dialog box (Figure 113) again with the "NEXT" button enabled.
(d) Put the test setup to the initial condition as follows:
Impedance Selector
SWITCH POSITION
Impedance selector 50W
Tester
· The BNC Tee Adapter T1 (video signal source) is connected to
the VIDEO INPUT CH1 connector.
· The RFC1 cable (spectrum analyzer) is connected to the RF
OUTPUT RF1 connector.
· A BNC 50-W terminator is connected to each of the RF OUTPUT
RF2, RF3 and RF4 connectors.
T&FI-2
Page 143
Feb 20/2002
Matsushita Avionics Systems Corporation
COMPONENT MAINTENANCE MANUAL
PART NUMBER RD-AA5002 SERIES
23-32-47
Oscilloscope
The VC4 cable (CH1 input) is connected to the BNC tee adapter
T1.
VMU Tuner
DISPLAY VALUE
CH 01
FREQ 151.25
(e) Go to step (3) of "A. Start of Tester Program".
(5) Click on the "END" button of the "CHECK RESULTS" window. You will
see the "POWER OFF" box (Figure 116B).
(6) If the problem is related to the RF levels (too high or too low) and
if you think you can correct the problem through adjustments, go to
step (7). For all other problems, go to step (8).
(7) Problem Related to RF Levels
Do not set the tester's POWER switch to OFF if you will adjust the
RF output levels of the UUT as continued from the functional
testing.
Do as follows:
(a) Ignore the instructions on the "POWER OFF" box (Figure 116B),
but click on the "OK" button. You will see the "CONTINUE-END
SELECTION" box (Figure 116C).
(b) Click on the "CONTINUE" button. You will see the "LOG-IN"
dialog box (Figure 1113) again with the "NEXT" button enabled.
(c) Go to Fault Isolation (5.).
T&FI-2
Page 144
Feb 20/2002
Matsushita Avionics Systems Corporation
COMPONENT MAINTENANCE MANUAL
PART NUMBER RD-AA5002 SERIES
23-32-47
(8) Other Problems
Do as follows:
(a) Set the tester's POWER switch to OFF, then click on the "OK"
button. You will see the "CONTINUE-END SELECTION" box (Figure
116C).
(b) Click on the "CONTINUE" button. You will see the "LOG-IN"
dialog box (Figure 1113) again with the "NEXT" button enabled.
(c) Go to Fault Isolation (5.).
T&FI-2
Page 145
Feb 20/2002
Matsushita Avionics Systems Corporation
COMPONENT MAINTENANCE MANUAL
PART NUMBER RD-AA5002 SERIES
23-32-47
5. Fault Isolation
A. Preparations for Fault Isolation
(1) Disassembly Necessary for Fault Isolation
(a) If the problem is related to the RF levels (too high or too low)
and if you think you can correct the problem through
adjustments, go to step (b). For all other problems, go to step
(c).
(b) Disassembly for Adjustments
1 Keep the tester's POWER switch ON.
2 Remove the top cover assembly [1-10].
(c) Disassembly for Fault Isolation
1 Set the tester's POWER switch to OFF.
2 Remove the top cover assembly [1-10] and bottom cover [1-35].
(2) General Sequence of Fault Isolation, Repair and Functional Testing
Functional testing of the UUT must be completed with the general
result as "PASS". Figure 133 shows the general sequence of fault
isolation, repair and functional testing.
You usually do manual checks after the repair to make sure if the
problem is corrected. Manual checks are possible in the adjustment
mode. Refer to B. below for the adjustment mode.
T&FI-2
Page 146
Feb 20/2002
Matsushita Avionics Systems Corporation
COMPONENT MAINTENANCE MANUAL
PART NUMBER RD-AA5002 SERIES
23-32-47
START OF
FAULT ISOLATION
FAULT ISOLATION
REPAIR
MANUAL CHECK
PROBLEM
CORRECTED?
NO
FUNCTIONAL TESTING
GENERAL RESULT?
UUT SERVICEABLE
YES
PASS
FAIL
GENERAL SEQUENCE OF FAULT ISOLATION, REPAIR AND FUNCTIONAL TESTING
Figure 133
T&FI-2
Page 147
Feb 20/2002
Matsushita Avionics Systems Corporation
COMPONENT MAINTENANCE MANUAL
PART NUMBER RD-AA5002 SERIES
23-32-47
B. Adjustment Mode
In the adjustment mode, the tester program lets you do manual checks and
manual setting of the modulator frequencies.
The procedure to use the adjustment mode is given below. The procedure
starts from the "LOG-IN" dialog box (Figure 113) with the "NEXT" button
enabled.
IMPORTANT
Do not obey the instruction given on the "POWER OFF" box (Figure 116B).
ALWAYS KEEP THE TESTER'S POWER SWITCH ON UNTIL YOU COMPLETE THE
 
中国航空网 www.aero.cn