• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-28 09:47来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

R  . IDG1 (E1-4000XU) OIL OUT TEMP SENSE / GCU1 (1XU1) 
R  (1) If one or two of the CFDS messages are given: 
R  - replace the engine 1 IDG (4000XU) (Ref. AMM TASK 24-21-51-000-040) 
R  and (Ref. AMM TASK 24-21-51-400-040). 
R  (2) If these CFDS messages are not given: 
R  - do a check of the resistance of the Current Transformer (CT) 
R  (51XU1) (Ref. ASM 24-22/01) between: 
R  . pins 1 and 4 (10.15 ohms plus or minus 3.45 ohms) 
R  . pins 2 and 4 (10.15 ohms plus or minus 3.45 ohms) 
R  . pins 3 and 4 (10.15 ohms plus or minus 3.45 ohms). 
R  (a) If the resistance values are out of the specified limits: 
R  - replace the CT (51XU1) (Ref. AMM TASK 24-22-17-000-001) and 
R  (Ref. AMM TASK 24-22-17-400-001). 
R  (b) If the resistance values are in the specified limits: 
R  - do a check of the wiring (Ref. ASM 24-22/01) for a short to 
R  ground, a short circuit or an open circuit between: 
R  . pin 1 of the CT and pin A/12B of the GCU 1 
R  . pin 2 of the CT and pin A/12A of the GCU 1 
R  . pin 3 of the CT and pin A/11A of the GCU 1 
R  . pin 4 of the CT and pin A/11B of the GCU 1. 
R  1 If the wiring is not correct:_ 
R  - repair or replace as necessary. 
R  2 If the wiring is correct:_ 
R  - replace the GCU-1 (1XU1) (Ref. AMM TASK 24-22-34-000-001) 
R  and (Ref. AMM TASK 24-22-34-400-001). 
R  B. Do this operational test to make sure that the system operates correctly. 
R  (1) Aircraft Maintenance Configuration 
R  (a) Energize the aircraft electrical circuits 
R  (Ref. AMM TASK 24-41-00-861-002). 
R  (b) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) 
R  (Ref. AMM TASK 31-60-00-860-001). 
R  (2) On the ELEC panel 35VU: 
R  - push, release and push again the GEN 1 pushbutton switch (3XU1).

 「一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一一1 EFF : 401-499, ∞∞24-22-00∞∞∞∞∞∞∞∞∞∞Page 258
 Aug 01/05 CES


R  (3) Do the operational test of the GAPCU (Ref. AMM TASK 24-41-00-740-
R  002). 
R  (4) Start the engine 1 (Ref. AMM TASK 71-00-00-710-003). 
R  (5) Do this test: 
R  -------------------------------------------------------------------------------
R  ACTION  RESULT 
R  -------------------------------------------------------------------------------
R  On the ECAM control panel:  On the lower ECAM DU: 
R  - get the ELEC page.  - the correct electrical parameters of 
R  the GEN 1 are shown and the AC1 
R  busbar is supplied by the GEN 1. 
R  5. Close-up________ 
R  A. Put the aircraft back to its initial configuration. 
R  (1) Stop the engine 1 (Ref. AMM TASK 71-00-00-710-028). 
R  (2) Do the EIS stop procedure 
R  (Ref. AMM TASK 31-60-00-860-002). 
R  (3) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY 
R  potentiometers to OFF. 
R  (4) De-energize the aircraft electrical circuits 
R  (Ref. AMM TASK 24-41-00-862-002).


R TASK 24-22-00-810-820


R Failure of the Current Transformer 2 R 1. Possible Causes
_______________
R - IDG (4000XU) R - CT (51XU2) R - GCU-2 (1XU2) R - wiring
R 2. Job Set-up Information
______________________
R A. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R AMM 24-21-51-000-040 R R AMM 24-21-51-400-040 R R AMM 24-22-17-000-001 R R AMM 24-22-17-400-001 R R AMM 24-22-34-000-001 R AMM 24-22-34-400-001 R AMM 24-41-00-740-002 R AMM 24-41-00-861-002 R R AMM 24-41-00-862-002 R R AMM 31-60-00-860-001 R AMM 31-60-00-860-002 R AMM 71-00-00-710-003 R AMM 71-00-00-710-028 R ASM 24-22/01
R 3. Fault Confirmation
__________________
R A. Test
R Not applicable.

Removal of the Integrated Drive Generator -IDG 1(2),(4000XU) Installation of the Integrated Drive Generator -IDG 1(2),(4000XU) Removal of the AC Current Transformers (41XU1, 41XU2, 51XU1, 51XU2) Installation of the AC Current Transformers (41XU1, 41XU2, 51XU1, 51XU2) Removal of the GCU-1(2) (1XU1, 1XU2) Installation of the GCU-1(2) (1XU1, 1XU2) Operational Check of GAPCU via CFDS Energize the Aircraft Electrical Circuits from the External Power De-energize the Aircraft Electrical Circuits Supplied from the External Power EIS Start Procedure EIS Stop Procedure Engine Automatic Start Engine Shutdown
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 Trouble Shooting Manual 排故手册 电源 2(151)