- do a repair/cleaning.
(2) If the electrical connector is OK:
- use a multimeter to do a resistance check across pin A and pin B of the INLET TEMPERATURE SENSOR (P6).
(a) If the resistance is < 72 Ohms:
- replace the INLET TEMPERATURE SENSOR (8010KM) (Ref. AMM TASK 49-23-14-000-001) and (Ref. AMM TASK 49-23-14-400-001).
(b) If the resistance is between 72 Ohms and 200 Ohms:
- do a check and repair of the aircraft wiring from the ECB (59KD) AB/H4,H2 to the INLET TEMPERATURE SENSOR (8010KM) P6/A,B (Ref. ASM 49-61/02).
1 If the fault continues:
_
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and (Ref. AMM TASK 49-61-34-400-003).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-20-00∞∞∞∞∞∞∞∞∞∞Page 203
201-210, Config-2 Aug 01/05 CES
B. If the APU GND SCANNING menu gives the maintenance message:
INLET TEMP SENSOR (8010KM)
associated with Fault Code Number (FCN) 58
- do a check for damage/contamination of electrical connector P6 of the INLET TEMPERATURE SENSOR (8010KM)
(1) If the electrical connector P6 is damaged/contaminated:
- do a repair/cleaning.
(2) If the electrical connector is OK:
- use a multimeter to do a resistance check across pin A and pin B of the INLET TEMPERATURE SENSOR (P6).
(a) If the resistance is > 200 Ohms:
- replace the INLET TEMPERATURE SENSOR (8010KM) (Ref. AMM TASK 49-23-14-000-001) and (Ref. AMM TASK 49-23-14-400-001).
(b) If the resistance is between 72 Ohms and 200 Ohms:
- do a check and repair of the aircraft wiring from the ECB (59KD) AB/H4,H3 to the INLET TEMPERATURE SENSOR (8010KM) P6/A,B (Ref. ASM 49-61/02).
1 If the fault continues:
_
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-003) and (Ref. AMM TASK 49-61-34-400-003).
R **ON A/C 001-049, 101-105, 107-107, 151-199, 201-210,
C. Do a check of the APU GND SCANNING menu.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 101-105, 107-107, 151-199, ∞∞49-20-00∞∞∞∞∞∞∞∞∞∞Page 204
201-210, Config-2 Aug 01/05 CES
IGNITION AND STARTING ((GTCP 36-300)) - FAULT ISOLATION PROCEDURES
__________________________________________________________________
R **ON A/C 001-003, 051-099, 401-499,
TASK 49-40-00-810-801
Main Start-Contactor Fault (GTCP 36-300)
1. Possible Causes
_______________
- CONTACTOR-MAIN START (5KA)
- ECB (59KD)
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION
-------------------------------------------------------------------------------
AMM 49-00-00-710-004 Operational Test of the APU (4005KM) (GTCP 36-300)
AMM 49-42-55-000-001 Removal of the Start Contactors (5KA,10KA)
AMM 49-42-55-400-001 Installation of the Start Contactors (5KA,10KA)
AMM 49-61-34-000-001 Removal of the Electronic Control Box (ECB) (59KD)
(GTCP 36-300) AMM 49-61-34-400-001 Installation of the Electronic Control Box (ECB) (59KD) (GTCP 36-300)
3. Fault Confirmation
__________________
A. Do the operational test of the APU (Ref. AMM TASK 49-00-00-710-004).
4. Fault Isolation
_______________
**ON A/C 001-003, 051-062,
A. If the test gives the maintenance message:
CONTACTOR 5KA:
- replace the CONTACTOR-MAIN START (5KA) (Ref. AMM TASK 49-42-55-000-001) and (Ref. AMM TASK 49-42-55-400-001).
(1) If the fault continues after the first flight on the subsequent day:
- replace the ECB (59KD) (Ref. AMM TASK 49-61-34-000-001) and (Ref. AMM TASK 49-61-34-400-001).
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-003, 051-099, 401-499, ∞∞49-40-00∞∞∞∞∞∞∞∞∞∞Page 201
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 机载辅助动力 2(147)