 - make sure that the APU rotates freely.


 (a) If the APU rotates freely:
 - replace the APU GENERATOR (8XS) (Ref. AMM TASK 24-23-51-000-001) and (Ref. AMM TASK 24-23-51-400-001).
 1 If the fault continues:
_
 - replace the STARTER MOTOR CLUTCH (Ref. AMM TASK 49-42-52-000-003) and (Ref. AMM TASK 49-42-52-400-003).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page 285
 201-210, Config-1 Aug 01/05 CES 2 If the fault continues:


_
 - replace the STARTER MOTOR (8KA) (Ref. AMM TASK 49-42-51-000-004) and (Ref. AMM TASK 49-42-51-400-004).
 3 If the fault continues:
_
 - replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and (Ref. AMM TASK 49-61-34-400-003).
 (b) If the APU does not rotate freely:
 - replace the APU (4005KM)
 **ON A/C 001-049, 101-105, 151-199, 201-210,
 Post SB 49-1062 For A/C 001-049,101-105,151-154,201-207,
 A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
 NO ACCELERATION
 STARTERMOTOR (8KA)/APU ROTATION

 associated with Fault Code Numbers (FCN) 212
 - do a check of the aircraft BATTERIES (Ref. AMM TASK 24-38-00-210-001).
 (1) If the fault continues:
 - do a check for APU internal damage.
 - do a check for contamination of the MAGNETIC-DRAIN PLUG (8077KM) (Ref. AMM TASK 49-91-42-200-004).
 NOTE : If the MAGNETIC-DRAIN PLUG is not contaminated, continue
____
 without starting the APU.

 - .
 - remove the end cap of the STARTER MOTOR (8KA).

 - use a socket and a ratchet on the shaft of the STARTER MOTOR (8KA) to turn the APU counterclockwise (in the direction of the arrow on the housing).

 - make sure that the APU rotates freely.


 (a) If the APU rotates freely:
 - replace the APU GENERATOR (8XS) (Ref. AMM TASK 24-23-51-000-001) and (Ref. AMM TASK 24-23-51-400-001).
 1 If the fault continues:
_
 - replace the STARTER MOTOR CLUTCH (8033KM) (Ref. AMM TASK 49-42-52-000-003) and (Ref. AMM TASK 49-42-52-400-003).
 2 If the fault continues:
_
 - replace the STARTER MOTOR (8KA) (Ref. AMM TASK 49-42-51-000-004) and (Ref. AMM TASK 49-42-51-400-004).
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page 286
 201-210, Config-1 Aug 01/05 CES 3 If the fault continues:


_
 - replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and (Ref. AMM TASK 49-61-34-400-003).
 (b) If the APU does not rotate freely:
 - replace the APU (4005KM) R **ON A/C 001-049, 101-105, 107-107, 151-199, 201-210,
 B. Do the test given in para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page 287
 201-210, Config-1 Aug 01/05 CES

 TASK 49-00-81-810-831


 APU AUTO SHUTDOWN - NO ACCELERATION, Main Start-Contactor Fault (131-9(A))
 1. Possible Causes
_______________
 - MAIN START CONTACTOR SHOWS OPEN CIRCUIT

 - damage/contamination of the electrical connection STRT MTR (+)

 - aircraft wiring


 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific multimeter
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 49-00-00-860-008 APU Start by External Power (131-9(A)) ASM 49-42/01
 3. Fault Confirmation
__________________
 A. Read-out of ECB Trouble-Shooting Data
 (1) Put the APU MASTER SW to the ON position.
 NOTE : Make sure that the A/C batteries are switched ON|


____

 (2) Get access to the APU SHUTDOWN report.

 (3) Push the '>' adjacent to LRU DATA:

 - the MCDU menu shows
 