R NOTE : As the GEN 1 was set to OFF because of a true failure, the fault
____ R confirmation is not necessary.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 401-499, ∞∞24-20-00∞∞∞∞∞∞∞∞∞∞Page B249
 Aug 01/05 CESR 4. Fault Isolation


_______________
R A. If the fault symptom is identified by the CFDS message IDG1 (E1-4000XU) R LOW OIL PRESSURE and the upper ECAM-DU warning IDG 1 OIL LO PR:
R NOTE : This CFDS message can come into view with other CFDS messages. Do
____ R the trouble shooting for all CFDS messages related to the IDG 1.
R - do a check of the Differential Pressure Indicator (DPI) of the IDG 1
R (Ref. AMM TASK 24-21-00-210-046).

R (1) If the DPI is extended:
R - replace the engine 1 IDG (4000XU) (Ref. AMM TASK 24-21-51-000-040)
R and (Ref. AMM TASK 24-21-51-400-040).

R (2) If the DPI is not extended:
R - do a check of the IDG 1 oil level (Ref. AMM TASK 24-21-00-210-046).

R (a) If the oil level is not correct:
R - do a visual inspection of the IDG 1, the external oil-circuit
R tubing and the fuel/oil heat exchanger for oil leaks (Ref. AMM
R TASK 24-21-00-210-047).

R  1_  If you find leaks:
R  - repair or replace the components as necessary to remove the 
R  oil leaks. 

R 2_ If you find no leaks:
R - add oil (Ref. AMM TASK 12-13-24-612-041)
R - connect the IDG 1 (if disconnected)
R - do a dynamic disconnect test of the IDG 1 (Ref. AMM TASK 24-R 21-00-720-041).

R a_ If the oil pressure is correct:
R - stop the trouble shooting.

R (3) If the fault continues:
R - do the BITE test of the GAPCU (Ref. AMM TASK 24-41-00-740-002).

R (a) If the BITE test gives the message TEST FAILED:
R - push the line key adjacent to the TEST FAILED message.

R 1_ If the maintenance message GCU1 (1XU1) comes into view:
R - replace the GCU-1 (1XU1) (Ref. AMM TASK 24-22-34-000-001)
R and (Ref. AMM TASK 24-22-34-400-001).

R (b) If the BITE test gives the message TEST PASSED:
R - do a check of the low-oil pressure wiring for a short to ground
R between pin C/A of the IDG 1 and pin A/4A of the GCU 1 (Ref.
R ASM 24-21/01).

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 401-499, ∞∞24-20-00∞∞∞∞∞∞∞∞∞∞Page B250
 Aug 01/05 CES


R 1_ If the wiring is not correct:
R - repair or replace as necessary.

R 2_ If the wiring is correct:
R - replace the engine 1 IDG (4000XU) (Ref. AMM TASK 24-21-51-R 000-040) and (Ref. AMM TASK 24-21-51-400-040).

R a_ If the fault continues:
R - replace the GCU-1 (1XU1) (Ref. AMM TASK 24-22-34-000-001)
R and (Ref. AMM TASK 24-22-34-400-001).

R B. Do this operational test to make sure that the system operates correctly.

R (1) Aircraft Maintenance Configuration

R (a) Energize the aircraft electrical circuits
R (Ref. AMM TASK 24-41-00-861-002).

R (b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
R (Ref. AMM TASK 31-60-00-860-001).

R (2) On the ELEC panel 35VU:
R - push, release and push again the GEN 1 pushbutton switch (3XU1).

R (3) Do the operational test of the GAPCU (Ref. AMM TASK 24-41-00-740-R 002).

R (4) Start the engine 1 (Ref. AMM TASK 71-00-00-710-003).

R (5) Do this test:

R -------------------------------------------------------------------------------R ACTION RESULT
R -------------------------------------------------------------------------------
R On the ECAM control panel: On the lower ECAM DU:
R - get the ELEC page. - the correct electrical parameters of
R the GEN 1 are shown and the AC1
R busbar is supplied by the GEN 1.

R 5. Close-up

________ R A. Put the aircraft back to its initial configuration. R (1) Stop the engine 1 (Ref. AMM TASK 71-00-00-710-028). R (2) Do the EIS stop procedure
R (Ref. AMM TASK 31-60-00-860-002).
R (3) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY
R potentiometers to OFF.

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 401-499, ∞∞24-20-00∞∞∞∞∞∞∞∞∞∞Page B251
 Aug 01/05 CESR (4) De-energize the aircraft electrical circuits R (Ref. AMM TASK 24-41-00-862-002).

 

R TASK 24-20-00-810-905


R Low Oil Pressure of the Integrated Drive Generator 2 R 1. Possible Causes
_______________
R - IDG (4000XU) R - GCU-2 (1XU2) R - wiring
 