supply Heater (Fig. 401)
______________________________________
A. References
(1)
06-41-00/201, Fuselage Access Doors and Panels
(2)
24-22-00/201, Electric Power Control
(3)
36-00-00/201, Pneumatic General
B.
Access
(1)
Location Zones
211/212 Control Cabin - Section 41
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-45-02
ALL ú ú 01 Page 403 ú May 20/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
C. Procedure
S 424-016
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 空调 AIR CONDITIONING 1(156)