R **ON A/C 061-099, 103-149, 151-199, 202-299, 301-399, 401-499,
B. Test
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the ECAM control panel: - push the ELEC key to get the ELEC page. On the upper ECAM DU:- the GEN 1 OVERLOAD message comes intoview.
2. On the ELEC panel 35VU: - release the GALY & CAB pushbutton switch (2XA). If on the upper ECAM DU:- the GEN 1 OVERLOAD message goes outof view, stop the trouble shooting. If on the upper ECAM DU: - the GEN 1 OVERLOAD message stays in view, continue the trouble shooting (refer to the fault isolation which follows).
**ON A/C ALL
4. Fault Isolation
_______________
A. Table of the circuit breakers used in this procedure:
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
**ON A/C 001-049, 051-060, 101-102, 201-201,
122VU ELEC/GALLEY/CTL 1XA S26
122VU ELEC/GALLEY/FAULT/LT CTL 8XA S25
**ON A/C ALL
122VU ELEC/GCU/1 2XU1 T26
R **ON A/C 061-099, 103-149, 151-199, 202-299, 301-399, 401-499,
122VU ELEC/GALY & CAB/CTL 1XA S26
122VU ELEC/GALY & CAB/FAULT/LT CTL 8XA S25
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
B. If the test confirms the fault:
- open the circuit breakers 8XA and 1XA
- replace the P/BSW-ELEC/GALLEY (2XA) (Ref. AMM TASK 33-10-00-000-002) and (Ref. AMM TASK 33-10-00-400-002)
- close the circuit breakers 8XA and 1XA.
(1) If the fault continues:
- remove the GCU1 (1XU1) (Ref. AMM TASK 24-22-34-000-001)
- close the circuit breaker 2XU1.
(a) If the fault does not continue:
- install a new GCU-1 (1XU1) (Ref. AMM TASK 24-22-34-400-001).
(b) If the fault continues:
- open the circuit breakers 8XA and 1XA
- disconnect the connector of the diode module 1162VD (Ref. IPC 25710104)
- close the circuit breakers 8XA and 1XA.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-22-00∞∞∞∞∞∞∞∞∞∞Page 245
Aug 01/05 CES 1 If the fault does not continue:
_ - open the circuit breakers 8XA and 1XA
- replace the diode module 1162VD (Ref. IPC 25710104)
- install the GCU1 (1XU1) (Ref. AMM TASK 24-22-34-400-001)
- close the circuit breakers 8XA and 1XA.
2 If the fault continues:
_
- replace the EGIU-1 (22XU1) (Ref. AMM TASK 24-22-33-000-001) and (Ref. AMM TASK 24-22-33-400-002).
a If the fault does not continue:
_ - open the circuit breakers 8XA and 1XA
- connect the connector of the diode module 1162VD (Ref. IPC 25710104)
- install the GCU1 (1XU1) (Ref. AMM TASK 24-22-34-400-001)
- close the circuit breakers 8XA and 1XA.
b If the fault continues:
_ - open the circuit breakers 8XA and 1XA
- do a check and repair the wiring between: . the pin A/14 of the diode module 1162VD and the pin AA/13B of the GCU1 (1XU1) . the pin A/14 of the diode module 1162VD and the pin AA/6A of the EGIU1 (22XU1)
- connect the connector of the diode module 1162VD (Ref. IPC 25710104)
- install the GCU1 (1XU1) (Ref. AMM TASK 24-22-34-400-001)
- close the circuit breakers 8XA and 1XA.
R **ON A/C 401-499,
R B. If the test confirms the fault:
R - open the circuit breakers 8XA and 1XA
R - replace the P/BSW-ELEC/GALLEY (2XA)
R - close the circuit breakers 8XA and 1XA.
R (1) If the fault continues:
R - remove the GCU 1 (1XU1) (Ref. AMM TASK 24-22-34-000-001)
R - close the circuit breaker 2XU1.
R (a) If the fault does not continue:
R - install a new GCU-1 (1XU1) (Ref. AMM TASK 24-22-34-400-001).
R (b) If the fault continues:
R - open the circuit breakers 8XA and 1XA
R - disconnect the connector of the diode module 1162VD (Ref. IPC
R 25710104)
R - close the circuit breakers 8XA and 1XA.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-22-00∞∞∞∞∞∞∞∞∞∞Page 246 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 电源 2(146)