• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-29 09:20来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 201-210, Config-2 Aug 01/05 CES -------------------------------------------------------------------------------


FCN | Fault Description | CFDS Message | Class
 ----+----------------------------------------+-------------------------+-------
----+----------------------------------------+-------------------------+-------
008 | Speed Sensor 2 shows open circuit | SPEED SENSOR P26 | 3
 ----+----------------------------------------+-------------------------+-------
009 | Speed Sensor 1 shows amplitude Failure | SPEED SENSOR P26 | 3
 ----+----------------------------------------+-------------------------+-------
010 | Speed Sensor 2 shows amplitude Failure | SPEED SENSOR P26 | 3
 ----+----------------------------------------+-------------------------+-------
011 | ECB internal Failure | ECB (59KD) | 3
 ----+----------------------------------------+-------------------------+-------
012 | ECB internal Failure | ECB (59KD) | 3
 ----+----------------------------------------+-------------------------+-------
013 | ECB internal Failure | ECB (59KD) | 3
 ----+----------------------------------------+-------------------------+-------
014 | ECB internal Failure | ECB (59KD) | 3
 ----+----------------------------------------+-------------------------+-------
015 | ECB internal Failure | ECB (59KD) | 1
 ----+----------------------------------------+-------------------------+-------
016 | Delta Press. Sensor shows out of range | DIFFERENTIAL PRESS XDCR | 1
 | drift | P24 | ----+----------------------------------------+-------------------------+-------017 | Delta Press. Sensor shows out of range | DIFFERENTIAL PRESS XDCR | 1
 | drift | P24 | ----+----------------------------------------+-------------------------+-------018 | Delta Press. Sensor shows out of range | DIFFERENTIAL PRESS XDCR | 1
 | low | P24 | ----+----------------------------------------+-------------------------+-------019 | Delta Press. Sensor shows out of range | DIFFERENTIAL PRESS XDCR | 1
 | high | P24 | ----+----------------------------------------+-------------------------+-------020 | ECB internal Failure | ECB (59KD) | 2 ----+----------------------------------------+-------------------------+-------021 | Inlet Press. Sensor shows out of range | INLET PRESS XDCR P22 | 2 ----+----------------------------------------+-------------------------+-------022 | Inlet Press. Sensor shows < 8 psia | INLET PRESS XDCR P22 | 2
 | on ground | | ----+----------------------------------------+-------------------------+-------023 | Inlet Press. Sensor shows out of range | INLET PRESS XDCR P22 | 2
 | low | | ----+----------------------------------------+-------------------------+-------024 | Inlet Press. Sensor shows out of range | INLET PRESS XDCR P22 | 2
 | high | | ----+----------------------------------------+-------------------------+-------025 | ECB internal Failure | ECB (59KD) | 1 ----+----------------------------------------+-------------------------+-------026 | Total Pressure Sensr. shows out of | TOTAL PRESS XDCR P23 | 1
 | range | | ----+----------------------------------------+-------------------------+-------027 | Total Pressure and Inlet Pressure | TOTAL PRESS XDCR P23 | 1
 | disagree | |
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-154, ∞∞49-00-00∞∞∞∞∞∞∞∞∞∞Page 311
 201-207, Config-2 Aug 01/05 CES -------------------------------------------------------------------------------


FCN | Fault Description | CFDS Message | Class
 ----+----------------------------------------+-------------------------+-------
----+----------------------------------------+-------------------------+-------
028 | Total Pressure Sensr. shows out of | TOTAL PRESS XDCR P23 | 1
 | range low | | ----+----------------------------------------+-------------------------+-------029 | Total Pressure Sensr. shows out of | TOTAL PRESS XDCR P23 | 1
 | range high | | ----+----------------------------------------+-------------------------+-------030 | Press XDCR wiring shows open circuit | CHECK PRESS XDCR WIRING | 1 ----+----------------------------------------+-------------------------+-------031 | Press XDCR wiring open or ECB internal | CHECK PRESS XDCR WIRING | 1
 | failure | / ECB (59KD) | ----+----------------------------------------+-------------------------+-------032 | ECB internal Failure | ECB (59KD) | 1 ----+----------------------------------------+-------------------------+-------033 | N O T U S E D | | ----+----------------------------------------+-------------------------+-------034 | N O T U S E D | | ----+----------------------------------------+-------------------------+-------035 | Both EGT Sensors failed | EGT TCPLE RAKES 1 + 2 | 1 ----+----------------------------------------+-------------------------+-------036 | EGT1 Sensor Failure and ECB Internal | EGT TCPLE RAKE 1 | 1
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 机载辅助动力 2(20)