(2)
Remove the access platform(s).
1EFF : ALL 1 27-34-51Page 441 1 1 Aug 01/05R 1 1 1CES 1
TASK 27-34-51-000-005 Removal of the Elevator Servo Control Actuator Solenoid Valve WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______ GEAR.
WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR.
_______ MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE.
WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROL SURFACES ARE
_______ CLEAR BEFORE YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC SYSTEM.
WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______ START A TASK ON OR NEAR:
-
THE FLIGHT CONTROLS
-
THE FLIGHT CONTROL SURFACES
-
THE LANDING GEAR AND THE RELATED DOORS
-COMPONENTS THAT MOVE. WARNING : WEAR AND ATTACH A SAFETY HARNESS WHEN YOU WORK ON HIGH SECTIONS. A
_______ FALL CAN INJURE OR KILL YOU.
CAUTION : DO NOT CAUSE DAMAGE TO THE SURFACES. THE COMPONENTS ARE MADE OF
_______ CARBONFIBER REINFORCED PLASTIC.
NOTE : The removal of the servo control actuator 34CE1 solenoid valve is given.
____ The removal of the servo control actuators 34CE2, 34CE3 and 34CE4 solenoid valves are the same.
1. Reason for the Job__________________ Self Explanatory
1EFF : ALL 1 27-34-51Page 442 1 1 May 01/05R 1 1 1CES 1
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps No specific circuit breaker(s) safety clip(s) No specific warning notices No specific access platform 3.5 m (11 ft. 6 in.) 98D27309001000 1 TOOL-ELEVATOR NEUTRAL SETTING 98D27903500000 2 PIN-SIDE STICK LOCKING
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
29-10-00-864-001 Depressurize the Green Hydraulic System 29-10-00-864-002 Depressurize the Yellow Hydraulic System 29-10-00-864-003 Depressurize the Blue Hydraulic System 55-13-11-000-001 Removal of the THS Trailing Edge Access Panels AIPC 27345101230 27-34-51-991-004 Fig. 405
3. Job Set-up
__________
Subtask 27-34-51-860-064
A. Aircraft Maintenance Configuration
(1) Make sure that the elevator and the horizontal stabilizer controls are set to the neutral position.
Subtask 27-34-51-860-054
B. Depressurize Hydraulic Systems
(1) Make sure that Green, Yellow and Blue hydraulic systems are depressurized (Ref. TASK 29-10-00-864-001) (Ref. TASK 29-10-00-864-002) (Ref. TASK 29-10-00-864-003).
1EFF : ALL 1 27-34-51Page 443 1 1 May 01/05R 1 1 1CES 1
Subtask 27-34-51-865-056
C. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU FLIGHT CONTROLS/ELAC1/NORM/SPLY 15CE1 B11 49VU FLIGHT CONTROLS/FCDC1/SPLY 20CE1 B10 49VU FLIGHT CONTROLS/THS/ACTR/MOT2 19CE2 B09 49VU FLIGHT CONTROLS/SEC1/NORM/SPLY 21CE1 B08 105VU FLIGHT CONTROLS/ELAC2/STBY SPLY 16CE2 A02 105VU FLT CTL/ELAC1/STBY SPLY 16CE1 A01 105VU FLT CTL/SEC1/STBY SPLY 22CE B01 121VU FLIGHT CONTROLS/FCDC2/SPLY 20CE2 Q20 121VU FLIGHT CONTROLS/SEC2/SPLY 21CE2 Q18 121VU FLIGHT CONTROLS/THS ACTR/MOT3 19CE3 Q17 121VU FLIGHT CONTROLS/THS ACTR/MOT1 19CE1 Q16 121VU FLIGHT CONTROLS/ELAC2/NORM/SPLY 15CE2 R20
Subtask 27-34-51-481-051
D. Install Locking Devices
(1)
Put the PIN-SIDE STICK LOCKING (98D27903500000) in the CAPT and F/O side stick controllers.
(2)
Install the TOOL-ELEVATOR NEUTRAL SETTING (98D27309001000) on the elevator.
Subtask 27-34-51-941-054
E. Safety Precautions
(1)
Put the warning notices in the flight compartment to tell persons not to operate the flight controls.