- do a check and make sure that the two A321 IDENTIFICATION signals at the ECB (59KD) AB/A12, A13 (Ref. ASM 49-61/01) are the same.
(1) If the two A321 IDENTIFICATION signals are not the same:
- do a check and repair the wiring to the ECB (59KD) AB/A12, A13 (Ref. ASM 49-61/01).
(a) If the fault continues:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-002) and (Ref. AMM TASK 49-61-34-400-002).
(2) If the two A321 IDENTIFICATION are the same:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-002) and (Ref. AMM TASK 49-61-34-400-002).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-106, 108-149, 211-299, 301-399, ∞∞49-61-00∞∞∞∞∞∞∞∞∞∞Page 203
Config-3 Aug 01/05 CES
B. Do the test given in para. 3.
TASK 49-61-00-810-808
Start in Progress Indication Fault (APS 3200)
1. Possible Causes
_______________
- BOARD-ANN LT TEST & INTFC (7LP)
- aircraft wiring
- ECB (59KD)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 33-14-00-710-001 Operational Test of the Annunciator Light Test System in the Cockpit
AMM 33-14-33-000-001 Removal of the Annunciator-Light Test and Interface-Board (1LP, 2LP, 3LP, 4LP, 5LP, 6LP, 7LP, 8LP, 9LP, 10LP, 11LP, 12LP, 18LP, 19LP, 20LP)
AMM 33-14-33-400-001 Installation of the Annunciator-Light Test and Interface-Board (1LP, 2LP, 3LP, 4LP, 5LP, 6LP, 7LP, 8LP, 9LP, 10LP, 11LP, 12LP, 18LP, 19LP, 20LP)
AMM 49-00-00-710-008 Operational Test of the APU (APS 3200) AMM 49-61-34-000-002 Removal of the Electronic Control Box (ECB) (59KD) (APS 3200) AMM 49-61-34-400-002 Installation of the Electronic Control Box (ECB) (59KD) (APS 3200) ASM 49-42/01
3. Fault Confirmation
__________________
A. Do the operational test of the APU (Ref. AMM TASK 49-00-00-710-008).
4. Fault Isolation
_______________
A. If the APU Class 3 Faults Page gives the maintenance message:
WRG: ECB PIN AB-H9
Fault Code Number: 019 or 087
- do the Operational Test of the Annunciator Light Test System in the Cockpit (Ref. AMM TASK 33-14-00-710-001).
(1) If the fault continues:
- replace BOARD-ANN LT TEST & INTFC (7LP) (Ref. AMM TASK 33-14-33-000-001) and (Ref. AMM TASK 33-14-33-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 106-106, 108-149, 211-299, 301-399, ∞∞49-61-00∞∞∞∞∞∞∞∞∞∞Page 205
Config-3 Aug 01/05 CES (2) If the Annunciator Light Test is OK:
- check and repair the aircraft wiring between ECB (59KD) AB/H9 and RELAY BOARD (7LP) A/15 (in case of FCN 019 for a short ciruit) and between A45 and GND (Ref. ASM 49-42/01).
(a) If the fault continues:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-002) and (Ref. AMM TASK 49-61-34-400-002).
B. Do the test given in para. 3.
TASK 49-61-00-810-809
APU Available Indication Fault (APS 3200)
1. Possible Causes
_______________
- BOARD-ANN LT TEST & INTFC (7LP)
- aircraft wiring
- ECB (59KD)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 33-14-00-710-001 Operational Test of the Annunciator Light Test System in the Cockpit
AMM 33-14-33-000-001 Removal of the Annunciator-Light Test and Interface-Board (1LP, 2LP, 3LP, 4LP, 5LP, 6LP, 7LP, 8LP, 9LP, 10LP, 11LP, 12LP, 18LP, 19LP, 20LP)
AMM 33-14-33-400-001 Installation of the Annunciator-Light Test and Interface-Board (1LP, 2LP, 3LP, 4LP, 5LP, 6LP, 7LP, 8LP, 9LP, 10LP, 11LP, 12LP, 18LP, 19LP, 20LP)
AMM 49-00-00-710-008 Operational Test of the APU (APS 3200) AMM 49-61-34-000-002 Removal of the Electronic Control Box (ECB) (59KD) (APS 3200) AMM 49-61-34-400-002 Installation of the Electronic Control Box (ECB) (59KD) (APS 3200) ASM 49-42/01
3. Fault Confirmation
__________________
中国航空网 www.aero.cn
航空翻译 www.aviation.cn