「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 401-499, ∞∞24-20-00∞∞∞∞∞∞∞∞∞∞Page B273
Aug 01/05 CES
R TASK 24-20-00-810-911
R Failure of the IDG 2 PMG Stator or its Wiring to the GCU 2 R 1. Possible Causes
_______________
R - IDG (4000XU) R - GCU-2 (1XU2) R - wiring
R 2. Job Set-up Information
______________________
R A. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R AMM 24-21-51-000-040 R R AMM 24-21-51-400-040 R R AMM 24-22-34-000-001 R AMM 24-22-34-400-001 R AMM 24-41-00-740-002 R AMM 24-41-00-861-002 R R AMM 24-41-00-862-002 R R AMM 31-60-00-860-001 R AMM 31-60-00-860-002 R AMM 71-00-00-710-003 R AMM 71-00-00-710-028 R ASM 24-22/01
R 3. Fault Confirmation
__________________
R A. Test
R Not applicable.
Removal of the Integrated Drive Generator -IDG 1(2),(4000XU) Installation of the Integrated Drive Generator -IDG 1(2),(4000XU) Removal of the GCU-1(2) (1XU1, 1XU2) Installation of the GCU-1(2) (1XU1, 1XU2) Operational Check of GAPCU via CFDS Energize the Aircraft Electrical Circuits from the External Power De-energize the Aircraft Electrical Circuits Supplied from the External Power EIS Start Procedure EIS Stop Procedure Engine Automatic Start Engine Shutdown
R NOTE : As the GEN 2 was set to OFF because of a true failure, the fault
____ R confirmation is not necessary.
R 4. Fault Isolation
_______________
R CAUTION : BEFORE YOU START THE CHECK OF IDG WIRING THAT INCLUDES CONNECTORS,
_______ R EXAMINE EACH CONNECTOR TO MAKE SURE THAT THERE IS NO OIL IN IT. R IF YOU FIND OIL, CLEAN THE CONNECTOR AND CONNECT IT AGAIN. R IF THE FAILURE CONTINUES, DO THE TROUBLE SHOOTING PROCEDURE AS R GIVEN BELOW.
「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 401-499, ∞∞24-20-00∞∞∞∞∞∞∞∞∞∞Page B274
Aug 01/05 CES
R A. If the fault symptom is identified by the CFDS message IDG2 (E2-4000XU)
R PMG/ GCU2 (1XU2) and the upper ECAM-DU warning GEN 2 FAULT:
R (1) If the CFDS message comes into view with the fault codes 104 (UV TRIP
R / SOPMG keyword), 187 (PMG OPEN / SHORT keyword) or 260 (UF TRIP /
R SOPMG keyword):
R - do a check of the resistance of the IDG 2 PMG stator (Ref. ASM 24-R 22/01) between:
R . pins B/12 and B/13 (1 ohm plus or minus 0.05 ohm)
R . pins B/12 and B/14 (1 ohm plus or minus 0.05 ohm)
R . pins B/13 and B/14 (1 ohm plus or minus 0.05 ohm).
R (a) If the resistance values are out of the specified limits:
R - replace the engine 2 IDG (4000XU) (Ref. AMM TASK 24-21-51-000-R 040) and (Ref. AMM TASK 24-21-51-400-040).
R (b) If the resistance values are in the specified limits:
R - do a check of the wiring of the IDG 2 PMG stator (Ref. ASM 24-R 22/01) for a short circuit, an open circuit, a short to ground
R or a short to shield between:
R . pin B/12 of the IDG 2 and pin C/10 of the GCU 2
R . pin B/13 of the IDG 2 and pin C/11 of the GCU 2
R . pin B/14 of the IDG 2 and pin C/9 of the GCU 2
R . pins C/10, C/11, C/9 and pin C/7 of the GCU 2 (short to R shield of the PMG wiring). 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320 Trouble Shooting Manual 排故手册 电源 2(54)