• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-21 13:53来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

_______ THE TASK. ISOLATE THE OTHER HYDRAULIC SYSTEM(S) BEFORE YOU SUPPLY HYDRAULIC POWER TO THE AIRCRAFT.
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific container
 No specific warning notices
 No specific adjustable access platform 6.0 m (19 ft. 8 in.)

R No specific Torque Wrench : range 0.00 to 1.20 m.daN
R (0.00 to 9.00 lbf.ft) 98D27207516000 1 RIGGING PIN SET 98D27207549000 1 PIN - RIGGING


 B. Consumable Materials
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
No specific  lockwire, corrosion-resistant steel, dia. 0.8 mm
 (0.032 in.)
R Material No. 02-003  F NSA 307110 TYPE 4 HYDRAULIC FLUID (PHOSPHATE ESTER BASE) (Ref. 20-31-00)
 Material No. 05-002  USA MIL-P-8116 PUTTY, ZINC CHROMATE GENERAL PURPOSE (Ref. 20-31-00)
 C. Expendable Parts
 -------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION  |IPC-CSN
 -------------------------------------------------------------------------------
4 O-ring 27-26-51 01 -100 5 O-ring 27-26-51 01 -110 6 O-ring 27-26-51 01 -120 9 O-ring 27-26-51 01 -130
 D. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
22-63-00-710-001 Operational Test of the Yaw Damper Function 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
 Configuration before Maintenance Action 29-00-00-910-002 Safety Procedures of the Hydraulic System 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs 29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
 the Ground Connector
 55-33-13-010-002  Opening/Removal of the Trailing Edge Access-Panels 325EL, 325ER, 325DL, 325DR, 325CL, 325CR, 325BL and 325BR
 55-33-13-410-002  Closing/Installation of the Trailing Edge Access-Panels 325EL, 325ER, 325DL, 325DR, 325CL, 325CR, 325BL and 325BR
 27-26-51-991-002  Fig. 402 3. Job Set-up


__________
 Subtask 27-26-51-860-056-A
 A. Aircraft Maintenance Configuration
 WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
 (1)
 Obey the hydraulic safety procedures (Ref. TASK 29-00-00-910-002).

 (2)
 Make sure that the adjustable access platform is in position at zone


 325.
R (3) Make sure that the access panel 325BL (for the solenoid valve on R 3CC1) or 325BR (for the solenoid valve on 3CC2) is open (Ref. TASK 55-33-13-010-002).
 (4)
 Make sure that the rudder pedals are in the neutral position.

 (5)
 Make sure that the RUD TRIM indicator on the center pedestal, on the panel 110VU shows 0.

 (6)
 Make sure that the warning notices are in position in the cockpit to tell persons not to operate the flight controls.

 (7)
 Make sure that the hydraulic systems are depressurized and put them in the maintenance configuration. (Ref. TASK 29-00-00-864-001).

 (8)
 Make sure that the reservoirs of the Green and Yellow hydraulic systems are depressurized (Ref. TASK 29-14-00-614-001).

 (9)
 Make sure that the aircraft electrical circuits are de-energized (Ref. TASK 24-41-00-862-002).


 (10) Make sure that the warning notices are in position to tell persons not to pressurize the Green, the Yellow and the Blue hydraulic systems:
 -in the cockpit on the hydraulic section 40VU of the overhead panel,
 - on the ground service panels of the Green, Yellow and Blue hydraulic systems.
 (11)
 Make sure that the PIN - RIGGING 98D27207516330, part of the RIGGING PIN SET (98D27207516000), or the PIN - RIGGING (98D27207549000) is in position in the yaw damper bellcrank.

 (12)
 Make sure that the container is in position below the yaw damper to collect unwanted fluid.

 


 Subtask 27-26-51-865-057
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FLIGHT CONTROLS 飞行操纵3(7)