(2) Get access to the APU SHUTDOWN report.
(3) Push the '>' adjacent to LRU DATA:
- the MCDU menu shows
BOTH EGT SENSORS FAILED
(4) Start the APU and apply Bleed Air for 20 seconds, minimum (Ref. AMM TASK 49-00-00-860-008).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page 242
201-210, Config-1 Aug 01/05 CES
4. Fault Isolation
_______________
R **ON A/C 001-049, 101-105, 107-107, 151-154, 201-207,
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
SENSOR FAIL
EGT TCPLE RAKE 1 + 2
associated with Fault Code Number (FCN) 35
- replace the EGT 1 and 2 THERMOCOUPLE (Ref. AMM TASK 49-72-15-000-002) and (Ref. AMM TASK 49-72-15-400-003).
(1) If the fault continues:
- do a check and repair of the aircraft wiring from the ECB (59KD) AB/A6,A7 to the EGT1 THERMOCOUPLE terminals alumel/chromel and the ECB (59KD) AB/A8,A9 to the EGT2 THERMOCOUPLE terminals alumel/chromel (Ref. ASM 49-61/01).
(2) If the fault continues:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and (Ref. AMM TASK 49-61-34-400-003).
**ON A/C 001-049, 101-105, 151-199, 201-210,
Post SB 49-1062 For A/C 001-049,101-105,151-154,201-207,
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
SENSOR FAIL
EGT TCPLE RAKES(8057KM1) AND (8057KM2)
associated with Fault Code Number (FCN) 35
- replace the EGT 1 and 2 THERMOCOUPLE (Ref. AMM TASK 49-72-15-000-002) and (Ref. AMM TASK 49-72-15-400-003).
(1) If the fault continues:
- do a check and repair of the aircraft wiring from the ECB (59KD) AB/A6,A7 to the EGT1 THERMOCOUPLE terminals alumel/chromel and the ECB (59KD) AB/A8,A9 to the EGT2 THERMOCOUPLE terminals alumel/chromel (Ref. ASM 49-61/01).
(2) If the fault continues:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and (Ref. AMM TASK 49-61-34-400-003).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page 243
201-210, Config-1 Aug 01/05 CES
R **ON A/C 001-049, 101-105, 107-107, 151-199, 201-210,
B. Do the test given in para. 3.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page 244
201-210, Config-1 Aug 01/05 CES
TASK 49-00-81-810-817
APU AUTO SHUTDOWN - SENSOR FAILURE, ECB internal Fault (131-9(A))
1. Possible Causes
_______________
- ECB INTERNAL FAILURE
- ECB (59KD)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 49-00-00-860-008 APU Start by External Power (131-9(A)) AMM 49-61-34-000-003 Removal of the Electronic Control Box (ECB) (131-9(A)) AMM 49-61-34-400-003 Installation of the Electronic Control Box (ECB) (131-9(A))
3. Fault Confirmation
__________________
A. Read-out of ECB Trouble-Shooting Data
(1) Put the APU MASTER SW to the ON position.
(2) Get access to the APU SHUTDOWN report.
(3) Push the '>' adjacent to LRU DATA:
- the MCDU menu shows
ECB INTERNAL FAILURE
(4) Start the APU and apply Bleed Air for 20 seconds, minimum (Ref. AMM TASK 49-00-00-860-008).
4. Fault Isolation
_______________
A. If an APU auto shutdown occurs during the APU operation and the APU SHUTDOWN report gives the maintenance message:
SENSOR FAIL
ECB (59KD)
associated with the Fault Code Number (FCN) 38
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and (Ref. AMM TASK 49-61-34-400-003).
B. Do the test given in para. 3.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 机载辅助动力 2(50)