• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-20 07:49来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (5)  
If the forward cargo compartment fire switch on the aft pilot's control stand P8 panel is ARMED, all power is interrupted to the heating flow fan.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-43-00
 ALL  ú ú 07 Page 3 ú Dec 20/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 757 MAINTENANCE MANUAL

CONTROL MODULE

Forward Cargo Heating System Schematic
Figure 2 (Sheet 1)

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH FORWARD CARGO FAN CURRENT ú

 21-43-00
 SENSOR  ú
 ú 02 ú BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.  Page 4May 28/01 

G21986
A 757 MAINTENANCE MANUAL

TO MIX MANIFOLD
G22342
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. AIRPLANES WITH FORWARD CARGO FAN CURRENT ú

 21-43-00
 SENSE RELAY  ú
 ú 02 ú BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.  Page 5May 28/01 

A

757
MAINTENANCE MANUAL

 B. Control
_______
 (1)  The forward cargo compartment heating system is a self controlled system requiring no pilot or mechanic action to place it into operation.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 21-43-00
 ALL  ú ú 04 Page 6 ú Dec 20/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
757 MAINTENANCE MANUAL
 FORWARD CARGO COMPARTMENT HEATING SYSTEM - ADJUSTMENT/TEST
__________________________________________________________
 1.  General_______
 A.  This procedure contains two tasks. The first task is an operational test of the heating system in the forward cargo compartment. The second task is a system test of the heating system in the forward cargo compartment.
 B.  The heating system in the forward cargo compartment uses a thermal switch temperature control. When the temperature in the forward cargo compartment is less than 50°F (10°), the switch closes and sends a signal to a relay. The relay controls the heater fan. When the temperature in the forward cargo compartment is 70°F (21°C), the switch disconnects the circuit to the forward cargo compartment fan relay. This stops the heat supply to the compartment.
 TASK 21-43-00-715-002
 2.  Operational Test - Forward Cargo Compartment Heating System____________________________________________________________
 A.  General
 (1)  
This test makes sure the fan and temperature control switch operate correctly.

 B.  
Equipment

 (1)  
Cooling source - ice pack - commercially
 available


 (2)  
Thermometer - range 0 to 120°F (0 to 49°C) -commercially available


 C.  
References

 (1)  
AMM 24-22-00/201, Electrical Power Control

 D.  
Access

 (1)  
Location Zones
 121/122 Forward Cargo Compartment
 211 212 Control Cabin - Section 41


 E.  
Procedure

 (1)  
Supply electrical power (AMM 24-22-00/201).

 S 865-004

 (2)  
Make sure these circuit breakers on the pilot's overhead circuit breaker panel, P11, are closed:

 (a)  
11N1, INSTRUMENT AND PANEL AISLE STAND

 (b)  
11N17, CARGO HEATER FAN FWD

 (c)  
11S15, AIR/GND SYS 1

 (d)  
11S19, AIR/GND SYS 2


 S 865-003
 S 865-006
 (3)  
Make sure this circuit breaker on the miscellaneous electrical equipment panel, P70, is closed:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 空调 AIR CONDITIONING 1(129)