曝光台 注意防骗
网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
ailerons and stabilizers. If doubtful, check continuity and resistance - refer to 23-60-00 201.
24-00 4) Visually inspect all cable connections in the L.H. wing. 500
Replace cables if damaged. Inspect cables for routing, clamp security, lugs and cleanliness.
27-10 5) Visually inspect the roll control linkage in L.H. wing, inspect bellcranks, attaching hardware, check play, look for wear, interference and corrosion - refer to 27-10-00 201. 500
27-50 6) Visually inspect (do not remove) the L.H. flap control rods. 500
27-50 7) Remove and clean the L.H. flap control bellcrancks. 500 1000 hrs
Perform a detail examination. Lubricate. Install.
27-50 8) Visually inspect (do not remove) the flap control linkage for security of attach fittings, play, evidence of wear, interference and corrosion - refer to 27-50-01 201. 000 1000 hrs
27-30 9) Visually inspect the stall warning device, check attach fittings and connectors - refer to 27-30-04 201. 500
28-10 10) Perform an operational test of the L.H. fuel tank cap and check the seal condition - refer to 28-10-00 301. 500
12-10 11) Drain the fuel tanks and fuel system - refer to 000
12-11-02 301. Ventilate - refer to 12-11-03 301.
28-10 12) Inspect the L.H. fuel tank for condition - refer to 500
28-10-00 601.
28-10 13) Inspect the draining holes located on the non-sealed ribs of the L.H. fuel tank for partial or total obstruction with sealing compound or any other deposit. 500
28-10 14) Inspect the draining holes located under the low level detector box (if installed) of the L.H. fuel tank for partial or total obstruction with sealing compound or any other deposit. 500
28-10 15) Visually inspect the L.H. fuel tank air vent pipes for condition, security and obstruction. 500
AIAA
Validity : S / N 1 - 9999 05-20-05 (JA) Page 218
JUN 01
ATA "80A" MAJOR INSPECTION
L.H. WING INSPECTION AREA 500) AREA OTHER
INSPECTION PERFORMED
BY
28-20 16) Visually inspect the fuel outlet union on the L.H. wing ; check the line, the support and the grommet ; clean the strainer - refer to 28-20-03 201. 500
28-40 17) Remove the L.H. tank float gages (if installed). 500
Check the floats for porosity and travel, check the tracks and the seal for condition.
Install the float gages - refer to 28-40-01 401.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:TB 20 MAINTENANCE MANUAL 05 TIME LIMITS MAINTENANCE CHECKS TB20飞机维护手册 05 时间限制维护检查 2(34)