• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-21 13:53来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 Compartment 25-54-12-400-001 Installation of the FWD Cargo Compartment Partition FR34 25-54-12-400-002 Installation of the Ceiling Panels in the FWD Cargo Compartment 25-55-11-000-002 Removal of the Ceiling Panels in the AFT Cargo Compartment - FR47/FR59


 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
25-55-11-400-002 Installation of the Ceiling Panels in the AFT Cargo
 Compartment -FR47/FR59 25-55-12-000-001 Removal of the AFT Cargo Compartment Partition FR65 25-55-12-000-002 Removal of the Ceiling Panels in the AFT Cargo
 Compartment - FR59/FR65 25-55-12-400-001 Installation of the AFT Cargo Compartment Partition FR65 25-55-12-400-002 Installation of the Ceiling Panels in the AFT Cargo Compartment - FR59/FR65 53-12-11-000-001 Removal of the Cockpit Floor Panels from FR1 Thru FR12 53-12-11-400-001 Installation of the Cockpit Floor Panels from FR1
 thru FR12 53-12-12-000-001 Removal of the Cabin Floor Panels from FR12 thru FR24 53-12-12-400-001 Installation of the Cabin Floor Panels from FR12 thru
 FR24
 53-22-12-000-001 Removal of the Cabin Floor Panels
 53-22-12-400-001 Installation of the Cabin Floor Panels
 53-32-12-000-002 Removal of the Cabin Floor Panels
 53-32-12-400-002 Installation of the Cabin Floor Panels
 27-41-00-991-010 Fig. 601

 3. Job Set-up
__________

R **ON A/C 001-003, 051-053,
 Subtask 27-41-00-010-050
 A. Get Access
 (1)
 Put the ACCESS PLATFORM 2M (6 FT) in position at the zone 121.

 (a) Open the access door 811.

 (2)
 Put the ACCESS PLATFORM 2M (6 FT) in position at the zone 132.

 (a) Open the access door 825.

 (3)
 Put the ACCESS PLATFORM 2M (6 FT) in position at the zone 154.

 (a) Open the access door 826.

 (4)
 Put the ACCESS PLATFORM 2M (6 FT) in position at the zone 312.

 (a) Open the access door 312AR.

 (5)
 In the zones 211 and 221, remove the floor panels 211GF, 211KF, 221AF, 221EF (Ref. TASK 53-12-11-000-001) and (Ref. TASK 53-12-12-000-001).

 (6)
 In the zones 231 and 241, remove the floor panels 231CF, 231WF, 241BF, 241FF, 241KF (Ref. TASK 53-12-12-000-001) (Ref. TASK 53-22-12-000-001) (Ref. TASK 53-32-12-000-002).

 (7)
 In the zone 131, remove the ceiling panels 131AC, 131BC, 131CC (Ref. TASK 25-54-12-000-002).

 (8)
 In the zone 131, remove the partition panel 131PW (Ref. TASK 25-54-12-000-001).

 (9)
 In the zones 151 and 161, remove the ceiling panels 151AC, 151BC, 151CC, 151DC, 161AC, 161BC (Ref. TASK 25-55-11-000-002) (Ref. TASK 25-55-12-000-002).

 


 (10) In the zone 161, remove the partition panels 161DW, 162DW (Ref. TASK 25-55-12-000-001).

R **ON A/C 151-199, 401-499,
 Subtask 27-41-00-010-050-C
 A. Get Access
 (1)
 Put the ACCESS PLATFORM 2M (6 FT) in position at the zone 121.

 (a) Open the access door 811.

 (2)
 Put the ACCESS PLATFORM 2M (6 FT) in position at the zone 132.

 (a) Open the access door 825.

 (3)
 Put the ACCESS PLATFORM 2M (6 FT) in position at the zone 154.

 (a) Open the access door 826.

 (4)
 Put the ACCESS PLATFORM 2M (6 FT) in position at the zone 312.


 (a) Open the access door 312AR.
R 1EFF : 001-003, 051-053, 151-199, 401-499, 1 27-41-00Page 603 1 1 Aug 01/05 1 1 1CES 1


 (5)
 In the zones 211 and 221, remove the floor panels 211GF, 211KF, 221EF 221LF (Ref. TASK 53-12-11-000-001) and (Ref. TASK 53-12-12-000-001).

 (6)
 In the zones 231 and 241, remove the floor panels 231CF, 231WF, 241BF, 241FF, 241KF (Ref. TASK 53-12-12-000-001) (Ref. TASK 53-22-12-000-001) (Ref. TASK 53-32-12-000-002).

 (7)
 In the zone 131, remove the ceiling panels 131KC, 131MC, 131NC (Ref. TASK 25-54-12-000-002).

 (8)
 In the zone 131, remove the partition panel 131PW (Ref. TASK 25-54-12-000-001).

 (9)
 In the zones 151 and 161, remove the ceiling panels 151EC, 151FC, 151GC, 161AC, 161BC (Ref. TASK 25-55-11-000-002) (Ref. TASK 25-55-12-000-002).


 (10) In the zone 161, remove the partition panels 161DW, 162DW (Ref. TASK 25-55-12-000-001). **ON A/C 001-049, 054-099, 101-149, 201-299, 301-399,
 Post SB 53-1143 For A/C 001-003, Subtask 27-41-00-010-050-B
 A. Get Access
 (1)
 Put the ACCESS PLATFORM 2M (6 FT) in position at the zone 121.

 (a) Open the access door 811.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FLIGHT CONTROLS 飞行操纵3(94)