HYD
APU YY
REC ERASE W
TEST CONF ENG EPCS
W
MCDP EXCD
AIR CONDITIONING CONTROL PANEL  EICAS MAINTENANCE PANEL
A C
Recirculation System Adjustment Test
Figure 501 (Sheet 1)

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-25-00
 ALL  ú ú 01 Page 502 ú Sep 20/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

MIX MANIFOLD (REF)
CHECK VALVE
AIRPLANE SKIN (REF)
GROUND CONDITIONED FAIRING (REF) AIR CONNECTOR
FWD
GROUND CONDITIONED AIR CONNECTOR D
LEFT RECIRCULATION AIR FAN
EXHAUST FLOW
SUPPLY FLOW
UP 
OVERBOARD 
EXHAUST VALVE 
FORWARD EQUIPMENT  FWD 
COOLING SUPPLY FANS 
VALVE POSITION  (REF) 
INDICATOR 

FORWARD EQUIPMENT COOLING EQUIPMENT
E

Recirculation System Adjustment Test
Figure 501 (Sheet 2)

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-25-00
 ALL  ú ú 01 Page 503 ú Jun 20/89
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
 (b)  
Put a DO-NOT-OPERATE tag on the selectors.

 D.
Do the Test for the Left Recirculation System


 S 865-008
 CAUTION: IF THE LEFT RECIRC FAN IS ON BUT NO AIRFLOW IS FELT AT THE MIX
_______ MANIFOLD, IMMEDIATELY PUSH THE L RECIRC FAN SWITCH-LIGHT TO THE OFF POSITION. THIS WILL PREVENT DAMAGE TO THE FAN.
 (1)  
Push the L RECIRC FAN switch-light, on the P5 panel, to the on position.

 (a)  
Make sure the ON light comes on.


 S 215-009
 (2)  
Feel for the airflow at the overboard exhaust valve (Ref 21-58-05).

 S 215-010

 (3)  
Feel for the airflow in the mix manifold.

 (a)  
Open the access panel for the ground connector, 193DL (Ref 06-41-00).

 (b)  
Open the check valve for the conditioned air (AMM 21-21-00/401).

 (c)  
Feel for the airflow in the mix manifold.


 S 865-011
 (4)  
Open this circuit breaker, on the P70 panel:

 (a)  
70C10, RECIRC FAN L


 S 215-012
 (5)
Make sure the L RECIRC FAN INOP light, on the P5 panel, comes on.

 S 215-013

 (6)  
Make sure the EICAS advisory message L RECIR FAN shows on the upper display.

 S 865-014

 (7)  
Close this circuit breaker, on the P70 panel:

 (a)  
70C10, RECIRC FAN L

 (8)  
Make sure the L RECIRC FAN INOP light goes off.

 S 215-016

 (9)  
Make sure the EICAS advisory message L RECIR FAN does not show on the upper display.

 S 865-017

 (10)
 Push the L RECIRC FAN switch-light, on the P5 panel, to the off position.

 (a)  
Make sure the INOP light comes on.

 E.
Do the Test for the Right Recirculation System


 S 215-015
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-25-00
 ALL  ú ú 02 Page 504 ú May 28/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A

757
MAINTENANCE MANUAL

 S 865-018

 CAUTION:_______ IF THE RIGHT RECIRC FAN IS ON, BUT NO AIRFLOW IS FELT AT THE
 PASSENGER CABIN OUTLET, IMMEDIATELY PUSH THE R RECIRC FAN
 SWITCH-LIGHT TO THE OFF POSITION.  THIS WILL PREVENT DAMAGE TO

 THE FAN.
 (1)  
Push the R RECIRC FAN switch-light, on the P5 panel, to the on position.

 (a)  
Make sure the ON light comes on.


 S 865-019
 (2)  
Open this circuit breaker on the P37 panel:

 (a)  
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 空调 AIR CONDITIONING 1(59)