(2)
Make sure that the hydraulic systems are depressurized (Ref. TASK 29-10-00-864-001), (Ref. TASK 29-10-00-864-002), (Ref. TASK 29-10-00-864-003).
(3)
Make sure that the PIN-SIDE STICK LOCKING (98D27903500000) is in the CAPT and F/O side stick controllers.
(4)
Make sure that the TOOL-ELEVATOR NEUTRAL SETTING (98D27309001000) is installed on the elevators.
(5)
Make sure that the warning notices are in the flight compartment to tell persons not to operate the flight controls.
1EFF : ALL 1 27-34-51Page 448 1 1 May 01/05R 1 1 1CES 1
(6)
Make sure that the warning notices are in position to tell persons not to operate the hydraulic systems.
(7)
Make sure that the access platforms are in position at zone 334 and/or zone 344.
(8)
Make sure that the access panels 334DB and/or 344DB are open (Ref. TASK 55-13-11-000-001).
Subtask 27-34-51-865-078
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FLIGHT CONTROLS/ELAC1/NORM/SPLY 15CE1 B11 49VU FLIGHT CONTROLS/FCDC1/SPLY 20CE1 B10 49VU FLIGHT CONTROLS/THS/ACTR/MOT2 19CE2 B09 49VU FLIGHT CONTROLS/SEC1/NORM/SPLY 21CE1 B08 105VU FLIGHT CONTROLS/ELAC2/STBY SPLY 16CE2 A02 105VU FLT CTL/ELAC1/STBY SPLY 16CE1 A01 105VU FLT CTL/SEC1/STBY SPLY 22CE B01 121VU FLIGHT CONTROLS/FCDC2/SPLY 20CE2 Q20 121VU FLIGHT CONTROLS/SEC2/SPLY 21CE2 Q18 121VU FLIGHT CONTROLS/THS ACTR/MOT3 19CE3 Q17 121VU FLIGHT CONTROLS/THS ACTR/MOT1 19CE1 Q16 121VU FLIGHT CONTROLS/ELAC2/NORM/SPLY 15CE2 R20
Subtask 27-34-51-140-053
C. Cleaning
(1)
Clean the component interface and/or the adjacent area.
(2)
Make sure that the parts retained from the removed component are clean and in the correct condition.
1EFF : ALL 1 27-34-51Page 449 1 1 May 01/05R 1 1 1CES 1
4. Procedure
_________
(Ref. Fig. 405/TASK 27-34-51-991-004) Subtask 27-34-51-420-055
A. Install the servo control actuator solenoid valves
(Ref. Fig. 405/TASK 27-34-51-991-004)
WARNING : WEAR GOGGLES WHEN YOU REMOVE OR INSTALL THE LOCKWIRE. CUT,
_______ REMOVE AND DISCARD THE LOCKWIRE AS YOU DO THE TASK. LOOSE LOCKWIRE CAN CUT OR BLIND YOU.
NOTE : There are two solenoid valves on each servo control unit, they are
____ shown as Solenoid Valve No. 1 and Solenoid Valve No. 2.
(1)
Remove the protective plate to the solenoid valve mounting face (Ref. AIPC 27345101230).
(2)
Put the O ring (2) in position on the solenoid valve (3).
(3)
Put the solenoid valve (3) in position on the servo-control actuator and support it.
(4)
Install the bolts (4) into the solenoid valve (3).
(5)
TORQUE the bolts (4) to between 0.33 and 0.41 m.daN (29.20 and 36.28 lbf.in)
(6)
Safety the bolts (4) with lockwire, corrosion resistant steel 0,6mm (0.027in) dia.
(7)
Connect the electrical connectors.
(a) Remove the blanking caps.
(b) Connect the electrical connectors (1). Subtask 27-34-51-081-052
B. Remove Locking Devices
(1)
Remove the PIN-SIDE STICK LOCKING from the CAPT and the F/O side stick controllers.
(2)
Remove the SETTING TOOL-NEUTRAL, ELEVATOR from the elevator.
1EFF : ALL 1 27-34-51Page 450 1 1 May 01/05R 1 1 1CES 1
Subtask 27-34-51-865-057
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 15CE1, 15CE2, 16CE1, 16CE2, 19CE1, 19CE2, 19CE3, 20CE1, 20CE2, 21CE1, 21CE2, 22CE
Subtask 27-34-51-710-052
D. Operational Test
(1) Do an operational test of the servo controls. (Ref. TASK 27-34-00-710-001)
5. Close-up
________ Subtask 27-34-51-410-054
A. Visual Inspection
(1) Make sure that the work area is clean and clear of tool(s) and other items.
Subtask 27-34-51-420-056
B. Close Access
(1) Close the trailing edge access panels 334DB and/or 344DB. (Ref. TASK 55-13-11-400-001)
Subtask 27-34-51-942-054
C. Remove Ground Equipment
(1)
Remove the warning notice(s).
(2)
Remove the access platform(s).
1EFF : ALL 1 27-34-51Page 451 1 1 May 01/05R 1 1 1CES 1
TASK 27-34-51-000-006
Removal of the Elevator Servo Control Actuator Mode Selector Valve Transducer MSVT WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FLIGHT CONTROLS 飞行操纵3(70)