-lift the guard and push the HYD/LEAK MEASUREMENT VALVES/Y pushbutton switch.
 5. On the center pedestal:
-turn the pitch-trim control wheel to the nose DN stop position and then to the nose UP stop position.
6. On the panel 50VU:
-lift the guard and release the HYD/LEAK MEASUREMENT VALVES/Y and push the HYD/LEAK MEASUREMENT VALVES/G pushbutton switches.
 7. On the center pedestal:
-turn the pitch-trim control wheel to the nose DN stop and then to the O position.
8. On the panel 50VU:
-lift the guard and push the HYD/LEAK MEASUREMENT VALVES/Y pushbutton switch.
The THS does not move.
On the F/CTL page of the lower ECAM DU:
 -
the PITCH TRIM indication shows no movement.

On the panel 50VU:

-
the OFF legend on the Y pushbuttonswitch goes off.


The THS moves to the nose fully downand then to the nose fully up position.
On the F/CTL page of the lower ECAM DU:
-
the PITCH TRIM indication shows the movement of the THS in both directions.

On the panel 50VU:

-
the OFF legend on the Y pushbuttonswitch comes on.

-
the OFF legend on the G pushbuttonswitch goes off.


The THS moves to the fully nose downposition and stop at the O position.
On the lower ECAM DU, on the F/CTL page:
 -
the PITCH TRIM indication shows the movement of the THS.

On the panel 50VU:

-
the OFF legend on the Y pushbuttonswitch goes off.


 1EFF : ALL 1 27-44-00Page 528 1 1 Feb 01/03R 1 1 1CES 1


 5. Close-up
________ Subtask 27-44-00-860-056
 A. Put the aircraft back to the serviceable condition.
 (1)
 Depressurize the Green and Yellow hydraulic systems. (Ref. TASK 29-23-00-864-001).

 (2)
 Do the EIS stop procedure
 (Ref. TASK 31-60-00-860-002).


 (3)
 De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).

 


 ACTUATOR - THS (9CE) - REMOVAL/INSTALLATION
___________________________________________
 TASK 27-44-51-000-001
 Removal of the Trimmable Horizontal Stabilizer (THS) Actuator (9CE)
 WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
 START A TASK ON OR NEAR:

 -
THE FLIGHT CONTROLS

 -
THE FLIGHT CONTROL SURFACES

 -
THE LANDING GEAR AND THE RELATED DOORS


 -COMPONENTS THAT MOVE.
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific adhesive tape
 No specific blanking caps
 No specific circuit breaker(s) safety clip(s)
 No specific covers (resistant against hydraulic fluid)
 No specific protective padding
 No specific step 0.3 m/1.3 ft.
 No specific structural protection material
 No specific warning notices
 No specific drainage container 4.0 l (1.0566 USgal)
 No specific access platform 5.5 m (18 ft. 1 in.)

R  A1-91-265 1 HOIST - MINILIFT A3-91-267 1 HOIST - MINILIFT, THS ACTUATOR 0U145920 1 TOOL - MANUAL CRANKING STOP, THS ACTUATOR 0U190360 1 PIN - RIGGING 0U190834 1 TOOL - ZERO POSITIONING, THS ACTUATOR 0U190844 2 RELEASE TOOL - PRESSURE-OFF BRAKE, THS ACTUATOR 98D27403500000 1 PITCH TRIM CONTROL LOCKING 98D27407502000 1 SUPPORT STRUT - R/I THS ACTUATOR 98D27407506000 1 DEVICE - R/I THS ACTUATOR 98D27407533000 1 FRAME - THS ACTUATOR SUPPORT


 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE  DESIGNATION
 -------------------------------------------------------------------------------
27-44-51-710-001 Operational Test of the No-Back Device (No-Back Pawls) 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
 Configuration before Maintenance Action 29-00-00-910-002 Safety Procedures of the Hydraulic System 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs 29-23-00-863-001 Pressurize the Green Hydraulic System from the Yellow
 Hydraulic System through the PTU with the Electric Pump
 29-23-00-863-002  Pressurize the Yellow Hydraulic System from the Green Hydraulic System through the PTU with the Ground Service Cart
 27-44-51-991-001 Fig. 401
 27-44-51-991-002 Fig. 402
 27-44-51-991-003 Fig. 403
 