(a)
Open this circuit breaker and attach DO-NOT-CLOSE tag:
1) On the right miscellaneous electrical equipment panel, P37: a) 37D5, AFT EQPT COOLING FAN EXH NO. 1
S 864-003
(2)
Do the steps that follow to remove the No. 2 fan (4):
(a)
Open these circuit breakers and attach DO-NOT-CLOSE tags:
1) On the miscellaneous electrical equipment panel, P70: a) 70B2, AFT EQPT COOLING FAN EXH NO. 2
S 014-004
(3)
Open the No. 2 cargo door, 822 (AMM 06-46-00/201).
S 014-005
(4)
Remove the aft bulkhead lining in the bulk cargo compartment (AMM 25-50-03/401).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
21-26-01
ALL ú ú 06 Page 401 ú Sep 20/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
4. FAN NO. 1
1. BOLT
5. ISOLATOR 4. FAN NO. 2
2.
WASHER FLOW
3.
NUT (2 LOCATIONS)
A
11. SCREW
10. WASHER
9. NUT
FLOW
7. CLAMP
VENTILATION
(4 LOCATIONS)
FANS
6. ELECTRICAL
SEE A
CONNECTOR
8. BONDING
JUMPER
14. FLEXIBLE DUCT (2 LOCATIONS)
13. BOLT
A
5. ISOLATOR FWD
2.
WASHER
3.
NUT
OUTBD
VENTILATION FANS (NO. 1 FAN INSTALLATION IS SHOWN, NO. 2 IS EQUIVALENT)
A
4. FAN NO. 1 4. FAN NO. 2 13. BOLT
2. WASHER
12. FAN
3. NUT
BRACKET
5. ISOLATOR
OUTBD
6. ELECTRICAL CONNECTOR
8. BONDING JUMPER11. SCREW
10. WASHER A-A 9. NUT
Aft Equipment Ventilation Fan Installation Figure 401
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù.
GUN 001-010, 101-104 ú 21-26-01
ú ú 08 Page 402 ú May 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
6. ELECTRICAL 1. SCREW
CONNECTOR 2. WASHER
5. CLAMP 3. NUT (2 LOCATIONS 4. SLEEVE 5. CLAMP
12. SCREW 4. SLEEVE PER FAN) 6. ELECTRICAL
2. WASHER CONNECTOR
(QTY 3)
3. NUT 7. BONDING
JUMPER
VENTILATION
DUCT A 8. CLAMP
(2 LOCATIONS)
9. FAN
9. FAN NO. 2 NO. 1
10. FAN
11. SCREW
AFT EQUIPMENT BRACKET
2. WASHER VENTILATION FANS
3. NUT SEE
A (2 LOCATIONS A PER FAN)
10. FAN INBD BRACKET
7. BONDING
JUMPER FWD
8. CLAMP (2 LOCATIONS)
AFT EQUIPMENT VENTILATION FANS
A
12. SCREW 6. ELECTRICAL
2.
WASHER (QTY 3)
CONNECTORS
3.
NUT
12. SCREW
2. WASHER (QTY 3)
9. FAN NO. 1 3. NUT
1. SCREW 9. FAN NO. 2 2. WASHER
7. BONDING 3. NUT
7. BONDINGJUMPER
(2 LOCATIONS) JUMPER
11. SCREW
2. WASHER
11. SCREW
3. NUT
2. WASHER
(2 LOCATIONS) 3. NUT (2 LOCATIONS)
10. FAN BRACKET 10. FAN BRACKET
OUTBD
A-A
Aft Equipment Ventilation Fan Installation Figure 401A
C33094
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù.
GUN 011-100, 105-999 ú 21-26-01
ú ú 12 Page 403 ú May 28/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757
MAINTENANCE MANUAL
D. GUN 001-010, 101-104;
Aft Equipment Ventilation Fan Removal (Fig. 401)
S 034-006
(1)
Disconnect the electrical connector (6) from the fan.
S 034-007
(2)
Remove the screw (11), washer (10), and nut (9) to disconnect the bonding jumper (8) from the fan.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 空调 AIR CONDITIONING 1(78)