 voltage indication shows amber, do the trouble shooting given in Para. 4.B.
 On the lower ECAM DU:
 - if amber crosses replace the load indication of the GEN 2 or if the
 load indication shows amber, do the trouble shooting given in Para. 4.C.
 On the lower ECAM DU:
 - if amber crosses replace voltage, frequency and load indications, do the trouble shooting given in Para. 4.D. 
R  **ON A/C 401-499, 
R  B. Test 

R  -------------------------------------------------------------------------------
R  ACTION  RESULT 
R  -------------------------------------------------------------------------------

R  1. On the ECAM control panel:  On the lower ECAM DU: 
R  - push the ELEC key to get the  - if amber crosses replace the voltage 
R  ELEC page.  indication or the frequency 
R  indication of the GEN 2 or if the 
R  voltage indication or the frequency 
R  indication shows amber, do the 
R  trouble shooting given in Para. 4.B. 
R  On the lower ECAM DU: 
R  - if amber crosses replace the voltage 
R  indication or the frequency 
R  indication of the GEN 2, or if the 
R  load indication is shown in amber or 
R  if the load indication is replaced by

 

 -------------------------------------------------------------------------------
ACTION ----------------------------------- RESULT--------------------------------------------
R  amber crosses, do the trouble 
R  shooting given in Para. 4.C. 
R  On the lower ECAM DU: 
R  - if amber crosses replace voltage, 
R  frequency and load indications, do 
R  the trouble shooting given in Para. 
R  4.D. 
R  **ON A/C ALL
 4. Fault Isolation_______________ 
R  **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399,
 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 ------PANEL  -----------------------------------DESIGNATION  --------------------------------------IDENT. LOCATION

 -------------------------------------------------------------------------------123VU GEN2/EGIU2/115VAC 23XU2 AF01
 **ON A/C 001-049, 051-062, 101-105, 151-152, 201-205,
 B. If the test confirms the fault:
 - replace the EGIU-2 (22XU2) (Ref. AMM TASK 24-22-33-000-001) and (Ref. AMM TASK 24-22-33-400-002).
 (1) If the fault continues:
 - do a check of the position of the circuit breaker (23XU2).
 (a) If the circuit breaker (23XU2) is open:
 - close it.
 1 If the circuit breaker trips:
_
 - do a check for a short to ground between the pin 2 of the circuit breaker GEN2/EGIU2/115VAC (23XU2) and the pin AA/15D of the EGIU2 (22XU2) (Ref. ASM 24-22/01),

 - if there is a short to ground: . repair the wiring,

 - if there is no short to ground: . replace the C/B-GEN2/EGIU2/115VAC (23XU2).


 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : ALL ∞∞24-22-00∞∞∞∞∞∞∞∞∞∞Page 217
 Aug 01/05 CES (b) If the circuit breaker (23XU2) is closed:


 - do a check and repair the wiring between the pin 2 of the circuit breaker GEN2/EGIU2/115VAC (23XU2) and the pin AA/15D of the EGIU2 (22XU2) (Ref. ASM 24-22/01).
 1 If the fault continues:
_
 - do a check and repair the wiring between the pin 1 of the circuit breaker GEN2/EGIU2/115VAC (23XU2) and the pin A/D of the GLC2 (9XU2) (Ref. ASM 24-22/01).
 **ON A/C 063-099, 106-149, 153-199, 206-299, 301-399,
 B. If the test confirms the fault:
 - replace the EGIU-2 (22XU2) (Ref. AMM TASK 24-22-33-000-001) and (Ref. AMM TASK 24-22-33-400-002).
 (1) If the fault continues:
 - do a check of the position of the circuit breaker (23XU2).
 (a) If the circuit breaker (23XU2) is open:
 - close it.
 1 If the circuit breaker trips:
_
 - do a check for a short to ground between the pin 2 of the circuit breaker GEN2/EGIU2/115VAC (23XU2) and the pin 1 of the module 30XN2 (22XU2) (Ref. ASM 24-22/01),

 - if there is a short to ground: . repair the wiring,

 - if there is no short to ground: . replace the C/B-GEN2/EGIU2/115VAC (23XU2).


 (b) If the circuit breaker (23XU2) is closed:
 - do a check and repair the wiring between the pin 2 of the circuit breaker GEN2/EGIU2/115VAC (23XU2) and the pin AA/15D of the EGIU2 (22XU2) (Ref. ASM 24-22/01).
 