1. Possible Causes
_______________
- ECB (59KD)
- Load Control Valve (8050KM)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
49-00-81-810-864 "LCV-OPEN"- Signal Fault (131-9(A))
AMM 31-32-00-860-001 Procedure to Get Access to the SYSTEM REPORT/TEST
Menu Page
AMM 49-00-00-710-010 Operational Test of the APU (131-9(A))
AMM 49-61-34-000-003 Removal of the Electronic Control Box (ECB)
(131-9(A))
AMM 49-61-34-400-003 Installation of the Electronic Control Box (ECB)
(131-9(A))
3. Fault Confirmation
__________________
A. Do the operational test of the APU (Ref. AMM TASK 49-00-00-710-010).
(1) Do a check of the APU Bleed Control-Valve indication on the lower ECAM DU (APU Page).
(2) On the MCDU, get access to the APU menu page SYSTEM REPORT/TEST (Ref. AMM TASK 31-32-00-860-001).
4. Fault Isolation
_______________
A. Maintenance Action
(1) If there is a CLASS 2 Fault Message
WRG: APU LOAD VALVE
with the LRU TROUBLE SHOOT DATA menu information:
LOAD VALVE OPEN SIGNAL SHOWS CIRCUIT FAILURE Fault Code Number: 138 and the Bleed Control Valve indication is replaced by amber XX:
- do the trouble shooting of the Load Control Valve (8050KM) (Ref. TASK 49-00-81-810-864).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page B264
201-210, Config-1 Aug 01/05 CES
(2) If there is no CLASS 2 Fault Message and the Bleed Control Valve indication is replaced by amber XX:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and (Ref. AMM TASK 49-61-34-400-003).
B. Do the test given in para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page B265
201-210, Config-1 Aug 01/05 CES
TASK 49-00-81-810-894
APU Bleed Pressure indication replaced by amber XX (131-9(A))
1. Possible Causes
_______________
- ECB (59KD)
- Total Pressure Sensor
- ADIRU 2 is selected OFF or not available
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
49-00-81-810-854 Total-Pressure Transducer (P23) Fault (131-9(A))
AMM 31-32-00-860-001 Procedure to Get Access to the SYSTEM REPORT/TEST
Menu Page
AMM 34-10-00-860-002 ADIRS Start Procedure
AMM 49-00-00-710-010 Operational Test of the APU (131-9(A))
AMM 49-61-34-000-003 Removal of the Electronic Control Box (ECB)
(131-9(A))
AMM 49-61-34-400-003 Installation of the Electronic Control Box (ECB)
(131-9(A))
3. Fault Confirmation
__________________
A. Do the operational test of the APU (Ref. AMM TASK 49-00-00-710-010).
(1) Do a check of the APU Bleed Pressure indication on the lower ECAM DU (APU Page).
(2) On the MCDU, get access to the APU menu page SYSTEM REPORT/TEST (Ref. AMM TASK 31-32-00-860-001).
(3) Select the LAST LEG REPORT page.
4. Fault Isolation
_______________
A. Maintenance Action
(1) If there is a fault message
TOTAL PRESS XDCR (8044KM)
with the LRU TROUBLE SHOOT DATA menu information: TOTAL PRESSURE SENSOR SHOWS OUT OF RANGE HIGH Fault Code Number: 029 or
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page B266
201-210, Config-1 Aug 01/05 CES
TOTAL PRESSURE SENSOR SHOWS OUT OF RANGE LOW
Fault Code Number: 028
or
TOTAL PRESSURE SENSOR SHOWS OUT OF RANGE
Fault Code Number: 026
and the Bleed Pressure indication is replaced by amber XX:
- do the trouble shooting of the Total Pressure Sensor (Ref. TASK 49-00-81-810-854).