A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
REVERSE FLOW
SURGE CONTROL VALVE (8058KM)
associated with Fault Code Numbers (FCN) 87
- do a check of damage/leakage of the fuel supply and return lines of the SURGE CONTROL VALVE (8058KM)
(1) If there is damaged/leaking in the fuel supply and return lines:
- do a repair.
(2) If the fuel supply and return lines are OK:
- replace the SURGE CONTROL VALVE (8058KM) (Ref. AMM TASK 49-51-52-000-003) and (Ref. AMM TASK 49-51-52-400-003).
(a) If the fault continues:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and (Ref. AMM TASK 49-61-34-400-003).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page A254
201-210, Config-1 Aug 01/05 CES
R **ON A/C 001-049, 101-105, 107-107, 151-199, 201-210,
B. Do the test given in para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page A255
201-210, Config-1 Aug 01/05 CES
TASK 49-00-81-810-849
APU AUTO SHUTDOWN - CLOGGED OIL FILTER, Oil Filter clogged (onspeed) (131-9(A))
1. Possible Causes
_______________
- OIL FILTER SHOWS CLOGGED
- contamination of the MAGNETIC-DRAIN PLUG
- contamination of the GEN SCAV OIL FILTER (P5) and LUBE PUMP OIL FILTER (P9)
- APU GENERATOR (8XS)
- APU (4005KM)
- contamination of the GEN SCAV OIL FILTER and LUBE PUMP OIL FILTER
2. Job Set-up Information
______________________
R
R A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
49-90-00-810-812 Lube Pump Filter SW P9/GEN SCAV Filter SW P5 Fault
(131-9(A)) AMM 24-23-51-000-001 Removal of the APU Generator 8XS AMM 24-23-51-400-001 Installation of the APU Generator 8XS AMM 49-00-00-860-008 APU Start by External Power (131-9(A)) AMM 49-00-00-860-009 APU Shutdown by External Power (131-9(A)) AMM 49-11-11-000-004 Removal of the Power Plant (APU) (131-9(A)) AMM 49-11-11-400-004 Installation of the Power Plant (APU) (131-9(A)) AMM 49-90-00-600-008 Oil Change (Drain Method) (131-9(A)) AMM 49-91-41-200-002 Inspection and Replacement of Oil Filters (8069KM)
and (8076KM) (131-9(A))
AMM 49-91-42-200-004 Inspection of the Magnetic- Drain Plug (8077KM)
(131-9(A))
3. Fault Confirmation
__________________
A. Read-out of ECB Trouble-Shooting Data
(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU SHUTDOWN report.
(3) Push the '>' adjacent to LRU DATA:
- the MCDU menu shows
OIL FILTER SHOWS CLOGGED
(4) Start the APU and apply Bleed Air for 20 seconds, minimum (Ref. AMM TASK 49-00-00-860-008).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page A256
201-210, Config-1 Aug 01/05 CES
4. Fault Isolation
_______________
R **ON A/C 001-049, 101-105, 107-107, 151-154, 201-207,
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
CLOGGED OIL FILTER
LUBE PUMP FILTER P9 + GEN SCAV FILTER P5
associated with Fault Code Numbers (FCN) 102
- If the TSM steps below do not clear the fault, do the TSM task (Ref. TASK 49-90-00-810-812).
- do a check for contamination of the MAGNETIC-DRAIN PLUG (Ref. AMM TASK 49-91-42-200-004).
- do a check for contamination of the GEN SCAV OIL FILTER (P5) and LUBE PUMP OIL FILTER (P9):
- remove the GEN SCAV OIL FILTER (P5) and LUBE PUMP OIL FILTER (P9) and do a check of the removed oil filter elements (Ref. AMM TASK 49-91-41-200-002).
(1) If the oil filter element(s) is/are contaminated with: . copper wire particles, . nonmetallic flakes, . phenolic resin.
- remove the APU GENERATOR (8XS) (Ref. AMM TASK 24-23-51-000-001).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 机载辅助动力 2(93)