• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-29 09:20来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者


 4. Fault Isolation
_______________
R **ON A/C 001-049, 101-105, 107-107, 151-154, 201-207,

R A. If the APU GND SCANNING menu gives the maintenance message:
R
R INLET PRESS XDCR P22
R
R associated with Fault Code Number (FCN) 21, 22, 23 or 24
R
R - do a check for damage/contamination of electrical connector P22 of the
R INLET PRESSURE TRANSDUCER (P22)

R (1) If the electrical connector P22 is damaged/contaminated:
R - do a repair/cleaning.

R (2) If the electrical connector is OK:
R - replace the INLET PRESSURE TRANSDUCER (P22) (Ref. AMM TASK 49-51-R 21-000-001) and (Ref. AMM TASK 49-51-21-400-001).

R (a) If the fault continues:
R - do a check and repair of the aircraft wiring from the ECB
R (59KD) AB/C8,C9 to the INLET PRESSURE TRANSDUCER (P22) P22/4,5
R (Ref. ASM 49-61/02).

R  1_  If the fault continues:
R  - replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and 
R  (Ref. AMM TASK 49-61-34-400-003).

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page A296
 201-210, Config-1 Aug 01/05 CES


R  B. If the TEST menu or the APU GND SCANNING menu gives the maintenance 
R  message: 

R  TOTAL PRESS XDCR P24 

R  associated with Fault Code Number (FCN) 27 

R  - do a check for damage/contamination of electrical connector P23 of the 
R  TOTAL PRESSURE TRANSDUCER (P23) 
R  - do a check for damage/contamination of electrical connector P24 of the 
R  DIFFERENTIAL PRESSURE TRANSDUCER (P24) 
R  (1) If the electriacl connector P23/P24 are damaged/contaminated: 
R  - do a repair/cleaning. 
R  (2) If the electrical connectors are OK: 
R  - replace the TOTAL PRESSURE TRANSDUCER (P23) (Ref. AMM TASK 49-51-
R  17-000-002) and (Ref. AMM TASK 49-51-17-400-002). 
R  (a) If the fault continues: 
R  - replace the DIFFERENTIAL PRESSURE TRANSDUCER (P24) (Ref. AMM 
R  TASK 49-51-16-000-002) and (Ref. AMM TASK 49-51-16-400-002). 
R  1 If the fault continues:_ 
R  - replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and 
R  (Ref. AMM TASK 49-61-34-400-003).
 **ON A/C 001-049, 101-105, 151-199, 201-210,
 Post SB 49-1062 For A/C 001-049,101-105,151-154,201-207, 
R  A. If the APU GND SCANNING menu gives the maintenance message: 

R  INLET PRESS XDCR (8048KM) 

R  associated with Fault Code Number (FCN) 21, 22, 23 or 24 

R  - do a check for damage/contamination of electrical connector P22 of the 
R  INLET PRESSURE TRANSDUCER (8048KM) 
R  (1) If the electrical connector P22 is damaged/contaminated: 
R  - do a repair/cleaning. 
R  (2) If the electrical connector is OK: 
R  - replace the INLET PRESSURE TRANSDUCER (8048KM) (Ref. AMM TASK 49-
R  51-21-000-001) and (Ref. AMM TASK 49-51-21-400-001). 
R  (a) If the fault continues: 
R  - do a check and repair of the aircraft wiring from the ECB 
R  (59KD) AB/C8,C9 to the INLET PRESSURE TRANSDUCER (8048KM) 
R  P22/4,5 (Ref. ASM 49-61/02).

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-00-81∞∞∞∞∞∞∞∞∞∞Page A297
 201-210, Config-1 Aug 01/05 CES


R  1 If the fault continues:_ 
R  - replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and 
R  (Ref. AMM TASK 49-61-34-400-003). 
R  B. If the TEST menu or the APU GND SCANNING menu gives the maintenance 
R  message: 

R  TOTAL PRESS XDCR (8044KM) 

R  associated with Fault Code Number (FCN) 27 

R  - do a check for damage/contamination of electrical connector P23 of the 
R  TOTAL PRESSURE TRANSDUCER (8044KM). 
R  - do a check for damage/contamination of electrical connector P24 of the 
R  DIFFERENTIAL PRESSURE TRANSDUCER (8043KM) 
R  (1) If the electriacl connectors P23/P24 are damaged/contaminated: 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 机载辅助动力 2(109)