the ELAC 2 indication becomes amber.
-
the indication of the elevators position is in amber crosses.
On the ground, visually make sure that the elevators are in the neutral position.
On the overhead panel 24VU:
-
the OFF legend of the FLT CTL/ELAC 2pushbutton switch goes off.
-
the FAULT legend of the FLT CTL/ELAC 2 pushbutton switch comes on then goes off.
On the lower ECAM display unit, on theF/CTL page:
1EFF : ALL 1 27-34-00Page 510 1 1 May 01/00R 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-push the side stick controller forward until it touches the stop. Hold it in this position.
6. On the overhead panel 24VU:
-release the FLT CTL/ELAC 2 pushbutton switch.
7. On the CAPT (F/O) lateral console:
-move and keep the side stick controller in the neutral position.
8. On the overhead panel 23VU:
-push the FLT CTL/ELAC 1
pushbutton switch.
9. On the maintenance panel 50VU:
-push the HYD LEAK MEASUREMENT VALVES/B pushbutton switch.
-release the HYD LEAK MEASUREMENT VALVES/G and HYD LEAK MEASUREMENT VALVES/Y pushbutton switches.
10. On the lower ECAM display unit, on the F/CTL page:
-make sure that the indexes of the L/ELEV and R/ELEV
-
the indexes of the L/ELEV and R/ELEVindicators move down.
On the overhead panel 24VU:
-
the OFF legend of the FLT CTL/ELAC 2pushbutton switch comes on.
On the lower ECAM display unit, on the F/CTL page:
-
the ELAC 2 indication becomes amber.
-
the indication of the elevators position is in amber crosses.
On the ground, visually make sure that the elevators are in neutral position.
On the overhead panel 23VU:
-
the OFF legend of the FLT CTL/ELAC 1pushbutton switch goes OFF.
-
the FAULT legend of the FLT CTL/ELAC 1 pushbutton switch comes on then goes off.
On the maintenance panel 50VU:
-
the OFF legend of the HYD LEAKMEASUREMENT VALVES/B pushbuttonswitch goes off.
-
the OFF legends of the HYD LEAKMEASUREMENT VALVES/G and HYD LEAKMEASUREMENT VALVES/Y pushbutton switches come on.
1EFF : ALL 1 27-34-00Page 511 1 1 May 01/00R 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
indicators are in the neutral position.
11. On the CAPT (F/O) lateral console:
-pull the side stick controller rearward until it touches the stop. Hold it in this position.
12. On the overhead panel 23VU:
-release the FLT CTL/ELAC 1 pushbutton switch.
13. On the CAPT (F/O) lateral console:
-move and keep the side stick controller in the neutral position.
14. On the overhead panel 23VU:
-push the FLT CTL/ELAC 1 pushbutton switch.
15. On the CAPT (F/O) lateral console:
-push the side stick controller forward until it touches the stop. Hold it in this position.
On the lower ECAM display unit, on theF/CTL page:
-
the indexes of the L/ELEV and R/ELEVindicators move up.
On the overhead panel 23VU:
-
the OFF legend of the FLT CTL/ELAC 1pushbutton switch comes on.
On the lower ECAM display unit, on the F/CTL page:
-
the ELAC 1 indication becomes amber.
-
the indication of the elevators position is in amber crosses.
On the ground, visually make sure that the elevators are in the neutral position.
On the overhead panel 23VU:
-
the OFF legend of the FLT CTL/ELAC 1pushbutton switch goes off.
-
the FAULT legend of the FLT CTL/ELAC 1 pushbutton switch comes on then goes off.
On the lower ECAM display unit, on theF/CTL page:
-
the indexes of the L/ELEV and R/ELEVindicators move down.
1EFF : ALL 1 27-34-00Page 512 1 1 May 01/00R 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
16. On the overhead panel 23VU: On the overhead panel 23VU:
-release the FLT CTL/ELAC 1 - the OFF legend of the FLT CTL/ELAC 1 pushbutton switch. pushbutton switch comes on.
On the lower ECAM display unit, on the F/CTL page:
-
the ELAC 1 indication becomes amber.
-
the indication of the elevators position is in amber crosses.
On the ground, visually make sure that the elevators are in the neutral position.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FLIGHT CONTROLS 飞行操纵3(22)