Inspection cellule Airframe inspection
Inspection electrique Electrical inspection
-I I
Preliminary inspection
Figure 201
ABAA
Validity : S / N 1 - 9999 05 30 02Page 205
(CA) JUN 01
Landing gear lever DOWN
"Alternate Air" (if installed) Pushed
Manifold pressure Check equal to atmospheric pressure
(Pat) less 50 hPa (1.5 in. Hg)
Alternate static source (if installed) PUSHED
Air conditioning (if installed) OFF
3. ENGINE STARTING
Main switch ON
Oil pressure warning light Illuminated
Parking brake warning light Illuminated
Anti-collision lights (if installed) ON
A. Cold engine procedure
Propeller FULL FORWARD
Throttle 1/4 OPEN
Mixture IDLE CUT-OFF
Fuel pump ON
Pump warning light Illuminated
Mixture FULL RICH until fuel flow is displayed
(3 to 5 sec.) then IDLE CUT-OFF
Fuel pump OFF
Area Clear
Magneto / start selector START (30 sec. maxi)
When the engine starts :
Magneto selector BOTH
Mixture FULL RICH
Oil pressure Green sector
If no oil pressure indication after 30 sec.,
shut down engine.
B. Hot engine procedure
Propeller FULL FORWARD
Throttle FULL POWER
Mixture IDLE CUT-OFF
Fuel pump ON
Mixture FULL RICH during 1 sec.
then IDLE CUT-OFF
Fuel pump OFF
Area Clear
Magneto / start selector START (30 sec. maxi)
When the engine starts :
Magneto selector BOTH
Mixture FULL RICH
Throttle REDUCED
ABAA
Validity : S / N 1 - 9999 05 30-02Page 206
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:TB 20 MAINTENANCE MANUAL 05 TIME LIMITS MAINTENANCE CHECKS TB20飞机维护手册 05 时间限制维护检查 2(78)