曝光台 注意防骗
网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
28-20 S / N 731 - 9999 200 300 hrs or
14) Clean or replace the filtering element of the fuel selector, check the support - refer to 28-20-02 201. 1 year
30-10 S / N 1 - 9999 200 5 years
15) Remove cover plate 244L and inspection door 216C, slightly lift and hold the de-icing system tank (if installed).
Inspect the inner face of the fuselage skin under the tank for corrosion.
Install tank, cover plate and inspection door - refer to 30-09-90 301.
30-10 16) Check the de-icing system (if installed) - refer
to 30-09-90 301. 200
32-30 17) Visually inspect the landing gear hydraulic generator and check for leaks. Check fluid level - refer to 12-13-03301. 200
32-30 18) Check the brushes of the PRESTOLITE hydraulic generator for condition. 200 1000 hrs
32-30 19) Perform an overhaul and a bench test of the 200 2000 hrs
PRESTOLITE hydraulic generator.
32-30 20) Replace the LHC hydraulic generator seals. 200 5 years
32-30 21) Perform an overhaul of the LHC hydraulic generator. 200 7500 hrs or
15 years
32-30 22) Visually inspect the landing gear hydraulic system tubes for evidence of leaks and wear ; check the routing ; check the attach fittings and the unions for condition and interference. 200 500 hrs
34-10 23) In case of frequent flights in highly humid atmosphere, drain the normal static pressure system and (if installed in rear fuselage) the emergency system - refer to 200
34-11-00 201.
34-10 24) Perform a tightness test on air data systems and check
the associated instruments - refer to 34-11-00 201. 200 300 hrs or
3 years
35-00 25) Inspect the oxygen cylinder (if installed) for sealing,
corrosion and distortion (swelling, crushing), attachment and hydrostatic test expiration. 200
35-00 26) Visually inspect the oxygen system (if installed). 200 2 years
Thoroughly inspect and disinfect the masks.
Perform an operational test - refer to 35-00-00 201.
AIM
Validity : S / N 1 - 9999 05-20-04 (JA) Page 205
JUN 01
ATA "4A" INSPECTION - 100 HOURS
COCKPIT AND FUSELAGE INSPECTION (AREA 200) AREA OTHER
INSPECTION PERFORMED
BY
35-00 27) Perform a hydrostatic test of the EROS oxygen cylinder (if installed). 200 3 years
35-00 28) Perform a hydrostatic test of the PURITAN BENNETT oxygen cylinder (if installed). 200 3 years or
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:TB 20 MAINTENANCE MANUAL 05 TIME LIMITS MAINTENANCE CHECKS TB20飞机维护手册 05 时间限制维护检查 2(8)