the ELAC 2 indication becomes amber.

 -
the indication of the elevators position is in amber crosses.


 On the ground, visually make sure that the elevators are in the neutral position.
On the overhead panel 24VU:
-
the OFF legend of the FLT CTL/ELAC 2pushbutton switch goes off.

 -
the FAULT legend of the FLT CTL/ELAC 2 pushbutton switch comes on then goes off.


On the lower ECAM display unit, on theF/CTL page:
 1EFF : ALL 1 27-34-00Page 510 1 1 May 01/00R 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-push the side stick controller forward until it touches the stop. Hold it in this position.
 6. On the overhead panel 24VU:
-release the FLT CTL/ELAC 2 pushbutton switch.
7. On the CAPT (F/O) lateral console:
 -move and keep the side stick controller in the neutral position.
 8. On the overhead panel 23VU:
-push the FLT CTL/ELAC 1
pushbutton switch.

9. On the maintenance panel 50VU:
-push the HYD LEAK MEASUREMENT VALVES/B pushbutton switch.
-release the HYD LEAK MEASUREMENT VALVES/G and HYD LEAK MEASUREMENT VALVES/Y pushbutton switches.
10. On the lower ECAM display unit, on the F/CTL page:
 -make sure that the indexes of the L/ELEV and R/ELEV
-
the indexes of the L/ELEV and R/ELEVindicators move down.

On the overhead panel 24VU:

-
the OFF legend of the FLT CTL/ELAC 2pushbutton switch comes on.

 On the lower ECAM display unit, on the F/CTL page:

 -
the ELAC 2 indication becomes amber.

 -
the indication of the elevators position is in amber crosses.


 On the ground, visually make sure that the elevators are in neutral position.
On the overhead panel 23VU:
-
the OFF legend of the FLT CTL/ELAC 1pushbutton switch goes OFF.

 -
the FAULT legend of the FLT CTL/ELAC 1 pushbutton switch comes on then goes off.

On the maintenance panel 50VU:

-
the OFF legend of the HYD LEAKMEASUREMENT VALVES/B pushbuttonswitch goes off.

-
the OFF legends of the HYD LEAKMEASUREMENT VALVES/G and HYD LEAKMEASUREMENT VALVES/Y pushbutton switches come on.


 1EFF : ALL 1 27-34-00Page 511 1 1 May 01/00R 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
indicators are in the neutral position.
 11. On the CAPT (F/O) lateral console:
-pull the side stick controller rearward until it touches the stop. Hold it in this position.
 12. On the overhead panel 23VU:
-release the FLT CTL/ELAC 1 pushbutton switch.
13. On the CAPT (F/O) lateral console:
 -move and keep the side stick controller in the neutral position.
 14. On the overhead panel 23VU:
-push the FLT CTL/ELAC 1 pushbutton switch.
15. On the CAPT (F/O) lateral console:
-push the side stick controller forward until it touches the stop. Hold it in this position.
On the lower ECAM display unit, on theF/CTL page:
-
the indexes of the L/ELEV and R/ELEVindicators move up.

On the overhead panel 23VU:

-
the OFF legend of the FLT CTL/ELAC 1pushbutton switch comes on.

 On the lower ECAM display unit, on the F/CTL page:

 -
the ELAC 1 indication becomes amber.

 -
the indication of the elevators position is in amber crosses.


 On the ground, visually make sure that the elevators are in the neutral position.
On the overhead panel 23VU:
-
the OFF legend of the FLT CTL/ELAC 1pushbutton switch goes off.

 -
the FAULT legend of the FLT CTL/ELAC 1 pushbutton switch comes on then goes off.

On the lower ECAM display unit, on theF/CTL page:

-
the indexes of the L/ELEV and R/ELEVindicators move down.


 1EFF : ALL 1 27-34-00Page 512 1 1 May 01/00R 1 1 1CES 1


 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
16. On the overhead panel 23VU: On the overhead panel 23VU:
 -release the FLT CTL/ELAC 1  - the OFF legend of the FLT CTL/ELAC 1 pushbutton switch. pushbutton switch comes on.
 On the lower ECAM display unit, on the F/CTL page:
 -
the ELAC 1 indication becomes amber.

 -
the indication of the elevators position is in amber crosses.


 On the ground, visually make sure that the elevators are in the neutral position.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FLIGHT CONTROLS 飞行操纵3(22)