R TASK 24-20-00-810-919
R Overload on the Electrical Network of the Generator 2
R 1. Possible Causes_______________
R - MAIN-GALLEY A/PWR/SPLY (3MC)
R - GALLEY D (2MC)
R - wiring
R 2. Job Set-up Information______________________
R A. Referenced Information
R -------------------------------------------------------------------------------
R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------
R AMM 24-41-00-861-002
R
R AMM 24-41-00-862-002
R
R AMM 71-00-00-710-003
R AMM 71-00-00-710-028
R AMM 71-00-00-710-043
R ASM 24-51/03
R 3. Fault Confirmation
__________________ R A. Job Set-up
Energize the Aircraft Electrical Circuits from the External Power De-energize the Aircraft Electrical Circuits Supplied from the External Power Engine Automatic Start Engine Shutdown Normal Engine Automatic Start Procedure
R (1) Aircraft Maintenance Configuration
R (a) Energize the aircraft electrical circuits from the external power
R (Ref. AMM TASK 24-41-00-861-002).
R (2) On the ELEC panel 35VU, make sure that the ELEC/GEN 2 pushbutton
R switch (3XU2) is pushed.
R (3) On the ELEC panel 35VU, make sure that the ELEC/GALLEY pushbutton
R switch (2XA) is pushed (the OFF legend is off).
R B. Test
R (1) Start the engine 2 (Ref. AMM TASK 71-00-00-710-003).
R (2) On the upper ECAM DU, the warning GEN 2 OVERLOAD is shown.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 401-499, ∞∞24-20-00∞∞∞∞∞∞∞∞∞∞Page B296
Aug 01/05 CESR 4. Fault Isolation
_______________
R A. Table of the circuit breakers used in this procedure:
R -------------------------------------------------------------------------------R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------R 123VU TR2/214XP/SPLY 2PU2 AB04
R 123VU Y HYD/ELEC/ELEC PUMP/NORM 3801GX AB03
R 123VU BUS 2/204XP/SPLY 3XN2 AB02
R 123VU BUS 2/231XP-A/SPLY 5XN2 AB01
R 123VU AC ESS/BUS ON/BUS 2 2XC AC01
R 123VU BUS 2/212XP/SPLY 10XN AD03
R 123VU BUS 2/202XP/SPLY 1XN2 AD02
R 123VU AVNCS VENT/EXTC/FAN 2HQ AE02
R 123VU ANTI ICE/R/WHSLD 1DG2 AF03
R 123VU BUS 2/210XP/SPLY 7XN2 AF02
R B. If the test confirms the fault:
R - in the AC power center panel 123VU, do a check of the circuit breakers
R 3MC and 2MC.
R (1) If the circuit breakers 3MC and/or 2MC are open:
R - replace the MAIN-GALLEY A/PWR/SPLY (3MC) and/or the GALLEY D (2MC).
R (2) If the circuit breakers 3MC and 2MC are closed:
R - on the AC power center panel 123VU, do a check of the status of the
R circuit breakers 5XN2, 3XN2, 7XN2, 1DG2, 2XC, 2HQ, 1XN2, 2PU2, 10XN
R and 3801GX.
R (a) If one or more circuit breaker(s) is(are) open:
R - do a check of the loads downstream of the open circuit