 201-210, Config-1 Aug 01/05 CES


 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R  AMM 49-61-34-400-001  Installation of the Electronic Control Box (ECB) 
R  (59KD) (GTCP 36-300) 
R  AMM 49-61-34-400-003  Installation of the Electronic Control Box (ECB) 
R  (131-9(A)) 
R  AMM 71-00-00-710-001  Dry Motoring Check 
R  ASM 49-61/02 
R  ASM 49-62/02 
R  ASM 49-62/04 
R  3. Fault Confirmation__________________ 
R  A. Test 

R (1) Do the ECB self test (Ref. AMM TASK 49-00-00-710-009).
R NOTE : If the self test of the ECB gives a maintenance message, do
____ R the related trouble shooting first before you continue with R this test.
R (2) Get access to the AIDS parameters (ALPHA CALL UP) (Ref. AMM TASK 31-R 36-00-740-008).

R (3) Start and operate the APU (Ref. AMM TASK 49-00-00-860-008).

R (4) On overhead panel 35VU, make sure that the APU GEN p/bsw is released
R (APU GEN off).

R (5) Examine and record the indications of the APU system page on the
R lower ECAM display unit and the AIDS parameters on the MCDU for the
R subsequent conditions.
R Record the trend of the EGT during change of APU running state.

R NOTE : On the MCDU, you can read these AIDS parameters:

____ R - IGV (APU Inlet Guide-Vane position; parameter 7A.1.130.01), R - WB (APU Corrected Bleed-Air Flow; parameter 7A.1.123.01), R - ADW1 (APU Discrete Word - Information regarding APU R operating status; parameter 7A.1.37.01),
R . ADW Alpha code = ADW1 for SAGEM FDIMU


R . ADW Alpha code = APUDSW1 for TELEDYNE FDIMU
R - PD (Main Engine Precooler-Inlet Air-Pressure),


R . Parameter 06F.1.143.01 for Engine 1


R . Parameter 06F.2.143.10 for Engine 1


R . Parameter 06F.1.142.01 for Engine 2


R . Parameter 06F.2.142.10 for Engine 2
R - LCIT (APU Inlet Temperature; parameter 7A.1.123.01),
R - PT (Bleed Air Pressure; parameter 7A.1.166.01).

 

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page B254
 201-210, Config-1 Aug 01/05 CES 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page B255


R  NOTE : On the APU page of the lower ECAM display unit, you can____ 
R  monitor: 
R  - TAT (Total Air Temperature in deg. C) 
R  - GLA (APU Generator Load in %) 
R  - EGT (APU Exhaust Gas Temperature) 
R  (a) APU in RTL (Ready-to-Load) running state: 
R  - on overhead panel 25VU the blue AVAIL legend in the APU START 
R  p/bsw is on; 
R  1_  Record the applicable parameters (Ref. TABLE A).
R  (b) APU in 2 pack ECS running state (PACK 1 and 2): 
R  - on overhead panel 30VU the APU BLEED p/bsw is pushed to ON; 
R  - on overhead panel 30VU the PACK 1 p/bsw is pushed (OFF legend 
R  is off); 
R  - on overhead panel 30VU the PACK 2 p/bsw is pushed (OFF legend 
R  is off); 
R  1_  Record the applicable parameters (Ref. TABLE A).
R  (c) APU in MES (Main Engine Start) running state (ENG1): 
R  1_  Do the dry motoring of the engine 1 (Ref. AMM TASK 71-00-00-
R  710-001); 
R  2_  Record the applicable parameters (Ref. TABLE A).
R  (d) APU in MES (Main Engine Start) running state (ENG2): 
R  1_  Do the dry motoring of the engine 2 (Ref. AMM TASK 71-00-00-
R  710-001); 
R  2_  Record the applicable parameters (Ref. TABLE A).
R  (6) Shutdown the APU (Ref. AMM TASK 49-00-00-860-009). 
R  B. Parameter Values during different APU running states.

 201-210, Config-1 Aug 01/05 CES


R TABLE A R -------+-----------------------------------------------------------+-----------R ALPHA | MODE | R +-----------------+---------------------+-------------------+ R CODE | RTL | 2 ECS | MES | UNIT R -------+-----------------+---------------------+-------------------+-----------R IGV | 22 | 44 - 97 (*) | 91 - 93 | degrees R -------+-----------------+---------------------+-------------------+-----------R WB | N/A | 0.4 - 0.5 | 0.38 - 0.42 | kg/sec R -------+-----------------+---------------------+-------------------+-----------R LCIT | TAT + (1 - 2) | TAT + (1 - 2) | TAT + (1 - 2) | deg.C R -------+-----------------+---------------------+-------------------+-----------R PD1/2 | N/A | > 14/14 | > 20/20 | psig R -------+-----------------+---------------------+-------------------+-----------R PT | N/A | > 1.65 | > 3.5 | psig R -------+-----------------+---------------------+-------------------+-----------R (*) IGV varies as a function of the LCIT and the Zone Controller inputs.
 