Elevator Servo-control Actuator Filter Figure 301/TASK 27-34-42-991-001
1EFF : 1 1R 1CES ALL 1 11 1 27-34-42 Page 305 Feb 01/05
Subtask 27-34-42-420-050
C. Install the Filter WARNING : WEAR GOGGLES WHEN YOU REMOVE OR INSTALL THE LOCKWIRE. CUT,
_______ REMOVE AND DISCARD THE LOCKWIRE AS YOU DO THE TASK. LOOSE LOCKWIRE CAN CUT OR BLIND YOU.
(1)
Install the filter (1) into the supply block (3).
(2)
Safety the filter (1) with lockwire-corrosion resistant steel 0.6mm dia to the supply block (3).
(3)
Remove all signs of hydraulic fluid from the filter area. NOTE : Make sure that the hydraulic fluid is removed if it drops onto
____
components or structure.
Subtask 27-34-42-081-050
D. Remove Locking Devices
(1) Remove the PIN-SIDE STICK LOCKING (98D27903500000) from the CAPT and F/O side stick controllers.
Subtask 27-34-42-865-051
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 19CE1, 19CE2, 19CE3
Subtask 27-34-42-860-051
F. Pressurize Hydraulic Systems
(1) Pressurize the Green, Yellow and Blue hydraulic systems. (Ref. TASK 29-10-00-863-001) (Ref. TASK 29-10-00-863-002) (Ref. TASK 29-10-00-863-003)
1EFF : ALL 1 27-34-42Page 306 1 1 Feb 01/05R 1 1 1CES 1
Subtask 27-34-42-870-050
G. Bleeding
(1) Bleed the elevator servo-control actuators.
(a)
Operate the side stick to move the elevator surfaces.
(b)
Do this ten times and then put the side stick back to the neutral position.
Subtask 27-34-42-210-050
H. Visual Inspection
(1) Make sure that there are no leaks at the joint between the filter (1) and the supply block (3).
5. Close-up
________
Subtask 27-34-42-410-051
A. Visual Inspection
(1) Make sure that the work area is clean and clear of tool(s) and other items.
Subtask 27-34-42-410-050
B. Close Access R (1) Close the trailing-edge access panels 334DB, 344DB (Ref. TASK 55-13-
R 11-400-001). Subtask 27-34-42-611-050
C. Replenish Hydraulic System WARNING : DO NOT GET HYDRAULIC FLUID ON YOUR SKIN, IN YOUR EYES OR IN
_______ YOUR MOUTH. HYDRAULIC FLUID IS POISONOUS AND CAN GO THROUGH YOUR SKIN AND INTO YOUR BODY. FLUSH HYDRAULIC FLUID FROM YOUR EYES, MOUTH OR SKIN WITH WATER. GET MEDICAL AID IF YOU GET HYDRAULIC FLUID IN YOUR EYES OR MOUTH.
(1) If necessary,replenish the hydraulic system (Ref. TASK 12-12-29-611-001).
Subtask 27-34-42-942-051
D. Remove Ground Equipment
(1)
Remove the access platform(s).
(2)
Remove the warning notice(s).
SERVO CONTROL - ELEVATOR (34CE1,34CE2,34CE3,34CE4) - REMOVAL/INSTALLATION
_________________________________________________________________________ TASK 27-34-51-000-001 R Removal of the Elevator Servo Control WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS ARE CLEAR.
_______
MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR
DAMAGE.
WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROL SURFACES ARE
_______
CLEAR BEFORE YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC SYSTEM.
WARNING : MAKE SURE THAT THE CONTROLS AGREE WITH THE POSITION OF THE ITEMS THEY
_______
OPERATE BEFORE YOU PRESSURIZE A HYDRAULIC SYSTEM.
WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU
_______
START A TASK ON OR NEAR:
-
THE FLIGHT CONTROLS
-
THE FLIGHT CONTROL SURFACES
-
THE LANDING GEAR AND THE RELATED DOORS
-COMPONENTS THAT MOVE. WARNING : WEAR AND ATTACH A SAFETY HARNESS WHEN YOU WORK ON HIGH SECTIONS. A
_______
FALL CAN INJURE OR KILL YOU.
WARNING : DO NOT GET THE COMPOUND ON YOUR SKIN.
_______
IF YOU DO:
-RUB IT OFF IMMEDIATELY WITH A CLEAN CLOTH
-WASH THE SKIN WITH SOAP AND RINSE WITH CLEAN WATER.
CAUTION : DO NOT CAUSE DAMAGE TO THE SURFACES. THE COMPONENTS ARE MADE OF
_______
CARBONFIBER REINFORCED PLASTIC.
NOTE : The removal of the servo control unit 34CE1 is given. The removal of the
____
servo control units 34CE2, 34CE3 and 34CE4 is the same.
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FLIGHT CONTROLS 飞行操纵3(57)