(1)  
Location Zones
 153/154 Aft Cargo Compartment
 C.  
Procedure
 S 864-002
 (1)  
Open this circuit breaker on the overhead circuit breaker panel, P11, and attach a DO-NOT-CLOSE tag:
 (a)  
11N22, CARGO HEAT FAN AFT
 S 864-003
 (2)  
Open this circuit breaker on the right miscellaneous electrical equipment panel, P37, and attach a DO-NOT-CLOSE tag:
 (a)  
37C2, AFT CARGO FAN
 S 014-004
 (3)  Open the cargo door No. 2 (822) and find the aft cargo heating flow fan (AMM 06-46-00/201).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 21-44-06
 ALL  ú ú 02 Page 401 ú May 28/01 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 
MAINTENANCE MANUAL
AFT CARGO 
AFT CARGO 
HEATING 
FLOW FAN 
INTAKE GRILL 
SEE A 
SEE B 
1. FAN 
6. BOLT (2 LOCATIONS) 
A  SEE A-A 
2. CLAMP 
3.
 HOSE
4.
 CLAMP
4. CLAMP CARGO HEATING DUCT (REF) 
BONDING 
JUMPER 
(REF)
3. HOSE 
A 
2. CLAMP  EYEBOLT (REF) 
SEE A-A
5. NUT 
ELECTRICAL 
(SELF-LOCKING) CONNECTOR (REF) 
FWD 
AFT CARGO FLOW FAN A 
Aft Cargo Heating Flow Fan - Installation Figure 401 (Sheet 1) 
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 21-44-06
 ALL  ú ú 01 Page 402 ú Jun 20/90 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 
MAINTENANCE MANUAL
FAN SUPPORT  ISOLATOR (REF)  
LUG  
(REF)  
(4 LOCATIONS)  7. WASHER  
6. BOLT  8. NUT (SELF-LOCKING)  
9. BONDING JUMPER 
(REF) LUG FAN SUPPORT  
(SELF-LOCKING) 12. NUT  
11. WASHER  
FWD  10. EYEBOLT  
A-A  
(REF) INTAKE DUCT HEATING AFT CARGO  GRILL INTAKE 
WIRE FILTER 
AFT CARGO HEATING INTAKE GRILL B 
Aft Cargo Heating Flow Fan - Installation Figure 401 (Sheet 2) 
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 21-44-06
 ALL  ú ú 02 Page 403 ú Jun 20/90 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
A
757 
MAINTENANCE MANUAL
 (4)  S 014-005Remove the center bulkhead lining to get access to the fan (AMM 25-50-03/401). 
 (5)  S 034-006Remove the electrical connector from the heat fan (1). 
 (6)  S 034-007Remove the nut (5) and bonding jumper (9) from the fan (1). 
 (7)  S 034-008Remove the clamps (2 and 4) in four locations. 
 (8)  S 034-009Move the hose (3) in two locations away from the fan (1). 
 (9)  S 034-010Remove the bolts (6) from the isolators at the top fan support lugs.
 S 034-011
 (10)
 Remove the nut (12) that attaches the lower fan support lug to the eyebolt (10).
 (a)  
Remove the eyebolt washer (11) and keep it.
 S 024-012
 (11) Remove the fan (1).
 TASK 21-44-06-404-013
 3. Install the Aft Cargo Heating Flow Fan (Fig. 401)
__________________________________
 A. Equipment
 (1)  
Cooling source - ice pack, commercially
 available
 (2)  
Thermometer - hand held type, commercially
 available, range 40-80°F
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 21-44-06
 ALL  ú ú 01 Page 404 ú May 28/01 
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details. 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 AMM 飞机维护手册 空调 AIR CONDITIONING 1(147)