 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-21-51-000-040 Removal of the Integrated Drive Generator -IDG 1(2),(4000XU) AMM 24-21-51-400-040 Installation of the Integrated Drive Generator -IDG
 1(2),(4000XU) AMM 24-22-34-000-001 Removal of the GCU-1(2) (1XU1, 1XU2) AMM 24-22-34-400-001 Installation of the GCU-1(2) (1XU1, 1XU2) AMM 24-41-00-740-002 Operational Test of the Ground power Control Unit
 (GPCU)
 ASM 24-21/01

 3. Fault Confirmation
__________________
 A. Test Do the operational test of the GPCU (Ref. AMM TASK 24-41-00-740-002).
 4. Fault Isolation
_______________
 CAUTION : BEFORE YOU START THE CHECK OF IDG WIRING THAT INCLUDES CONNECTORS,
_______ EXAMINE EACH CONNECTOR TO MAKE SURE THAT THERE IS NO OIL IN IT. IF YOU FIND OIL, CLEAN THE CONNECTOR AND CONNECT IT AGAIN. IF THE FAILURE CONTINUES, DO THE TROUBLE SHOOTING PROCEDURE AS GIVEN BELOW.
 A. If the test gives the maintenance message CHECK GCU2 PIN A9A, A9B IDG2 PIN B9, B8 WIRING:
 - do a check of the wiring for open circuit or short to ground between respectively the IDG 2 pins B/9, B/8 and the GCU 2 pins A/9A, A/9B (Ref. ASM 24-21/01).
 (1) If the wiring is not correct:
 - repair it.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞24-21-00∞∞∞∞∞∞∞∞∞∞Page 211
 201-299, 301-399, Aug 01/05 CES (2) If the wiring is correct:


 - do a check of the resistance between the pins B/8 and B/9 of the IDG 2.
 NOTE : The normal value is 99.1 Ohms plus or minus 5 Ohms at 25.C.
____
 (a) If the resistance value is out of the specified limits:

 - replace the IDG (4000XU) (Ref. AMM TASK 24-21-51-000-040) and (Ref. AMM TASK 24-21-51-400-040).

 (b) If the resistance value is in the specified limits:


 - replace the GCU-2 (1XU2) (Ref. AMM TASK 24-22-34-000-001) and (Ref. AMM TASK 24-22-34-400-001).
 B. Do the test given in Para. 3.
 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1R EFF : 001-049, 051-099, 101-149, 151-199, ∞∞24-21-00∞∞∞∞∞∞∞∞∞∞Page 212
 201-299, 301-399, Aug 01/05 CES

 TASK 24-21-00-810-807


 Difference in IDG 1 Oil-In/Oil-Out Bulb Tolerances
 1. Possible Causes
_______________
 - IDG (4000XU)

 - GCU-1 (1XU1)

 - wiring


 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
AMM 24-21-51-000-040 Removal of the Integrated Drive Generator -IDG 1(2),(4000XU) AMM 24-21-51-400-040 Installation of the Integrated Drive Generator -IDG
 1(2),(4000XU)
 AMM 24-22-34-000-001 Removal of the GCU-1(2) (1XU1, 1XU2)
 AMM 24-22-34-400-001 Installation of the GCU-1(2) (1XU1, 1XU2)
 ASM 24-21/01

 3. Fault Confirmation
__________________
 A. Test
 Not applicable.

 NOTE : The BITE test permits to do a check of the GCU only. The fault
____ confirmation related to IDG 1 BULB TOLERANCE is not possible on ground.
 4. Fault Isolation
_______________
 CAUTION : BEFORE YOU START THE CHECK OF IDG WIRING THAT INCLUDES CONNECTORS,
_______ EXAMINE EACH CONNECTOR TO MAKE SURE THAT THERE IS NO OIL IN IT. IF YOU FIND OIL, CLEAN THE CONNECTOR AND CONNECT IT AGAIN. IF THE FAILURE CONTINUES, DO THE TROUBLE SHOOTING PROCEDURE AS GIVEN BELOW.
 A. If the fault symptom is identified by the CFDS message IDG 1 BULB TOLERANCE and the upper ECAM DU warning IDG 1 OIL OVHT:
 - do a check of the wiring: . for open circuit between the GCU 1 pin A/9A and the IDG 1 pin B/9 . for short to ground between the GCU 1 pin A/8A and the IDG 1 pin B/7 . for wire cross-connection between respectively the GCU 1 pins A/8A, A/9A, A/9B and the IDG 1 pins B/7, B/9, B/8 (Ref. ASM 24-21/01).