Text for CFDS Indication | ATA | BITE Detection (Failed LRUs)
============================+==========+======================================= OIL SUMP TEMP SENSOR | 49-91-51 | Oil sump temp sensor shows (8084KM) | | out of range low/high
----------------------------+----------+---------------------------------------OIL LEVEL SWITCH (8087KM) | 49-93-00 | Oil quantity switches disagree ----------------------------+----------+---------------------------------------LOW OIL LEVEL | 49-93-00 | Oil level shows low ----------------------------+----------+---------------------------------------OIL TEMP SWITCH (8090KM) | 49-94-13 | Oil Temp Switch shows open circuit ----------------------------+----------+---------------------------------------LOW OIL PRESS SW (8091KM) | 49-94-14 | LOP Switch shows electrical gnd ----------------------------+----------+---------------------------------------APU OIL HEATER (8093KM) | 49-96-51 | Oil Heater Failure ----------------------------+----------+---------------------------------------
(b) CLASS 3 Faults
Table 3
-------------------------------------------------------------------------------Text for CFDS Indication | ATA | BITE Detection (Failed LRUs) ============================+==========+======================================= NO DEMAND DATA FROM ECS | 21-63-34 | ECS Zone Controller | | ECS Demand failure ----------------------------+----------+---------------------------------------NO PACK DATA FROM ECS | 21-63-34 | ECS Zone Controller | | ECS Data failure
----------------------------+----------+---------------------------------------GENERATOR OIL TEMP | 24-23-51 | Generator oil temp sensor shows out SENSOR (8XS) | | of range high/low
----------------------------+----------+---------------------------------------
NO DATA FROM CFDIU | 31-32-34 | AC ID failure, GMT failure, | | Date failure, BITE command failure, | | Flight phase failure, AC config fail
----------------------------+----------+---------------------------------------AIR INTAKE FLAP ACTUATOR | 49-16-51 | Inlet Flap shows flap open and flap (4015KM) | | closed
| | Inlet Flap shows Flap open switch open | | Inlet Flap shows Flap closed switch | | open
----------------------------+----------+---------------------------------------LOAD COMPRESSOR INLET | 49-23-15 | LCIT sensor shows out of range low TEMP SENSOR (8011KM) | |